Security Fire Systems-LR170612 (3) 2424 STUTZ DR.  SUITE 400  DALLAS, TX 75235  TEL [214] 350 5600  FAX [214] 350 0019 REPORT OF FIELD DENSITY TESTS Security Fire Systems 196 S. Freeport Parkway Coppell, Texas REPORTED TO: Security Fire Systems, Inc. 196 Freeport Parkway Coppell, Texas 75019 ATTN: Mr. Mike Alexander REPORT NO. 19 REPORT DATE: 06-12-17 REG PROJECT NO. 21753 TECHNICIAN: J. Castaneda PAGE: 1 of 1 CONTRACTOR: Trest Construction Proctor No. ASTM Standard Description Optimum Moisture, % Maximum Density, PCF 8 D-698 Brown clay (lime-treated) 19.2 101.8 Test No. Date Location Depth Below Final S. G. (feet) Pocket Pen (tsf) Field Density (pcf) Field Moisture (%) Proctor ID Compaction Level (%) 158 06-02-17 Paving: STA 1+00 0.0 3.75 98.5 20.8 8 96.8 159 Paving: STA 3+00 0.0 3.75 97.2 21.3 8 95.5 160 Paving: STA 5+00 0.0 4.0 99.9 20.7 8 98.1 161 Paving: STA 6+50 0.0 4.0 99.8 20.9 8 98.0 Comments: Where tested, materials were in compliance with project specifications. Note: Locations are referenced from water line station numbers. E-Mail Distribution: (1) Security Fire Systems, Inc./ Mr. Mike Alexander (1) GPF Architects, LLC/Mr. Greg Frnka (1) Trest Construction/Mr. Gilbert Trevino (1) City of Coppell/Mr. Matthew Mabry (1) Trest Construction/Mr. Clement Wang (1) Trest Construction/Mr. Eric Larsen Submitted by: REED ENGINEERING GROUP, LTD. Registration Number F-3114 Bill Woolwine Sr. Manager, CMT BW/sp