Security Fire Systems-LR170612 (3)
2424 STUTZ DR. SUITE 400 DALLAS, TX 75235 TEL [214] 350 5600 FAX [214] 350 0019
REPORT OF FIELD DENSITY TESTS
Security Fire Systems
196 S. Freeport Parkway
Coppell, Texas
REPORTED TO: Security Fire Systems, Inc.
196 Freeport Parkway
Coppell, Texas 75019
ATTN: Mr. Mike Alexander
REPORT NO. 19
REPORT DATE: 06-12-17
REG PROJECT NO. 21753
TECHNICIAN: J. Castaneda
PAGE: 1 of 1
CONTRACTOR: Trest Construction
Proctor
No.
ASTM
Standard
Description
Optimum
Moisture, %
Maximum
Density, PCF
8 D-698 Brown clay (lime-treated) 19.2 101.8
Test
No.
Date
Location
Depth
Below
Final S. G.
(feet)
Pocket
Pen
(tsf)
Field
Density
(pcf)
Field
Moisture
(%)
Proctor
ID
Compaction
Level (%)
158 06-02-17 Paving: STA 1+00 0.0 3.75 98.5 20.8 8 96.8
159 Paving: STA 3+00 0.0 3.75 97.2 21.3 8 95.5
160 Paving: STA 5+00 0.0 4.0 99.9 20.7 8 98.1
161 Paving: STA 6+50 0.0 4.0 99.8 20.9 8 98.0
Comments: Where tested, materials were in compliance with project specifications.
Note: Locations are referenced from water line station numbers.
E-Mail
Distribution: (1) Security Fire Systems, Inc./
Mr. Mike Alexander
(1) GPF Architects, LLC/Mr. Greg Frnka
(1) Trest Construction/Mr. Gilbert Trevino
(1) City of Coppell/Mr. Matthew Mabry
(1) Trest Construction/Mr. Clement Wang
(1) Trest Construction/Mr. Eric Larsen
Submitted by:
REED ENGINEERING GROUP, LTD.
Registration Number F-3114
Bill Woolwine
Sr. Manager, CMT
BW/sp