REPORT OF PIER OBSERVATION
Security Fire Systems
196 S. Freeport Parkway
Coppell, Texas
REPORTED TO: Security Fire Systems, Inc.
196 Freeport Parkway
Coppell, Texas 75019
ATTN: Mr. Mike Alexander
REPORT NO. 21
REPORT DATE: 06-12-17
REG PROJECT NO. 21753
TECHNICIAN: D. Decuir
PAGE: 1 of 1
CONTRACTOR: Trest Construction
Date
Pier No.
Shaft
Size
(inches)
Required
Penetration
(feet)
Depth to
Stratum
(feet)
Total Depth
of Pier
(feet)
Actual
Penetration
(feet)
Concrete
Length
(feet)
06-08-17 E-3 24 5.0 13.0 18.6 5.0 N/A
D-3 24 5.0 14.6 20.1 5.5 N/A
Reinforcing Steel: 24” 6 #6 bars with #3 ties at 12 inches O.C.
Note: Piers were backfilled
E-Mail
Distribution: (1) Security Fire Systems, Inc./
Mr. Mike Alexander
(1) GPF Architects, LLC/Mr. Greg Frnka
(1) Trest Construction/Mr. Gilbert Trevino
(1) City of Coppell/Mr. Matthew Mabry
(1) Trest Construction/
Mr. Clement Wang
(1) Trest Construction/Mr. Eric Larsen
Submitted by:
REED ENGINEERING GROUP, LTD.
Registration Number F-3114
Bill Woowline
Sr. Manager, CMT
BW/sp