Fairfield Inn-LR170516CONCRETE COMPRESSIVE STRENGTH TEST REPORT
Report Number: 94161112.0071
Service Date: 05/16/17
Report Date: 07/17/17 Revision 2 - 56 -day results
Client
Northpoint Construction
Attn: Dilip Pranav
8530 Esters Blvd
Irving, TX 75063
Project
Fairfield Inn - Coppell TX
Northpoint Dr at SH 121
Coppell, TX
Project Number: 94I61112
Material Information Sample Informatinn
Specified Strength: 3,000 psi 28 days
Mix ID:
4711
Supplier:
Charley"s
Batch Time:
1008 Plant: 129625
Truck No.:
703 Ticket No.: 544844
Field Test Data
Test
Slump (in):
Air Content (%):
Concrete Temp. (F):
Ambient Temp, (F):
Plastic Unit Wt. (pef):
Yield (Cu. Yds.):
Laboratory Test Data
Result Specification
$ 3-5
5.2 3-6
81
79
148.0
Set
Specimen
Avg Diam.
`b.
11)
(in)
I
1
4.00
I
2
4.00
1
3
4.00
I
4
4.00
4.00
1rerracon
8901 Carpenter Fwy Ste 100
Dallas, TX 75247-4547
214-630-10I0 Reg No:F-3272
Sample Date:.
Sampled By:
Weather Conditions:
Accumulative Yards:
Placement Method:
Water Added Before (gal):
Water Added After (gal):
Sample Location:
Placement Location:
Area Date
Date
(sq in) Received
Tested
12.57
05/~
12.57
06/13/17
12.57
06/13/17
12.57
06/13/17
12.57
07/11/17
05/16/17 Sample Time: 1110
Muthanna Al Ani
Totally cloudy, breezy
10/40 Batch Size (cy): 10
Direct Discharge
0
0
In front of the gate on Nortpoint Dr
Sidewalk @ W side of the site on
Northpoint Dr.; & N side on Hwy 121
Age at
Maximum
Test
Load
(days)
(lbs)
7
42,420
28
47,970
2.8
51,005
28
48,120
Average (28 days)
56
Compressive
Strength Fracture
(Psi) Type
3,380 1
3,820 1
4,060 2
3,830 1
3,900
57,460 4,570 1
Comments: Compressive strength of 56 day cylinders complies with the specified strength.
Samples Made By: Terracon
Services: Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength
samples.
Terracon Rep.: Muthanna Al Ani
Reported To:
Contractor:
Report Distribution:
(1) Northpoint Construction, Dilip Pranay (1) Kenearkey Interests LLC, Jeremy Henicke Reviewed By:
fI) Northpoint Construction, JamicOgden
Senior Project Materials Engineer
Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM 01064, ASTM C1231
The tests were performed in general accordance with applicable ASTM, AASHTO or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the
actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials.
CR0001, 11.16-S 2,Rev.6 Page I of 1