Loading...
9th Grade Center-LR170616 (3)Report Number: Service Date: Report Date: Task: Client Coppell, TX 75019 1301 Wrangler Circle Coppell ISD 9th Grade CenterCoppell ISD Attn: Louis Macias 1303 Wrangler Cir Coppell, TX 75019 214-630-1010 Reg No: F-3272 Dallas, TX 75247-4547 8901 Carpenter Fwy Ste 100 94171164.0042 06/16/17 06/26/17 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Project Project Number: 94171164 Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: F9717DP Martin Marietta Material Information 1044 3222 Plant: Ticket No.: 131 4045268 Field Test Data Test Air Content (%): Result Specification 5 3/4 5 - 7 1.1 0 - 3 94 89 152.4 3,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:06/16/17 1132 Jason Carrizales Clear 10/40 10 1232, 1236Sample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Drilled Piers, see Foundation Observation Report #94171164.0041 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 06/23/17 7 39,880 1 3,170 1 2 4.00 12.57 07/14/17 28 1 3 4.00 12.57 07/14/17 28 1 4 4.00 12.57 07/14/17 28 1 5 4.00 12.57 08/11/17 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) Coppell ISD, Louis Macias (1) Corgan Associates Inc, Keith Cummins (1) Glenn Engineering, Robert Howman (1) Northstar Builders Group, Charles Posey (1) Northstar Builders Group, Jeff Miller (1) Northstar Builders Group, Justin Dunkin (1) Northstar Builders Group, Roberto Gonzalez (1) Sizelove Construction, Nathan Hayward Daniel Wood Project Manager Northstar Builders Group, LLC Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Jason Carrizales The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1CR0001, 11-16-12, Rev.6