Security Fire Systems-LR170623
2424 STUTZ DR. SUITE 400 DALLAS, TX 75235 TEL [214] 350 5600 FAX [214] 350 0019
REPORT OF PIER OBSERVATION
Security Fire Systems
196 S. Freeport Parkway
Coppell, Texas
REPORTED TO: Security Fire Systems, Inc.
196 Freeport Parkway
Coppell, Texas 75019
ATTN: Mr. Mike Alexander
REPORT NO. 30
REPORT DATE: 06-23-17
REG PROJECT NO. 21753
TECHNICIAN: D. Decuir
PAGE: 1 of 1
CONTRACTOR: Trest Construction
Date
Pier No.
Shaft
Size
(inches)
Required
Penetration
(feet)
Depth to
Stratum
(feet)
Total Depth
of Pier
(feet)
Actual
Penetration
(feet)
Concrete
Length
(feet)
06-20-17 D-2.0 24 5.0 17.0 22.5 5.5 22.5
E-2.0 24 5.0 15.0 20.5 5.5 20.5
F-1.4 24 5.0 14.0 19.0 5.0 14.0
E.9-1.2 24 5.0 16.1 21.1 5.0 16.1
Reinforcing Steel: 24: 6 #6 vertical bars with #3 ties at 12 inches O.C.
Note: All piers required use of temporary casing.
E-Mail
Distribution: (1) Security Fire Systems, Inc./
Mr. Mike Alexander
(1) GPF Architects, LLC/Mr. Greg Frnka
(1) Trest Construction/Mr. Gilbert Trevino
(1) City of Coppell/Mr. Matthew Mabry
(1) Trest Construction/
Mr. Clement Wang
(1) Trest Construction/Mr. Eric Larsen
Submitted by:
REED ENGINEERING GROUP, LTD.
Registration Number F-3114
Bill Woowline
Sr. Manager, CMT
BW/mg