Tax2014D-CS150512 t
City of Coppell Public Works Department
Routing Sheet for Review of Submittals
Vendor Name: I V CeMSAUCYLV —, Date: JZ l I 3--
Contracted Work/Project: DA" rt /PIA C A r
Explanation: Ji j A - S (4.- C (AAA 1 _ Lc
Routing Sequence: Name Initials Date
1. Employee initiating review: Jamie Brierton *ii,
0 Approved Approved As Noted 0 Revise& Resubmit ` ////
Comments: T, 1a3C. SJt2M esletkA ,5. 19 kthr ebek do S
2. Wastewater Supervisor: Billy Williams
0 Approved 0 Approved/As ,.7S. . 0 Revise& Resubmit
Comments:
3. Water Supervisor: Jerry Davis
0 Approved 0 ApproA Wed 0 Revise& Resubmit si
Comments: -'C
5/S
4. Streets Supervisor: Albert SamaniegoiLb nl
l
i'
0 Approved 0 Approved As Noted 0 Revise& Resubmit
Comments:
5. C struction Inspector: Derrick Thomas 10( 1S
pproved 0 Approved As Noted 0 Revise& Resubmit
Comments:
6. A Stant Director of Public Works: Keith Marvin 166--591/3/7(
Approved 0 Approved As Noted 0 Revise& Resubmit
Comments: /`y o f A"CL r A yi4 - el.
Copy to Laserfisch: YES / NO
Copy to Engineer of Record: , YES / NO ('t
Go v T `V11,4
Date: 5/11/2015
RED! MIX CONCRETE No.of pages total: 19
e-mail transmittal
e-mail: candaceAfnhconstruction.com
To: Candace Gillespie
From: Dave Guice
Phone: (469)248-0301 Quality Control Manager
Fax: - 3401 Bethlehem Ave.
Fort Worth,Texas 76111
Phone: (214)674-4774
Fax: (817)759-1716
e-mail: dauice@cowtownrm.us
Remarks: Urgent X For review Reply ASAP Please Comment
* Please acknowledge our request to receive copies of all concrete test reports so that we can update our files.
Please specify mix design numbers when placing the order.
GOVV TOW*
RED! MIX CONCRETE
Portland Cement Concrete Mix Design
Date:May 11, 2015 Mix Design #: 360-1
4 Contractor: FNH Construction LLC
Project: City of Coppell-Denton Tap &MacArthur Reconstruction
Specific Use: Paving
MIX DESIGN PARAMETERS
' Minimum Compressive Strength: 3600 psi @ 28 Days Sack Content: 6.00
Air Content:4.5%+/-1.5% Fly Ash Content: 0%//
2 Slump Range(inches): 4 +l-1"(After the addition of WR Admixtures)
W/Cm Ratio(Ib/Ib): 0.45 (5.08 gal/sk) Theoretical Plastic Unit Weight: 146 pcf
One Cubic Yard Mix Proportions
Materials ASTM Standards Weights per Cubic Absolute
Yard.SSD Volume
Cement ASTM C 150 Type I/II 564 lbs. 2.87 cu.ft.
Coarse Aggregate ASTM C33 Size#57 1" Limestone 1850 lbs. 11.15 cu.ft.
Fine Aggregate ASTM C 33 Concrete Sand 319 lbs. 1.92 cu.ft.
Fine Aggregate ASTM C 33 Bridgeport Sand 951 lbs. 5.77 cu.ft.
Admixture 1 ASTM C 494 Type A(NRWR) 5.0 oz./cwt. 28.2 oz.
Admixture AEA ASTM C 260 AEA 0.3 oz./cwt. 1.7 oz.
Water ASTM C94 30.5 gal. 254 lbs. 4.07 cu.ft.
Air Void 1.22 cu.ft.
27.00 cu.ft.
This design will meet or exceed design strengths when tested and evaluated in accordance with applicable ASTM test methods and standards,and when conc
is placed and cured using recommended construction practices. Only strength specimens molded and initially cured per Sec.10 ASTM C 31-03a will be
considered for acceptance,in accordance with ACI 318 Sec.5.6.
'Slump achieved after the addition of water-reducing admixtures.
3Admixture dosages will vary,depending on average concrete temperatures and specific job conditions.
'Please add Cow Town Redi Mix to the distribution list to receive copies of all concrete test reports,per ACI 318 Chapter 5.
P.O.Box 162327 Office:(817)759-1919
Dispatch:(817)759-2599 Fort Worth,TX 76161 Fax(817)759-1716
cow Tow,?
-' Field Test Data Mix No. 360-1 Basis for Selection
RED!MIXCONCRETE
Contractor: Various ACI 318,Section 5.3.2.1(5-2)
Project: Various Design Strength: 3600 psi Standard Deviation: 688 psi
Data Represents: 54 Tests Required Strength: 4702 psi
Laboratory: Various Data Updated: 5/11/2015 Average Strength: 5217 psi
Conc. Unit 7 Day Compressive 28 Day Compressive Strength Data
4 Date Slump Temp Air% Weight Cyl.1 Cyl.2 7 Day Avg. Cyl.1 Cyl.2 SetAvg Avg./3 Range St.Dev. RunAvg 56 Day
1 07/14/2014 5.25 97 3.00 3920 3920 4880 4950 4920 4920 70 4920
2 07/16/2014 5.00 96 3.60 3770 3770 4850 4880 4870 4900 30 35 4900
3 07/16/2014 4.50 94 6.70 3500 3500 4640 4590 4620 4800 50 161 4800
4 07/24/2014 5.50 87 6.10 3260 3260 4760 4920 4840 4780 160 133 4810
5 08/19/2014 4.50 92 3.90 3810 3810 4860 4860 4860 4770 0 117 4820 5690
6 08/29/2014 3.50 86 3.80 4070 4070 4880 4750 4820 4840 130 104 4820 5400
7 08/29/2014 4.00 87 3.10 4510 4510 5140 5370 5260 4980 230 191 4880 5450
8 09/11/2014 2.75 78 4230 4230 5830 5660 5750 5280 170 354 4990 5390
9 09/12/2014 4.75 77 2960 2960 3870 4190 4030 5010 320 461 4890
10 09/24/2014 5.75 84 3260 3260 4300 4060 4180 4650 240 488 4820 4750
11 09/29/2014 4.50 76 4.80 3690 3690 4930 5030 4980 4400 100 466 4830
12 09/29/2014 5.00 76 4.60 3960 3960 5410 5350 5380 4850 60 472 4880
13 10/09/2014 4.50 87 4.90 3350 3350 5210 5250 5230 5200 40 462 4900
14 10/09/2014 4.50 87 4.00 3890 3890 5380 5300 5340 5320 80 459 4930
15 10/09/2014 5.00 88 4.20 3590 3590 4970 4890 4930 5170 80 443 4930
16 10/09/2014 5.00 88 4.90 3910 3910 5410 5330 5370 5210 80 441 4960
17 10/23/2014 6.50 80 3.80 3940 3940 5220 5520 5370 5220 300 439 4990 5850
18 10/24/2014 2.25 82 4.00 4160 4160 5180 5190 5190 5310 10 428 5000 16280
19 11/05/2014 4.50 62 3.50 4110 4110 5130 4720 4930 5160 410 416 4990 5350
20 11/07/2014 5.00 65 5.00 3870 3870 5160 4500 4830 4980 660 407 4990 5660
21 11/11/2014 4.00 62 5.10 3750 3720 3740 4760 4660 4710 4820 100 401 4970
22 11/19/2014 4.00 60 4.50 4140 4140 5410 5360 5390 4980 50 401 4990 5670
23 11/27/2014 5.00 56 4.40 3810 3810 5040 5020 5030 5040 20 392 4990 5590
24 11/29/2014 4.75 65 4410 4410 5670 5570 5620 5350 100 405 5020 6190
25 12/03/2014 4.75 59 3220 3440 3330 4250 4370 4310 4990 120 421 4990
26 12/03/2014 5.00 61 3.80 3460 3460 4990 4400 4700 4880 590 416 4980 i
27 12/03/2014 3.00 64 2.50 3640 3640 4370 4240 4310 4440 130 428 4950
28 12/05/2014 4.50 67 5.10 3460 3630 3550 4580 4690 4640 4550 110 424 4940
29 12/06/2014 5.00 62 5.40 3620 3650 3640 4720 4380 4550 4500 340 423 4930
30 12/15/2014 5.50 59 4.30 3950 4130 4040 5160 4590 4880 4690 570 415 4930
31 12/17/2014 6.25 52 3.80 4010 4000 4010 5080 5260 5170 4870 180 411 4940
32 12/29/2014 6.50 55 4.00 3510 3700 3610 4390 4580 4490 4850 190 412 4920
33 12/22/2014 5.00 60 1.50 3450 3450 4160 4050 4110 4590 110 429 4900
34 12/22/2014 4.00 57 4.50 3510 3510 4570 4850 4710 4440 280 424 4890 5140
35 12/22/2014 5.00 66 3.00 3500 3500 4650 4740 4700 4510 90 419 4890
36 01/05/2015 4.00 46 4.00 3960 3960 4960 4990 4980 4800 30 413 4890
37 01/06/2015 6.50 50 3.00 3740 3740 4900 4820 4860 4850 80 407 4890
38 01/15/2015 6.50 47 4.00 3680 3680 4940 4970 4960 4930 30 402 4890
39 01/22/2015 4.00 43 4.00 4100 3880 3990 5280 5460 5370 5060 180 404 4900
40 01/23/2015 3.50 46 3.20 4330 4420 4380 6600 6560 6580 5640 ' 40 479 4940
41 02/10/2015 6.50 65 1.70 3830 3790 3810 5170 5260 5220 5720 90 475 4950
42 02/10/2015 4.50 66 3.80 4330 4130 4230 5410 5670 5540 5780 260 478 4970
43 02/19/2015 5.00 53 4.00 4490 4490 5000 5300 5150 5300 300 473 4970 5370
44 02/25/2015 5.75 42 4820 4810 4820 6730 6370 6550 5750 360 525 5010
45 02/26/2015 6.00 40 5.25 4440 4440 5930 5870 5900 5870 60 536 5030
46 03/04/2015 5.00 45 5.75 4460 4460 6010 5960 5990 6150 50 548 5050
47 03/16/2015 5.00 67 4.00 5020 5020 6660 6580 6620 6170 80 589 5080
48 03/19/2015 4.50 65 4.25 5450 5450 7080 7020 7050 6550 60 648 5120
49 03/19/2015 6.00 70 3.25 4680 4680 6360 6400 6380 6680 40 666 5150
so 03/23/2015 4.50 70 3.00 4790 4790 6440 6550 6500 6640 110 687 5170
51 03/23/2015 4.50 72 3.10 4770 4770 6280 6190 6240 6370 90 696 5190
52 03/25/2015 4.50 75 3.30 4380 4380 6140 6030 6090 6280 110 700 5210
53 03/27/2015 5.00 65 4.00 4470 4470 5400 5470 5440 5920 70 694 5220
54 03/27/2015 4.00 67 4.20 4000 4000 5250 5320 5290 5610 70 688 5220
Cow Town Redi Mix Concrete Field Test Data for Mix 360 2014-15 xis 1
2580 Wald Road
New Braunfels,TX 78132 CEMENT E
Adiri
CC-ME- Telephone(210)250-4100 MILL
FAX(210)250-4044
Customer Service TEST .
TXDOT MPL#99332 Telephone(800)492-9004 REPORT
Material#1442809 FAX(210)250-4153
Cement Identified as: Balcones Type I,Type II Low Alkali Date of Report:01/01/2015
Plant: CEMEX Cement of Texas, LP Beginning Production Date: December 1,2014
Location: New Braunfels,TX Ending Production Date: December 31,2014
CHEMICAL REQUIREMENTS Spec.Limit TYPE I TYPE II TEST
(ASTM C-114) (ASTM C-150) Low Alkali Low Alkali RESULTS
Silicon Dioxide(Si02),% Min --- --- 20.4
Aluminum Oxide(A1203), % Max --- 6.0 4.6 _
Ferric Oxide(Fe203),% Max --- 6.0 3.4
Calcium Oxide(CaO), % --- --- --- 64.6
Magnesium Oxide(MgO),% Max 6.0 6.0 1.1
Sulfur Trioxide(S03),% * Max 3.0 3.0 2.8
Loss on Ignition(LOI), % Max 3.0 3.0 2.2
Insoluble Residue(IR),% Max 0.75 0.75 _ 0.23
Free Lime,% --- --- 1.5
Alkalies(Na20 equivalent),% Max 0.60 0.60 0.55
Na20 Equ.@ 95%Confidence Level --- --- --- 0.55+/-0.02 _
CO2 in Cement,% --- --- --- 1.32
Limestone in Cement, % Max 5.0 5.0 1.75
CaCO3 in Limestone,% Min 70 70 94
Inorganic Processing Addition,% ** Max 5.0 5.0 2.21
POTENTIAL PHASE COMPOSITION***
Tricalcium Silicate(C3S),% _ Max --- --- 56
Tricalcium Aluminate(C3A), % Max --- 8 6
Heat Index,C3S+(4.75 C3A) Max 100 100 86
PHYSICAL REQUIREMENTS
(ASTM c-204) Blaine Fineness,m2/kg Min 280 280 397
(ASTM C-191) Time of Setting (Vicat)
Initial Set, mins Min 45 45 106
Final Set,mins Max 375 375 185
(ASTM C-266) Time of Setting (Gillmore)
Initial Set, mins Min 60 60 151
Final Set,mins Max 600 600 211
(ASTM C-185) Air Content,% Max 12 12 7.5
(ASTM C-151) Autoclave Expansion, % Max 0.80 0.80 0.03
(ASTM C-109) Compressive Strength
1-Day, psi --- --- --- 2260
3-Day, psi Min 1740 1450 3840
7-Day, psi Min 2760 2470 4770
(Previous)28-Day,psi --- --- --- 6010
(ASTM C-186) Heat of Hydration(7-Day),cal/g Test result is provided for information only 82
*The performance of CEMEX Type I LA, Type II LA has proven to be improved with sulfur trioxide levels in excess of the 3.0%limit for Type II.
Note Din ASTM C-150 allows for additional sulfate,provided expansion as measured by ASTM C-1038 does not exceed 0.020%.
** This cement contains processing additions which meet the requirements of ASTM C-465.Compliance documents are available upon request.
Additional data for the Inorganic Processing Addition is located on page 2 of this certification.
*** Potential Phase Composition adjusted per A1.6.
CEMEX hereby certifies that this cement meets or exceeds the chemical and physical specifications of.
[X] ASTM C-150 for Type I Low Alkali -
[X] ASTM C-150 for Type II Low Alkali '_ i • -
By:
Quality Control Manager
CEMEX-Balcones Cement Plant
2580 Wald RoadArrOCEMENT
X New Braunfels,TX 78132
� �� Telephone(210)250-4100 MILL
FAX(210)250-4044
Customer Service TEST
Telephone(800)492-9004 REPORT
FAX(210)250-4153
Cement Identified as: Balcones Type I,Type II Low Alkali Date of Report:01/01/2015
Plant: CEMEX Cement of Texas, LP Beginning Production Date: December 1,2014
Location: New Braunfels,TX Ending Production Date: December 31,2014
ADDITIONAL DATA
Inorganic Processing Addition
Type Bag House Dust
Silicon Dioxide(Si02),% 12.6
Aluminum Oxide(AI2O3),% 3.8
Ferric Oxide(Fe2O3), % 1.4
Calcium Oxide(CaO), % 82.7
Sulfur Trioxide(SO3),% 0.6
Base Cement Phase Composition
C3S,% 58
C2S,% 16
C3A,% _._ 6
C4AF,% 11
CEMEX hereby certifies that the above described data represents the materials used in the cement manufactured during the
production period indicated.
C.
�'I , 4
By: .
Quality Control Manager
CEMEX-Balcones Cement Plant
0
N
N-
O ,.p
P. N M O O
* O
It
.1..1 Q)
Cn N
CI e4 V) O - N 0
cisu
u
6.1CU
w
Ni...
0
c.
i5 cd
U c
tIO CD a)
all IDD
i-1 `}v,/� H esi o in VD in
VD N I
/ gio 66 U
4I..)
C o
d - a\ oN a au
r-I O\ ON ON V 2
O 0 6tip
U a
.,
H
in o 0 0 0 0
„ , —1 — .--i .-- A
U
CV
4
0
00 0 0 0 0 0 O 0 0 0 0
rl U
O
`�
04 v
d a,
tL p,i 0 N
sanaIs �u!ssed;uaaJad an►;e�nwnD cA .�
iiki w
JJH
DA
VI
.0 lIff ..X „,
g
q
0 f ce U
,
" Hanson
HE DELOCRO(.trM1Nt.lioup
Hanson Aggregates
Southwest Region
Technical Services Lab
1000 N.MacArthur Blvd.
Grand Prairie,TX 75050
Tel. 972-260-3646
Fax. 972-260-3655
www.hansonplc.com
MATERIALS EVALUATION
Coarse Aggregates
Source: Hanson @ Bridgeport(Perch-I lilt) Plant Technical Services
ft777
Type: ASTM 1157(I"-1t4) Crushed Lime Stone Report: 2015-777
Lab NO: TS-Weekly-15 Date:02-28-I5
Date: Received: 02-01-15
ASTM TEST TEST ASTM C-33
METHOD DESCRIPTION RESULTS Specification
C-136 2" Sieve 100 %Passing --------
C-136 1-1/2"Sieve 100 %Passing 100
C-136 1" Sieve 99 %Passing 95-100
C-136 3/4" Sieve 80 %Passing
C-136 1/2" Sieve 45 %Passing 25-60
C-136 3/8" Sieve 34 %Passing
C-136 #4 Sieve 9 %Passing 0-10
C-136 #8 Sieve 2 %Passing 0-5
C-136 #16 Sieve 2 %Passing --------
C-117 Decant (-#200 Sieve Washed) 1.38 %Passing 1.5%Max.
C-127 Relative Bulk Specific Gravity, SSD 2.663
C-I27 Relative Bulk Specific Gravity, Dry 2,632
C-127 Absorption, 1.0 %
C-29 Unit Weight(Dry Rodded), 104.4 Lbs/Cu.Ft,
C-29 Unit Weight(Dry Loose), 94.1 Lbs/Cu.Ft.
C-29 Voids Content(Dry Rodded), 38.3 %
C-131 L.A.Abrasion, 24.1 %Loss 50% Max.
C-1260 Potential Alkali Reactivity of Aggregates, 0.03 %Exp. 0.1 %Max
C-88 Soundness by Sodium
Sulfate(5 cycles), 2.30 %Loss 12% Max.
C-88 Soundness by Magnesium
Sulfate(5 cycles), 3.90 %Loss 18%Max.
C-I23 Light Weight Pieces, 0,01 % 0.5%Max.
C-142 Clay Lumps and Friable Particles, 0.01 °l03.0%Max. ,
C-25 Calcium Carbonate EQV, 96.0 %
C-25 Acid Insoluble Residue, 4.0 %
D-4791 Flat Particles ,.... 4.1 % v,
D-4791 Elongated Particles 3.4 % �1, 1 A
Note:-Hanson Product Code TX-126 � `
r / .
y
/ ,..;>()..ff-3"-.4-K*.'.:`° l.-.'‘
Varian Babakhanian,P.E.
Technical Services Lab Manager
Our letters,analysis and reports are for the exclusive use of the client to whom they are addressed,apply only to the samples tested andf or inspected and are not necessarily
indicative of the qualities of apparently identical or similar products.This report shall not be reproduced except in fill and with the written approval of IrANSON PLC.
•
0
N
O
M
0< PT4 O O
0 0Op pip Ot
at c/ W M N N N
V1 M o
•� en ,� �, N O O kfi l
tri c; esi e4 g
al ,4 1 U
Q
0 H CA O
N ;. Tani O ,O O N N
ct �/]
N tO
Q) Ca, L'u 0/ On M oN N GL
•— N b1� 4 E
bA - c.) c
CU en rn
Ct •M� r, It VD N M X
}C� W CA
CII
x
by o In In VD on
s... N N �
a,,
b
..
4-4 Q
° � �• o s
,11,) Cr\ ON 01
U
:• Wi O O O O A
M '- /--i ... '-H U
a
0 o O O O o 0 o O O O a 4
O O, 00 [� �O M N '-� ad
U
C O
A
eet
CA
a)
M 5
U
t. . ,.; 6 „ o „,^o
. k ,_
iii
. . ci) a)
cn
ii_C if U
o E E e, G''''
et et •C o N
lic,.;
g_ °
w a N
.� A
,.',') f
ES
I I 1
a
11010ELDRRoc FMFNrc otip
Hanson Aggregates
Southwest Region
Technical Services Lab
1000 N.MacArthur Blvd.
Grand Prairie,TX 75050
Tel. 972-260-3646
Fax. 972-260-3655
www.hansonplc.com
MATERIALS EVALUATION
Coarse Aggregates
Source: Hanson @ Bridgeport(Perch-11111)Plant Technical Services
11777
Type: ASTM//57(1"-/f4) Crushed Lime Stone Report: 2015-777
Lab NO: TS-Weekly-15 Date:02-28-15
Date: Received: 02-01-15
ASTM TEST TEST ASTM C-33
METHOD DESCRIPTION RESULTS Specification
C-136 2" Sieve 100 %Passing
C-136 1-1/2"Sieve 100 %Passing 100
C-136 I" Sieve 99 %Passing 95-100
C-136 3/4" Sieve 80 %Passing --------
C-136 1/2" Sieve 45 %Passing 25-60
C-136 3/8" Sieve 34 %Passing -------
C-136 #4 Sieve 9 %Passing 0-10
C-136 #8 Sieve 2 %Passing 0-5
C-136 #16 Sieve 2 %Passing —
C-117 Decant (-#200 Sieve Washed) 1.38 %Passing 1.5%Max,
C-127 Relative Bulk Specific Gravity, SSD 2.663
C-127 Relative Bulk Specific Gravity, Dry 2.632
C-127 Absorption, 1.0 %
C-29 Unit Weight(Dry Rodded), 104.4 Lbs/Cu.Ft.
C-29 Unit Weight(Dry Loose), 94.1 Lbs/Cu.Ft,
C-29 Voids Content(Dry Rodded), 38.3 %
C-131 L.A.Abrasion, 24.1 %Loss 50% Max.
C-1260 Potential Alkali Reactivity of Aggregates, 0.03 %Exp. 0.1 %Max
C-88 Soundness by Sodium
Sulfate(5 cycles), .............. 2.30 %Loss 12% Max.
C-88 Soundness by Magnesium
Sulfate(5 cycles), ............... 3.90 %Loss 18%Max.
C-123 Light Weight Pieces, 0.01 % 0.5%Max.
C-142 Clay Lumps and Friable Particles, 0.01 % 3.0%Max.
C-25 Calcium Carbonate EQV, 96.0
C-25 Acid Insoluble Residue, 4.0 %
D-4791 Flat Particles ..... 4.1 % ,,, .,,
D-4791 Elongated Particles ..... 3.4 % r.
1 Y
Note:-Hanson Product Code TX-126 t,r '
1r:. y;.J.'-t"1 iDk:,0,1::/,'"
Vartan Babakhanian,P.E.
Technical Services Lab Manager
Our letters,analysis and reports are for the exclusive use of the client to whom they are addressed,apply only to the samples tested and'or inspected and are not necessarily
indicative of the qualities of apparently identical or similar products.This report shall not be reproduced except in fill and with the written approval of IIANSON PLC,
U®t
nuts
HEIDEl JERGCEMENTGroup
Hanson Aggregates
Southwest Region
Technical Services Lab
1000 N.MacArthur Blvd.
Grand Prairie,TX 75050
Tel. 972-260-3646
Fax. 972-260-3655
www.hansonplc.com
MATERIALS EVALUATION
Fine& Coarse Aggregates
Source: Hanson @ Bridgeport(Perch-Hill)Plant Technical Services
Manufactured Sand #777
Type: ASTM C-33 Crushed Lime Stone Report: 2015-777
Lab NO: TS-Weekly-15 Date:02-28-15
Date: Received:02-02-15
ASTM TEST TEST ASTM C-33 TX DOT Specs.
METHOD DESCRIPTION RESULTS Specification ITEM 421
%Retained % Passing %Passing %Passing
C-136 3/8" (9.50 mm) Sieve 0 100 100 100
C-136 #4 (4.75 mm) Sieve I 99 95-100 95-100
C-136 #8 (2.36 mm) Sieve 20 80 80-100 80-100
C-136 #16 (1.18 mm) Sieve 48 52 50-85 50-85
C-136 #30 (0.60 mm) Sieve 68 32 25-60 25-65
C-136 #50 (0.30 mm) Sieve 85 15 5-30 10-35
C-136 #100(0.15 mm) Sieve 94 6 0-10 0-10
C-136 Fineness Modulus 3.15 2.3--3.1
C-I 17 Decant (-4200 Sieve Washed) 3.60 %Passing 5.0%Max. 6.0%Max
C-127 Relative Bulk Specific Gravity, SSD 2.626
C-127 Relative Bulk Specific Gravity, Dry 2.596
C-127 Absorption, 1.9 %
C-29 Unit Weight(Dry Rodded), 110.3 Lbs/Cu.Ft.
C-29 Unit Weight(Dry Loose), 100.2 Lbs/Cu.Ft.
C-29 Voids Content(Dry Rodded), 32.7 %
D-2419 Sand Equivalent Value, 85
C-40 Organic Matter(P,F), P Liter Than#3
C-88 Soundness by Sodium
Sulfate(5 cycles), 2.70 %Loss 10.0 % Max,
C-88 Soundness by Magnesium
Sulfate(5 cycles), 3.20 %Loss 15.0 %Max.
C-25 Calcium Carbonate EQV, 96.0 % ei
C-25 Acid Insoluble Residue, 4.0 % ;
C-1260 Potential Alkali Reactivity of Aggregates, 0.03 %Exp. 0.1 %Max
Note: Hanson Product Code TX-389
/e4/.,iii: fi/1 7 ia, .
... .,.. .:,. ....:,..,..,,,-,:,.. , ,
Vartan Babakhanian,P.E.
Technical Services Lab Manager
Product Data Sheet
Edition 09.25.2009
Identification no. 147-540
Sika Air
Sika° Air
Air Entraining Admixture
Description Sika Air admixture is an aqueous solution of organic materials.
Sika Air meets the requirements of ASTM C-260 for air entraining admixtures.
Applications Sika Air is recommended for use whenever air entrained concrete is desired.
Ready-mix, precast and block producers can achieve predictable and uniform
entrained air contents in concrete, even where harsh lean mixes are used or
fly-ash is added to the concrete.
Advantages Durability:
•Air entrainment is recognized as the most effective prevention against con-
crete scaling in exposed environments.Air entrained concrete delivers par-
ticular benefits in the form of increased concrete durability.This is important
in colder climates where frost and freeze-thaw cycles can cause scaling and
damage to the concrete surface.
•Air entraining agents help to prevent scaling by creating microscopic air
voids that water trapped in the concrete can expand into when the concrete
freezes, thus preventing cracks caused by the natural expansion. Entrained
air voids in the concrete will also increase durability in harsh environments
where concrete is exposed to deicing salts, marine salts and sulfates.
Workability and Placeability:
•Workability and placeability are also improved by the lubricating action of the
microscopic bubbles in the concrete. Concrete will flow better, and bleeding
and shrinkage will be reduced because less water is needed to obtain the
desired workability.
How to Use
Dosage Dosage rates for Sika Air will typically fall between 0.5 and 3 fl. oz. per 100
lbs. (32- 195 m1/100 kg) of cementitious to entrain between 4 and 6 percent
air. Higher air contents may be obtained by increasing the dosage rate.
Dosage rates will vary depending on the air content required for a particular
project. Typically air contents will be specified in the range of 4 to 8 percent by
volume.
Other factors that may affect the amount of air entrained into the concrete
including total cementitious content, type of pozzolanic materials, sand grada-
tion, salt/clay in aggregates, temperature and water content.The use of fly
ash, particularly high LOI fly ash, can result in a higher dosage of air entrain-
ment. Sika recommends that trial mixes be performed whenever material or
any other changes are made that may affect the amount of entrained air.
In mixes requiring a lower or higher amount dosage rate, please contact your
local regional Sika office or Sika technical service department at 1-800-933-
7452
y 7 s
for further information.
� r R
Mixing Measure the required quantity per batch manually or with automatic dispenser
equipment.Add Sika Air to mixing water or sand. Do not mix with dry cement.
When Sika Air is used in combination with other admixtures, care must be
taken to dispense each admixture separately into the mix.
Combination with Other Admixtures:
Combination with other admixtures, particularly water reducers and retarders,may
increase the amount of entrained air in the mix.Air contents should be checked with
an air-meter after batching and dosage adjustments made at the concrete plant.
Packaging Sika Air is available in 55 gallon drum (208 liter), 275 gallon totes (1040 liters)
drums and bulk delivery.
Storage and Shelf life Sika Air should be stored at above 40°F (5°C). If frozen, thaw and agitate
thoroughly to return to normal state.
Shelf life when stored in dry warehouse conditions between 50°F and 80°F
(10°C-27°C) is one year.
Typical Data
Appearance Dark Amber liquid.
Specific Gravity Approx. 1.0
CAUTION: IRRITANT Contains Aqueous Solution (CAS:Mixture). May cause eye/skin/respiratory
irritaton. May be harmful if swallowed.
Handling and Storage Avoid direct contact. Wear personal protective equipment(chemical resistant
goggles/gloves/clothing)to prevent direct contact with skin and eyes. Use
only in well ventilated areas. Wash thoroughly with soap and water after use.
Remove contaminated clothing and launder before reuse.
First Aid Eyes: Hold eyelids apart and flush thoroughly with water for 15 minutes. Skin:
Remove contaminated clothing.Wash skin thoroughly for 15 minutes with
soap and water. Inhalation: Remove person to fresh air. Ingestion: Do not
induce vomiting. Dilute with water. Contact physician. In all cases contact a
physician immediately if symptoms persist.
Safety Tested and Certified by WQA according to NSF/ANSI 61 Section 5 for
materials safety.
Clean Up Use personal protective equipment(chemical resistant goggles/gloves/cloth-
ing). Without direct contact, remove spilled or excess product and place in
suitable sealed container. Dispose of excess product and container in accor-
dance with applicable environmental regulations.
KEEP CONTAINER TIGHTLY CLOSED•KEEP OUT OF REACH OF CHILDREN•NOT FOR INTERNAL CONSUMPTION•FOR INDUSTRIAL USE ONLY
All information provided by Sika Corporation("Sika")concerning Sika products,including but not limited to,any recommendations and advice
relating to the application and use of Sika products,is given in good faith based on Sika's current experience and knowledge of its products
when properly stored,handled and applied under normal conditions in accordance with Sika's instructions.In practice,the differences in materi-
als,substrates,storage and handling conditions,actual site conditions and other factors outside of Sika's control are such that Sika assumes no
liability for the provision of such information,advice,recommendations or instructions related to its products,nor shall any legal relationship be
created by or arise from the provision of such information,advice,recommendations or instructions related to its products.The user of the Sika
product(s)must test the product(s)for suitability for the intended application and purpose before proceeding with the full application of the product(s).
Sika reserves the right to change the properties of its products without notice. All sales of Sika product(s)
are subject to its current terms and conditions of sale which are available at www.sikacorp.com or by calling 800-933-7452.
Prior to each use of any Sika product,the user must always read and follow the warnings and instructions on the product's most cur-
rent Technical Data Sheet, product label and Material Safety Data Sheet which are available at www.sikaconstruction.com or
800-933-7452.Nothing contained in any Sika materials relieves the user of the obligation to read and follow the warnings and instruction
for each Sika product as set forth in the current Technical Data Sheet,product label and Material Safety Data Sheet prior to product use.
SIKA warrants this product for one year from date of installation to be free from manufacturing defects and to meet the technical properties
on the current Technical Data Sheet if used as directed within shelf life. User determines suitability of product for intended use and
assumes all risks.Buyer's sole remedy shall be limited to the purchase price or replacement of product exclusive of labor or cost of labor.
NO OTHER WARRANTIES EXPRESS OR IMPLIED SHALL APPLY INCLUDING ANY WARRANTY OF MERCHANTIBILITY
OR FITNESS FOR A PARTICULAR PURPOSE. SIKA SHALL NOT BE LIABLE UNDER ANY LEGAL THEORY FOR
SPECIAL OR CONSEQUENTIAL DAMAGES. SIKA SHALL NOT BE RESPONSIBLE FOR THE USE OF THIS PRODUCT IN
A MANNER TO INFRINGE ON ANY PATENT OR ANY OTHER INTELLECTUAL PROPERTY RIGHTS HELD BY OTHERS.
Sika Corporation Sika Canada Inc.
201 Polito Avenue 601,Delmar Avenue "0`ESie
r,
^, Lyndhurst,NJ 07071 Pointe-Claire,QC H9R 4A9 1-800-933-SIKA
Phone: (201)933-8800 Phone: (514)697-2610 �it
0°
Fax: (201)933-6225 Fax: (514)697-3087 rvw,rvF c.•farwe�.r
wwwsikaconstruction.com wwwsika.ca
Regional Information and Sales Centers.For the location of your nearest Sika representative,contact your regional center.
ki. U.S.: North East Region: Fairless Hills,PA,Phone:(215)295-6600 North Central Region: Marion,OH,Phone:(800)851-1545
J South East Region: Conyers,GA,Phone:(770)760-1300 South Central Region: Mesquite,TX,Phone:(972)289-6480
r�TG f � Western Region: Santa Fe Springs,CA,Phone:(562)903-3650
Canada: Ontario: Mississauga,ON,Phone:(905)795-3177, Alberta: Edmonton,AB,Phone:(780)486-6111
Quality Certification Numbers:Lyndhurst:FM 69711(ISO 9000),FM 70421(QS 9000),Marion:FM 69715,Kansas City:FM 69107,Santa Fe Springs:FM 69408
Sika is a registered trademark.Made in USA.Printed in USA.
Product Data Sheet
Edition 12.2005 ���
Identification no. 180-540 SikascoCrete®
Sikament 686 Technology
Sikament® 686
High Range and Mid Range Water Reducing Admixture
Description Sikament 686 is a high range water reducing admixture utilizing Sika's Visco-
Crete Technology. It's unique formulation is based on polycarboxylate
technology.
Sikament 686 meets the requirements for ASTM C-494 Types A and F.
Applications Sikament 686 is recommended for use in the production of all high strength
concrete products, whenever high plasticity and increased early and ultimate
strengths are desired.
The superplasticizing action of Sikament 686 provides excellent workability at
low water cement ratios.
Advantages High Range Water Reducing Applications: When used as a high range wa-
ter reducing admixture,water reduction up to 30% can be obtained. The su-
perplasticizing action allows for the production of high slump flowing concrete
with excellent workability that can be placed with minimum vibration even at
a low water/cement ratio. The dispersing action of Sikament 686 maximizes
cement hydration efficiency and improves concrete's early and long term com-
pressive strengths.
Mid Range Water Reducing Applications:At a lower dosage, Sikament 686
can be used as a cost effective mid range water reducing admixture or simply
as a water reducing admixture for production of conventional slump concrete.
When used as a mid range water reducing admixture,water reduction up to
15% can be obtained. This application is ideal for use with lean, harsh con-
crete mixes or concrete containing flyash. Sikament 686 will improve
workability and finishability.
The combined water reducing and superplasticizing action provide the follow-
ing benefits:
• Higher early and ultimate strengths for cost effective high strength con-
crete and earlier structural use of concrete.
• Higher early strengths allow faster demolding and more efficient use of
forms to precast producers.
• Increased slump improves workability and reduces labor costs.
• Full flow action aids in pumping and reduces need for vibration.
• Greater concrete density reduces permeability and increases durability.
Sikament 686 does not contain calcium chloride or any other intentionally
added chlorides and will not initiate or contribute to corrosion on steel rein-
forcement present in the concrete.
How to Use -
Dosage Dosage rates will vary depending on the material used, ambient conditions
and the requirements of a specific project.
For general concreting applications, Sika recommends a dosage rate between
3-12 fl. oz. /100 lbs. (195-780 m1/100 kg) cementitious materials. If maximum
water reduction is required, dosage up to 18 fl.oz./100 lbs. (1170 m1/100 kg) of
cementitious materials may be used. In this case, delayed setting times may
occur. Dosage rates outside the recommended range may be used where
specialized materials such as microsilica are specified, extreme ambient
conditions are encountered or unusual project conditions require special con-
JO e
our local re SffiSika
p Y g
technical sideration.service In this departmentcase at 1-800-933-7452 for further ional informaikaocetion.or
�r ® Mixing For best plasticizing results, Sikament 686 should be added directly
to freshly mixed concrete in the concrete mixer at the end of the batching
..aQ cycle.
Sikament 686 may also be dispensed as an integral material during the regu-
lar admixture batching cycle, or into freshly mixed concrete in a Ready-Mix
truck at the concrete plant or job site.
To optimize the superplasticizing effect, Sika recommends that the combined
materials be mixed for 80-100 revolutions, either in the concrete mixer or in
the Ready-Mix truck.
Combination with other Admixtures: Sikament 686 is highly effective as a
single admixture or in combination with other admixtures in the Sika System.
If used in combination with certain Sikament high range water reducers, it
may affect the plastic properties of fresh concrete. Please contact your local
regional office or technical service department at 1-800-933-7452 for further
information.
Combination with Microsilica: Sikament 686 is particularly well suited for
use with Microsilica because of its water reduction capability.
Packaging Sikament 686 is available in 55 gallon drum (208 liter), 275 gallon totes
(1040 liters)and bulk delivery.
Storage and Shelf Life Sikament 686 should be stored at above 40°F (5°C). If frozen,thaw and agi-
tate thoroughly to return to normal state. Protect from direct sunlight.
Shelf life when stored in dry warehouse conditions between 40°F and 80°F
(5°C-27°C) is one year.
Typical Data --- --- - -- -
Appearance Brown liquid.
Specific Gravity Approx. 1.1
CAUTiON: iRRiTANT Contains Aqueous Polymer Solution (CAS:Mixture), Triethanolamine (CAS:
102-71-6). May cause eye/skin/respiratory irritation. May be harmful if swallowed.
Handling and Storage Avoid direct contact. Wear personal protective equipment(chemical resistant
goggles/gloves/clothing)to prevent direct contact with skin and eyes. Use
only in well ventilated areas. Wash thoroughly with soap and water after use.
Remove contaminated clothing and launder before reuse.
First Aid Eyes: Hold eyelids apart and flush thoroughly with water for 15 minutes. Skin:
Remove contaminated clothing. Wash skin thoroughly for 15 minutes with
soap and water. inhalation: Remove to fresh air. ingestion: Do not induce
vomiting. Dilute with water. Contact physician. in all cases contact a physi-
cian immediately if symptoms persist.
Clean Up Use personal protective equipment (chemical resistant goggles/gloves/cloth-
ing).Without direct contact, remove spilled or excess product and place in
suitable sealed container. Dispose of excess product and container in accor-
dance with applicable environmental regulations.
KEEP CONTAINER TIGHTLY CLOSED•KEEP OUT OF REACH OF CHILDREN•NOT FOR INTERNAL CONSUMPTION•FOR INDUSTRIAL USE ONLY
All information provided by Sika Corporation("Sika")concerning Sika products,including but not limited to,any recommendations and advice
relating to the application and use of Sika products,is given in good faith based on Sika's current experience and knowledge of its products
when properly stored,handled and applied under normal conditions in accordance with Sika's instructions.In practice,the differences in materi-
als,substrates,storage and handling conditions,actual site conditions and other factors outside of Sika's control are such that Sika assumes no
liability for the provision of such information,advice,recommendations or instructions related to its products,nor shall any legal relationship be
created by or arise from the provision of such information,advice,recommendations or instructions related to its products.The user of the Sika
product(s)must test the product(s)for suitability for the intended application and purpose before proceeding with the full application of the product(s).
Sika reserves the right to change the properties of its products without notice. All sales of Sika product(s)
are subject to its current terms and conditions of sale which are available at www.sikacorp.com or by calling 800-933-7452.
Prior to each use of any Sika product,the user must always read and follow the warnings and instructions on the product's most cur-
rent Technical Data Sheet, product label and Material Safety Data Sheet which are available at www sikaconstruction corn or
800-933-7452. Nothing contained in any Sika materials relieves the user of the obligation to read and follow the warnings and instruction
for each Sika product as set forth in the current Technical Data Sheet,product label and Material Safety Data Sheet prior to product use.
SIKA warrants this product for one year from date of installation to be free from manufacturing defects and to meet the technical properties
on the current Technical Data Sheet if used as directed within shelf life. User determines suitability of product for intended use and
assumes all risks.Buyer's sole remedy shall be limited to the purchase price or replacement of product exclusive of labor or cost of labor
NO OTHER WARRANTIES EXPRESS OR IMPLIED SHALL APPLY INCLUDING ANY WARRANTY OF MERCHANTIBILITY
OR FITNESS FOR A PARTICULAR PURPOSE. SIKA SHALL NOT BE LIABLE UNDER ANY LEGAL THEORY FOR
SPECIAL OR CONSEQUENTIAL DAMAGES. SIKA SHALL NOT BE RESPONSIBLE FOR THE USE OF THIS PRODUCT IN
A MANNER TO INFRINGE ON ANY PATENT OR ANY OTHER INTELLECTUAL PROPERTY RIGHTS HELD BY OTHERS.
Sika Corporation Sika Canada Inc. BSI
201 Polito Avenue 601,Delmar Avenue
Lyndhurst,NJ 07071 Pointe-Claire,QC H9R 4A9 1-800-933-SIKA
Phone: (201)933-8800 Phone: (514)697-2610
Fax: (201)933-6225 Fax: (514)697-3087
R wwwsikaconstruction.com wwwsika.ca ISO 9090:2000
a ® Regional Information and Sales Centers.For the location of your nearest Sika representative,contact your regional center.
�'' U.S.: North East Region: Fairless Hills,PA,Phone:(215)295-6600 North Central Region: Marion,OH,Phone:(800)851-1545
r °a South East Region: Conyers,GA,Phone:(770)760-1300 South Central Region: Mesquite,TX,Phone:(972)289-6480
Western Region: Santa Fe Springs,CA,Phone:(562)903-3650
Canada: Ontario: Mississauga,ON,Phone:(905)795-3177, Alberta: Edmonton,AB,Phone:(780)486-6111
Quality Certification Numbers:Lyndhurst:FM 69711(ISO 9000),FM 70421(QS 9000),Marion:FM 69715,Kansas City:FM 69107,Santa Fe Springs:FM 69406
Sika and Sikament am registered trademarks.Made in USA.Printed in USA.
Product Data Sheet
Edition 10.2005
Identification no. 100-54
Plastiment
Plastiment®
Water Reducing and Retarding Admixture
Description Plastiment is a water-reducing and retarding admixture.
Plastiment meets the requirements of ASTM C-494 Types B and D.
Applications Plastiment is recommended for use whenever high quality concrete with pre-
dictable and controlled set times is desired. Use in flatwork and horizontal or
vertical slipform placements where a superior surface finish is required.
Advantages Plastiment is highly effective in hot weather concreting to offset the accelerat-
ing effects of high ambient temperatures by slowing the hydration reaction and
controlling the hydration heat. Concrete workability is enhanced and a supe-
rior surface finish is obtained.
In mass concrete pours Plastiment controls temperature rise and reduces the
risk of thermal cracking.
• Initial set times are delayed, allowing time for proper placement and fin-
ishing without cold joints in hot weather conditions.
• Plastiment increases concrete density and delivers increased early and
ultimate, compressive and flexural strengths.
• For flatwork applications Plastiment acts as a finishing aid, workability is
improved, bleeding is controlled and a superior surface finish is obtained.
• Lower water cement ratios provide decreased permeability and increased
durability.
• Plastiment can be used to retard concrete during the hot weather con-
creting. Refer to ACI 305R Hot Weather Concreting for more information.
Plastiment does not contain calcium chloride or any other intentionally added
chlorides.
How to Use
Dosage Dosage rates will vary depending on the material used, ambient conditions
and the requirements of a specific project.
For general concreting applications, Sika recommends a dosage rate
between 2-4 fl. oz./100 lbs. (130-260 m1/100 kg) of cementitious materials.
Where extended retardation is required dosage may be increased. Dosage
rates outside the recommended range may be used where specialized materi-
als such as microsilica are specified, extreme ambient conditions are encoun-
tered or unusual project conditions require special consideration. In this case
please contact your local regional Sika office or Sika technical service
department at 1-800-933-7452 for further information.
Mixing Add Plastiment at the concrete plant. Measure required quantity manually or
by automated dispenser.Add into the water line at the batch plant or directly
into the concrete at the end of the mixing cycle.
Combination with other Admixtures: Plastiment works effectively as a
single admixture or in combination with other admixtures in the Sika System.
When used in combination with other admixtures, care must be taken to dis-
pense each admixture separately into the mix. Do not mix with dry cement.
Packaging Plastiment is supplied in 55 gallon (208 liter) drums and bulk delivery.
Storage and Shelf-life Plastiment should be stored at above 40°F (5°C). If frozen, thaw and agitate
thoroughly to return to normal state before use.
Shelf life when stored in dry warehouse conditions between 50°F and 80°F
(10°C-27°C) is one year.
Typical Data
Appearance Flourescent Green Brown liquid.
Specific Gravity Approx. 1.2
Caution Skin and eye irritant; avoid contact. The use of NIOSH approved respirator,
safety goggles and rubber gloves is recommended.Avoid breathing product.
Use with adequate ventilation. Remove contaminated clothing.
Handling and Storage Avoid direct contact. Wear personal protective equipment(chemical resistant
goggles/gloves/clothing)to prevent direct contact with skin and eyes. Use
only in well ventilated areas.Wash thoroughly with soap and water after use.
Remove contaminated clothing and launder before reuse.
First Aid Eyes: Hold eyelids apart and flush thoroughly with water for 15 minutes. Skin:
Remove contaminated clothing.Wash skin thoroughly for 15 minutes with
soap and water. Inhalation: Remove person to fresh air. Ingestion: Do not
induce vomiting. Dilute with water. Contact a physician. In all cases, contact
a physician immediately if symptoms persist.
Clean Up Use personal protective equipment(chemical resistant goggles/gloves/cloth-
ing).Without direct contact, remove spilled or excess product and place in
suitable sealed container. Dispose of excess product and container in accor-
dance with applicable environmental regulations.
KEEP CONTAINER TIGHTLY CLOSED KEEP OUT OF REACH OF CHILDREN
NOT FOR INTERNAL CONSUMPTION FOR INDUSTRIAL USE ONLY
CONSULT MATERIAL SAFETY DATA SHEET FOR MORE INFORMATION
Sika warrants this product for one year from date of installation to be free from manufacturing defects and to meet the technical properties on the
current Technical Data Sheet if used as directed within shelf life.User determines suitability of product for intended use and assumes all risks.
Buyer's sole remedy shall be limited to the purchase price or replacement of product exclusive of labor or cost of labor.
NO OTHER WARRANTIES EXPRESSED OR IMPLIED SHALL APPLY INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR
A PARTICULAR PURPOSE.SIKA SHALL NOT BE LIABLE UNDER ANY LEGAL THEORY FOR SPECIAL OR CONSEQUENTIAL DAMAGES.
SIKA SHALL NOT BE RESPONSIBLE FOR THE USE OF THIS PRODUCT IN A MANNER TO INFRINGE ON ANY PATENT OR ANY OTHER
INTELLECTUAL PROPERTY RIGHTS HELD BY OTHERS.
Sika Corporation Sika Canada Inc. 1-800-933-SIKA QUALITY
201 Polito Avenue 601,Delmar Avenue
Lyndhurst,NJ 07071 Pointe-Claire,QC H9R 4A9 ISO 9001
Phone: (201)933-8800 Phone:(514)697-2610 9002
Fax:Fax: (201)933-6225 Fax: (514)697-3087 q
�,ker www.sikaconstruction.com www.sika.ca CHIEvEMEN
Regional Information and Sales Centers.For the location of your nearest Sika representative,contact your regional center.
U.S.: North East Re Ion: Fairless Hills,PA,Phone: 215)295-6600 North Central Re Ion: Marion,OH,Phone: 800 851-1545
South East Region: Conyers,GA,Phone:(770)760-1300 South Central Region: Mesquite,TX,Phone:(9728)5218-
)289-6480
� �: Westem Region: Santa Fe Springs,CA,Phone:(562)903-3650
Canada: Ontario: Mississauga,ON,Phone (905)795-3177, Alberta: Edmonton,AB,Phone:(780)486-6111
Quality Certification Numbers:Lyndhurst:FM 69711(ISO 90001,FM 70421(QS 90001,Marion:FM 69715,Kansas City:FM 69107,Santa Fe Springs:FM 69406
Sika and Plastiment are registered trademarks.
Made in USA.Printed in USA.
December 4,2014
Cowtown Redi Mix
PO Box 162327
Ft,Worth,TX 76161
STATE OF TEXAS
COUNTY OF DALLAS
This is to certify that Sika Air,is manufactured under strict quality control conditions by Sika Corpora-
tion,315 N.Ebrite Street,Mesquite,TX 75149,and that it meets the requirements of ASTM C-260 for air
entraining admixtures and AASHTO M-154.
We further certify that there are no chlorides added during the manufacturing of Sika Air.As well, the Sika
Air supplied is identical in all respects,including concentration to the admixture previously submitted for
approval to the Texas Department of Transportation
e he't'ra. ey
Regiona . .ger
Sworn and subscribed to before me this day of December 4,2014.
;t ,
"IF,p m.,, AUTUMN REEVES Aut 'eeves
t '` NotaryPublic.State of Texas
,,v,1 i my ommission Expires Notary Public
" 4r "� November 14,2016
',,,,,w,
.. ,. _ ._.
,,l's
CI
® Sika Corporation,315 North Ebrite Street,Mesquite TX 75149,USA
Tel:972 289 6480,Fax 972 289 5721,www.sikausa.com
December 4,2014
Cowtown Redi Mix
PO Box 162327
Ft,Worth,TX 76161
STATE OF TEXAS
COUNTY OF DALLAS
This is to certify that Sikament 686 is manufactured under strict quality control conditions by Sika Corpo-
ration,315 N Ebrite Street,Mesquite,TX 75149,and that it meets the requirements of ASTM C-494,
Types A and F and AASHTO M-194,Types A and F.
We further certify that there are no chlorides added during the manufacturing of Sikament 686. As well,
the Sikament 686 supplied is identical in alI respects,including concentration to the admixture previously
submitted for approval to the Texas Department of Transportation.
Stephe .Brad ey
Regional Manager
Sworn and subscribed to before me this day of 4 December 2014.
Autumn Reeves
Notary Public
AUTUMN REEVES
�,: _Notary Pudic,State of Texas
;:40, My Commission Expires
NOvetnber 14,2015
ihaIQ Sika Corporation,315 North Ebrite Street,Mesquite TX 75149,USA
Tel 972 289 6480,Fax:972 289 5721,www sikausa corn
December 4,2014
Cowtown Redi Mix
PO Box 162327
Ft.Worth,TX 76161
STATE OF TEXAS
COUNTY OF DALLAS
This is certify that Plastiment,is manufactured under strict quality control conditions by Sika Corporation,
315 N.Ebrite Street,Mesquite,TX 75149,and that it meets the requirements of ASTM C-494,Types B
and D and AASHTO M-194 Types B and D.
We further certify that there are no chlorides added during the manufacturing of Plastiment, As well,the
Plastiment supplied is identical in all respects, including concentration to the admixture previously sub-
mitted for approval to the Texas Department of Transportation.There is no chloride used in the manufac-
turing of Plastiment.
'410111
Step_':I adley
Regional Manager
Sworn and subscribed before me this day oo •er 4,2014.
1A'/
/'
A tumn Reeves
Nota Public
41.
1::�� �YComr�issionExpiresas
Ncsvember 14,2015
alha
® Sika Corporation,315 North Ebrite Street Mesquite TX 75149,USA
II
Tel:972 289 6480,Fax:972 289 5721,wwwsikausa.com