Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Security Fire Systems-LR170614
2424 STUTZ DR. SUITE 400 DALLAS, TX 75235 TEL [214] 350 5600 FAX [214] 350 0019 . REPORT OF PIER OBSERVATION Security Fire Systems 196 S. Freeport Parkway Coppell, Texas REPORTED TO: Security Fire Systems, Inc. 196 Freeport Parkway Coppell, Texas 75019 ATTN: Mr. Mike Alexander REPORT NO. 22 REPORT DATE: 06-14-17 REG PROJECT NO. 21753 TECHNICIAN: D. Decuir PAGE: 1 of 1 CONTRACTOR: Trest Construction Date Pier No. Shaft Size (inches) Required Penetration (feet) Depth to Stratum (feet) Total Depth of Pier (feet) Actual Penetration (feet) Concrete Length (feet) 06-12-17 A.4-1.0 24 5.0 15.0 20.2 5.0 17.8 A.7-1.0 24 5.0 15.0 20.0 5.0 17.6 B.2-1.0 24 5.0 15.0 20.0 5.0 17.6 B.4-1.0 24 5.0 17.5 23.1 5.6 20.7 C.1-1.0 24 5.0 16.5 22.3 5.8 19.9 C.5-1.0 24 5.0 16.2 24.0 7.8 21.6 D.1-1.0 24 5.0 18.6 25.1 6.5 22.7 E-1.0 24 5.0 16.8 22.8 6.0 20.4 E.7-1.0 24 5.0 16.4 22.5 6.1 20.1 F-1.6 24 5.0 15.3 23.0 7.7 20.6 D.6-1.0 24 5.0 17.4 24.3 6.9 21.9 Reinforcing Steel: 24” 6 #6 bars with #3 ties at 12 inches O.C. Note: All piers required use of temporary casing. E-Mail Distribution: (1) Security Fire Systems, Inc./ Mr. Mike Alexander (1) GPF Architects, LLC/Mr. Greg Frnka (1) Trest Construction/Mr. Gilbert Trevino (1) City of Coppell/Mr. Matthew Mabry (1) Trest Construction/ Mr. Clement Wang (1) Trest Construction/Mr. Eric Larsen Submitted by: REED ENGINEERING GROUP, LTD. Registration Number F-3114 Bill Woowline Sr. Manager, CMT BW/sp