9th Grade Center-LR170708FIELD DENSITY TEST REPORT
Report Number:
Service Date:
Report Date:
Task:
94171164.0080
07/08/17
07/12/17
8901 Carpenter Fwy Ste 100
Dallas, TX 75247-4547
214-630-1010 Reg No: F-3272
Client
Coppell ISD
Attn: Louis Macias
1303 Wrangler Cir
Coppell, TX 75019
Coppell ISD 9th Grade Center
1301 Wrangler Circle
Coppell, TX 75019
Project
Project Number: 94171164
Lab Test Data
(%)
Compaction
Project Requirements
(%)
Content
Water
No.
Mat.
Material Information
Density
Max. Lab
(%)
Content
Water
Optimum
Ref. No.
Proctor Laboratory
Classification and Description (pcf)Test Method
92-98>/= +4192.723.394171164.0002 Dark brown clay ASTM D698
Field Test Data
No.Test Location Elev.No.
Test Lift /Mat.Depth Density
Probe Wet
Content
Water
(%)
Content
Water
Density
Dry
(%)
Percent
Compaction
(in)(pcf)(pcf)(pcf)
Exterior Grade Beam
34 HA/H6.8 2' BFG 1 6 112.5 24.9 28.4 87.6 94
35 HA/H6.8 1' BFG 1 6 112.8 24.4 27.6 88.4 95
36 HA/H2.5 2' BFH 1 6 112.0 24.4 27.9 87.6 94
37 HA/H2.5 1' BFG 1 6 111.4 24.4 28.0 87.0 94
38 HB.5/H2 2' BFG 1 6 111.7 25.3 29.3 86.4 93
39 HB.5/H2 1' BFG 1 6 113.1 25.8 29.6 87.3 94
40 HA/H7.9 Final 1 6 112.2 25.2 29.0 87.0 94
41 HA/H2.7 Final 1 6 110.8 24.5 28.4 86.3 93
42 HB.7/H2 Final 1 6 113.0 25.6 29.3 87.4 94
Comments:
Datum:BFG = Below final grade Serial No:72498
Test and/or retest results on this report meet project requirements as noted above.
Perform in-place density and moisture content tests to determine degree of compaction and material moisture
condition.
Services:
Reported To:
Contractor:
Charles
Northstar Builders Group, LLC
Daniel Wood
Project Manager
Report Distribution:
See attached distribution list.Reviewed By:
Terracon Rep.: Martinez, Andres
ASTM D6938Test Methods:
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the
actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials.
CR0007, 11-16-12, Rev.7 Page 1 of 1