Security Fire Systems-LR170623 2424 STUTZ DR.  SUITE 400  DALLAS, TX 75235  TEL [214] 350 5600  FAX [214] 350 0019 REPORT OF PIER OBSERVATION Security Fire Systems 196 S. Freeport Parkway Coppell, Texas REPORTED TO: Security Fire Systems, Inc. 196 Freeport Parkway Coppell, Texas 75019 ATTN: Mr. Mike Alexander REPORT NO. 30 REPORT DATE: 06-23-17 REG PROJECT NO. 21753 TECHNICIAN: D. Decuir PAGE: 1 of 1 CONTRACTOR: Trest Construction Date Pier No. Shaft Size (inches) Required Penetration (feet) Depth to Stratum (feet) Total Depth of Pier (feet) Actual Penetration (feet) Concrete Length (feet) 06-20-17 D-2.0 24 5.0 17.0 22.5 5.5 22.5 E-2.0 24 5.0 15.0 20.5 5.5 20.5 F-1.4 24 5.0 14.0 19.0 5.0 14.0 E.9-1.2 24 5.0 16.1 21.1 5.0 16.1 Reinforcing Steel: 24: 6 #6 vertical bars with #3 ties at 12 inches O.C. Note: All piers required use of temporary casing. E-Mail Distribution: (1) Security Fire Systems, Inc./ Mr. Mike Alexander (1) GPF Architects, LLC/Mr. Greg Frnka (1) Trest Construction/Mr. Gilbert Trevino (1) City of Coppell/Mr. Matthew Mabry (1) Trest Construction/ Mr. Clement Wang (1) Trest Construction/Mr. Eric Larsen Submitted by: REED ENGINEERING GROUP, LTD. Registration Number F-3114 Bill Woowline Sr. Manager, CMT BW/mg