CONFERENCE
REPORT
PROJECT:
ID:MAYS,~, ASSOC.
Quill Corporation
Regional Distribution Center
Coppell, TX
FAX:214-386.;.~78
PAGE
II!
~o ~ o,.. ~ ~-~'i
pl~ Texo~ 7~240
12 ~ ,f,) 38S-0~38
PROJECT NO: 9614
DATE:
June 18, 1996
CONCERNING:
PARTICIPANTS:
City of Coppell Requirements
Tom Morion, Jim Wit, Clay Phillips, Travis
Crump, Creg Jones, Gary Seib.~Ken Gd~in,
Harvey Miller, Terry SchwarUn& Geoqte Kern,
-Jim Mc~lroy,'MJke Peeples~ Mike Mayse
DISCUSSIONS & CONCEUSION$
Meetin$ was convened to dlscur~ Issum with the City of Coppell afl'etOn8 eady stockin8 of the bullding~ Certificate of
Occupancy and partial CertJficale of Occupancy and to resolve'any outstandin8 en~neerln8 Issues. The following was
discussed:
1. It is the desire of Quill Corporation to be shipping product by November of 1996 which will require
~3cklng the building in October. A partial Certificate of Occupancy for the warehout, e would need to be iit~ued
¢n¢~ the entire building would not be completed by this time. The dty would require the following in order to
Issue a partial C.O. for {he warehouse.
A. Fire Lane~ and hydrants to be complete and operational.
B. Fire sprinkler and fire alarm in warehouse to be operational.
C. Inspection and approval by the Bldg Dept and Fire Dep{ prior to receivin8 slx3ck
2 The City requefzed that in order to avoid delays, inspections should be requested one to two months
prior to the date. scheduled to receive stock.
3 If landscapin8 is not in,lied prkx to date of requested occupancy and Owner would like to defer
planting undl sprin& a bond in the amount of 110~ of the cost of landscaping can be posted with the City,
refundable upon completion of the landscapin8 and Irrigation.
4. In order for inspection to occur, Fire splnkler shop. drawings and Fire Alarm System drawings mint be
submitted and approved by the City prior to Installation. ~
The storm sewer Issue was discussed with Ken Griffin, Mike Peeples and Jim McEIroy. The city indicated that the existin8
system was insLalled by the old Municipal Utility Disulct prior to jurisdiction by the City, and does not meet current City
standards. In order to accomodate the addiUonal storm water runoff created by new development~ several ~oluUons and
alternative were discussed that would be acceptable to the City as follows:~r'~
1.
A
parallel pipe system could be Installed to handle he e~cess runoff (rom Quill to the exl~nl~42'~lla
pipe on the property south of Quill.
2. An ear,hen swale could be constucted to conduct the exoes~ runoff form the Quill property to the c~eek
to the south.
3. A combination of the above.
Pa~e 1 of 2
06×i9 '96 07:54 ID:MAYS,~ ASSOC. FAX:214-386,~578 PAGE 3
CONFFREN~ REPORT June 18, 1996
__Qu'il! Corooration /
Quill was to analyze the cost of each option and notify the city of their selected option. The CILy asreed to inve~isate the
possibility of assessin8 an Impact fee on the adjacent property owners to reimbuse Quill in the event that Quill chooses to
improve the eixllJng system with a parallel pipe.
The city considered the earthen swale option as a tempory condition and would require that the existin$ system be
improved with the parallel pipe before the City would 8rant permit approval for the proposed buildin8 expan~on.
These notes, co. nvey.ou..r.understand!n8 of items dlscu~sed and eor~:ludom readted durinli this confeaence.
These conclusions srlall oe ac;r. epto(I as correct unless oUlen~so notlflecl in writing within'ten days.
COPIES TO:
ParUdpants
FILE: 9614
Mike Mayse
®
0
0
[] BY:
Please call if there are any problems With th~ t~ansmlsalon.
06/1.9 '96 07:54 ! D :i,i~YS,,~, pssoc. FCtX: 21zl-386,.~78,
iLI~I lB 'cJ6 14:57 M]~CHP~.iL F~EPtE~ ~ E14-E4B-5747
P~GE
4
Michael Po=pies
June 14, 1996
14850 ~.~ort~m D~Ave
Su/Ce 201
Dallas, Texas ?5240
0~fstce Storm Sewer System
. . Adjacent ~0 che QuiLl Site*aC ...........
Royal Z..ane and Gacevtew Lane
Dear Mike,
Zn reference co 7our request concerning the cos~ of ~he
ons~=e and of£s~e drainage co complete =he project, ye have
made the ~ollowing aSlum~Cions:
The offeite s~o~m li~le c~n be =~ed ~n2o the [nl.et
aC the heed o~ the 4e' e~orm 8ewer, in other wo~fls
no new struc2ure would b~ required.
The hydraulics oaloulatLons will bear sun the
assumptions made. NO conm~dera~i~n hms been made
The costs are a0 £ollows:
1. S~orva Sewer (295 L.F. - ~0#
2. Tie ln~o ~he Ex. S~orm
oo' %*5
~- ,$ubCoC&&
O~ite Line: 1. SCo~ Sewer (480 L.P. - 30" RCP
2. T~e into ~he New Offside
~9tneering and Contingencies:
Combination 0nsice/offsite Line:
15,045
GO0
045
24,480
S00
4~,025'.
4,205
TOTAL ALL COSTS:
$ 46,230
46~0 Sun~t D~as, Texas 75,246
06/'19 '96 07:55 ID:II~YS~ ASSOC. FAX:214-386,,7,,~TS
' J~ 18 '96 14'57, MICHAEL PEEPLES EN~ ~14-E48-3747
PAGE
£OllOvs; I
2. T~o O~gsiCe swale can be gzaded to tie into the
#Ord8 no nov sc~Ac~ure vould be ~equiFed.
3. Tho hydraulics calculations v£11 boar out the
assumptions made. NO conoiderl~ion hal been ua do
pipe ties into in ~heSe calcula~Aon~
O~£si~e Swale~
~. r~xclvation and Shaping 200 1.~. ditch
(~00 c.y. · $30/e.7)
sub,s:al
Ongite Line:
I. Storm Sewer (480
2. Tie in~o the New O~o~to bins
Subtotal
Bngineering and Con~in~encie,;
Co~in&cion'O~ite/O££.lCe Bv&,le:
TOTAL AL~ C09TS:
Please call me 1£ you have &nM questions.
3,000
3,boo
24, &BO
::, .980
i
30,?70
43,03~
MiChael N. Peoples, ~.g'
06/19 '96 07:55 ID:MaYS~ ~SSOC.
, JUN 18 ~9~ 14:58 MImCH~L PEEPLES EMG
FAX: ~ 14-386,,Z,~78
17
P~GE
6
ENGINEERING
DEPAR
P.O. BOX 478
255 PARKWAY BLVD.
COPPELL. TX 75019
FAX NO. (214)
TMENT
FAX
CO VER
SHEET
TO: ~.~
FIRM:
TRANSMITTED BY:
FROM: ~
PHONE NO.:
DATE: {~ '
TIME: (0':
NUMBER OF PAGES (INCLUDING COVER
REMARKS:
SHEET)
IF YOU DO NOT RECEIVE ALL OF THE
PAGES, PLEASE CALL (214.) 304-3679.
ENGINEERING
DEPAR
FAX COVER
P.O. BOX 478
255 PARKWAY BLVD.
COPPELL, TX 7501g
FAX NO. (214) 304-3~70
TMENT
SHEET
FROM: ~___~~__~"%
FIRM:
FAX NO: ~Z ~'~ 3-;~'7
TRANSMITTED BY'
PHONE NO.:
DATE: ~) ' I o) ,~ b
TIME: I '0 '. ~ 0
NUMBER OF PAGES (INCLUDING COVER SHEET)
IF YOU DO NOT RECEIVE ALL OF THE
PAGES, PLEASE CALL (214.) .904-,.9679.