Loading...
Tax 2016B-LR171122 Company: Kimley Horn City, State: Coppell, TX Job: Airline Dr. Description: Pre TV Sanitary Sewer Date: 11/22/2017 Contact: Inspector: bxr e Mt, DAllAS, TEXAS •/ 44W 4116 Aav tek ion SErVic. 65' ACME Utility Inspection Services, Inc. 2105 Waterview Pkwy. Richardson, TX 75080 Office: (972) 247-7741 Fax: (972) 247-7074 Email: acmeinspection@yahoo.corn www.acmetelcompany.corn pole Utility ACME Utility Inspection Services, Inc. 2105 Waterview Pkwy., Richardson, TX 75080 '' Tel.972-247-7741 �e�t!nn ErvIC' acmeinspection@yahoo.com Inspection report Date: Work Order: Surveyed By: Certificate Number: Pipe Segment Ref. : Section Number. : 11/20/2017 Default Jesus Alvarado U-206-2298 555 Building Souh Line-1-1 1 Weather: Pre-cleaning : Direction: Pipe Joint Length: Total Length: Length Surveyed: Dry No Pre-Cleaning Upstream 14.0 60.0 60.0 City: Copell Drainage Area : Upstream MH: 555 Building Souh Line-1 Street: Airline,Dr Media Label : Up Rim to Invert: 0.0 Location Code: Main highway-suburban/rural Flow Control: Not Controlled Downstream MH : 1 Location Details : Sheet Number: Down Rim to Invert: 0.0 Pipe shape: Circular Sewer Use: Sanitary Pipe size: 8 Pipe material: Polyvinyl Chloride Purpose: Pre-Rehabilitation Survey Lining Method: Owner: Additional Info: Souht Line-1 1:525 Distance Code Observation Grade 1 0.00 AMH Manhole/1 Line-East 0 I0.00 MWL Water Level, 5%of cross sectional area 5.00 MGO General Observation/Survey Begins Itr le 60.00 AEP End of Pipe/Reached Stopping Point Building 555 555 Buil.ing Souh Line-1 QSR I QMR I SPR I MPR I OPR I SPRI I MPRI I OPRI 0000 0000 0.0 0.0 0.0 0.0 0.0 0.0 Copell Airline,Dr//Page: 1 Pone UtilityACME Utility Inspection Services, Inc. �; 2105 Waterview Pkwy., Richardson, TX 75080 ''so o'. Tel. 972-247-7741 Rcri°"sE'rv"4g acmeinspection@yahoo.com Inspection report Date: Work Order: Surveyed By: Certificate Number: Pipe Segment Ref. : Section Number. : 11/20/2017 Default Jesus Alvarado U-206-2298 1-2 2 Weather: Pre-cleaning: Direction : Pipe Joint Length : Total Length : Length Surveyed: Dry Jetting Downstream 14.0 382.0 382.0 City: Copell Drainage Area: Upstream MH : 1 Street: Airline,Dr Media Label : Up Rim to Invert: 0.0 Location Code: Main highway-suburban/rural Flow Control: Not Controlled Downstream MH : 2 Location Details: Sheet Number: Down Rim to Invert: 0.0 — Pipe shape: Circular Sewer Use: Sanitary Pipe size: 10 Pipe material: Polyvinyl Chloride Purpose: Pre-Rehabilitation Survey Lining Method : Owner: Additional Info: Line-East 1:3337 Distance Code Observation Grade 1 0.00 AMH Manhole/1 Line-East 0.00 MWL Water Level, 5%of cross sectional area 5.00 MGO General Observation/Survey Begins 44, e382.00 AMH Manhole/2 Line-East 2 QSR I QMR I SPR I MPR I OPR I SPRI I MPRI I OPRI 0000 0000 0.0 0.0 0.0 0.0 0.0 0.0 Copell Airline,Dr//Page:2 Q,cmE Utility ACME Utility Inspection Services, Inc. 2105 Waterview Pkwy., Richardson, TX 75080 *s, —11,- �`'. Tel. 972-247-7741 `""sLrv%" acmeinspection@yahoo.com Inspection report Date: Work Order: Surveyed By: Certificate Number: Pipe Segment Ref. : Section Number. : 11/20/2017 Default Jesus Alvarado U-206-2298 Souht Line-2-2 3 Weather: Pre-cleaning : Direction : Pipe Joint Length: Total Length: Length Surveyed : Dry No Pre-Cleaning Upstream 14.0 50.0 50.0 City: Copell Drainage Area: Upstream MH : Souht Line-2 Street: Airline,Dr Media Label : Up Rim to Invert: 0.0 Location Code: Main highway-suburban/rural Flow Control: Not Controlled Downstream MH: 2 Location Details: Sheet Number: Down Rim to Invert: 0.0 — Pipe shape: Circular Sewer Use: Sanitary Pipe size: 10 Pipe material: Polyvinyl Chloride Purpose: Pre-Rehabilitation Survey Lining Method: Owner: Additional Info: Souht Line-2 1:437 Distance Code Observation Grade 2 elf 0.00 AMH Manhole/2 Line-East ' 0.00 MWL Water Level, 5%of cross sectional area 5.00 MGO General Observation/Survey Begins T'^ 50.00 AEP End of Pipe/Reached Stopping Point Souht Line-2 Souht Line-2 QSR I QMR I SPR I MPR I OPR I SPRI I MPRI I OPRI 0000 0000 0.0 0.0 0.0 0.0 0.0 0.0 Copell Airline,Dr//Page:3 Pane utilityACME Utility Inspection Services, Inc. �— 2105 Waterview Pkwy.,Richardson, TX 75080 ''s% oc.' Tel. 972-247-7741 €c'"°"s ra"5 acmeinspection@yahoo.com Inspection report Date: Work Order: Surveyed By: Certificate Number: Pipe Segment Ref. : Section Number. : 11/20/2017 Default Jesus Alvarado U-206-2298 2-3 4 Weather: Pre-cleaning : Direction: Pipe Joint Length: Total Length: Length Surveyed Dry Jetting Downstream 14.0 220.2 220.2 City: Copell Drainage Area: Upstream MH: 2 Street: Airline,Dr Media Label : Up Rim to Invert: 0.0 Location Code: Main highway-suburban/rural Flow Control: Not Controlled Downstream MH : 3 Location Details: Sheet Number: Down Rim to Invert: 0.0 Pipe shape: Circular Sewer Use: Sanitary Pipe size: 10 Pipe material: Polyvinyl Chloride Purpose: Pre-Rehabilitation Survey Lining Method : Owner: Additional Info: Line-East 1:1924 Distance Code Observation Grade 2 e0.00 AMH Manhole/2 Line-East 0.00 MWL Water Level, 10%of cross sectional area 5.00 MGO General Observation/Survey Begins 0 220.20 AMH Manhole/3 Line-East 3 QSR QMR SPR MPR OPR SPRI MPRI OPRI _ 0000 0000 0.0 0.0 0.0 0.0 0.0 0.0 Copell Airline,Dr II Page:4 pole UtilityACME Utility Inspection Services, Inc. '''''''14?" 2105 Waterview Pkwy.,Richardson, TX 75080 �,S Tel. 972-247-7741 "Uon Service`'. acmeinspection@yahoo.com Inspection report Date: Work Order: Surveyed By: Certificate Number: Pipe Segment Ref. : Section Number. : 11/20/2017 Default Jesus Alvarado U-206-2298 3-4 5 Weather: Pre-cleaning : Direction: Pipe Joint Length: Total Length: Length Surveyed Dry No Pre-Cleaning Downstream 14.0 272.0 272.0 City: Copell Drainage Area: Upstream MH : 3 Street: Airline,Dr Media Label: Up Rim to Invert: 0.0 Location Code: Main highway-suburban/rural Flow Control: Not Controlled Downstream MH: 4 Location Details : Sheet Number: Down Rim to Invert: 0.0 Pipe shape: Circular Sewer Use: Sanitary Pipe size: 10 Pipe material: Polyvinyl Chloride Purpose: Pre-Rehabilitation Survey Lining Method : Owner: Additional Info: Line-East 1:2376 Distance Code Observation Grade 3 ell 0.00 AMH Manhole/4 Line-East 0.00 MWL Water Level, 10%of cross sectional area r 0 272.00 AMH Manhole/4 Line-East 4 QSR I QMR I SPR I MPR I OPR I SPRI I MPRI I OPRI 0000 0000 0.0 0.0 0.0 0.0 0.0 0.0 Copell Airline,Dr//Page: 5 P�me Utility ACME Utility Inspection Services, Inc. �"� 2105 Waterview Pkwy., Richardson, TX 75080 s vst- Tel. 972-247-7741 "eCtiOn L r,ic . acmeinspection@yahoo.com Inspection report Date: Work Order: Surveyed By: Certificate Number: Pipe Segment Ref. : Section Number. : 11/20/2017 Default Jesus Alvarado U-206-2298 Souht Line-3-3 6 Weather: Pre-cleaning: Direction : Pipe Joint Length: Total Length: Length Surveyed: Dry Jetting Upstream 14.0 50.0 50.0 City: Copell Drainage Area: Upstream MH : Souht Line-3 Street: Airline,Dr Media Label : Up Rim to Invert: 0.0 Location Code: Main highway-suburban/rural Flow Control: Not Controlled Downstream MH : 3 Location Details: Sheet Number: Down Rim to Invert: 0.0 Pipe shape: Circular Sewer Use: Sanitary Pipe size: 10 Pipe material: Polyvinyl Chloride Purpose: Pre-Rehabilitation Survey Lining Method: Owner: Additional Info: Souht Line-3 1:437 Distance Code Observation Grade 3 0.00 AMH Manhole/3 Line-East 4111 IN 0.00 MWL Water Level, 10%of cross sectional area 5.00 MGO General Observation/Survey Begins i 0 50.00 AEP End of Pipe/Reached Stopping Poin Line-3 Souht Line-3 QSR I QMR 1 SPR I MPR I OPR 1 SPRI I MPRI I OPRI 0000 0000 0.0 0.0 0.0 0.0 0.0 0.0 Copell Airline,Dr//Page:6 Pane utility ACME Utility Inspection Services, Inc. �: 2105 Waterview Pkwy.,Richardson, TX 75080 N' Tel. 972-247-7741 ��rro"„,.., 5 acmeinspection@yahoo.corn Inspection report Date: Work Order: Surveyed By: Certificate Number: Pipe Segment Ref. : Section Number. : 11/20/2017 Default Jesus Alvarado U-206-2298 4-5 7 Weather: Pre-cleaning: Direction: Pipe Joint Length : Total Length: Length Surveyed: Dry Jetting Downstream 14.0 509.0 509.0 City: Copell Drainage Area : Upstream MH : 4 Street: Airline,Dr Media Label: Up Rim to Invert: 0.0 Location Code: Main highway-suburban/rural Flow Control: Not Controlled Downstream MH: 5 Location Details: Sheet Number: Down Rim to Invert: 0.0 — Pipe shape: Circular Sewer Use: Sanitary Pipe size: 10 Pipe material: Polyvinyl Chloride Purpose: Pre-Rehabilitation Survey Lining Method: Owner: Additional Info: Line-East 1:4446 Distance Code Observation Grade 4 0.00 AMH Manhole/4 Line-East \ 0.00 MWL Water Level, 10%of cross sectional area 441, e4 5.00 MGO General Observation/Survey Begins 0 509.00 AMH Manhole/5 Line-East 5 QSR QMR I SPR I MPR I OPR I SPRI I MPRI I OPRI 0000 0000 0.0 0.0 0.0 0.0 0.0 0.0 Copell Airline,Dr II Page: 7 oxsne Utility ACME Utility Inspection Services, Inc. �,' 2105 Waterview Pkwy.,Richardson, TX 75080 �' Tel. 972-247-7741 7ri,on ServicES' acmeinspection Q@yahoo.corn Inspection report Date: Work Order: Surveyed By: Certificate Number: Pipe Segment Ref. : Section Number. : 11/20/2017 Default Jesus Alvarado U-206-2298 5-6 8 Weather: Pre-cleaning : Direction: Pipe Joint Length: Total Length : Length Surveyed: Dry Jetting Downstream 14.0 58.0 58.0 City: Copell Drainage Area : Upstream MH: 5 Street: Airline,Dr Media Label: Up Rim to Invert: 0.0 Location Code: Main highway-suburban/rural Flow Control : Not Controlled Downstream MH : 6 Location Details : Sheet Number: Down Rim to Invert: 0.0 Pipe shape: Circular Sewer Use: Sanitary Pipe size: 10 Pipe material: Polyvinyl Chloride Purpose: Pre-Rehabilitation Survey Lining Method: Owner: Additional Info: Line-East 1:507 Distance Code Observation Grade 5 0.00 AMH Manhole/5 Line-East ell ' 0.00 MWL Water Level,45%of cross sectional area 5.00 MGO General Observation/Survey Begins C58.00 AMH Manhole/6 Line-East 6 QSR I QMR ) SPR I MPR I OPR I SPRI I MPRI I OPRI 0000 0000 I 0.0 0.0 0.0 0.0 0.0 0.0 Copell Airline,Dr//Page: 8 pole u 1'!y ACME Utility Inspection Services, Inc. '�"' 2105 Waterview Pkwy., Richardson, TX 75080 ' Tel. 972-247-7741 orb°s`rvKe§ acmeinspection@yahoo.com Inspection report Date: Work Order: Surveyed By: Certificate Number: Pipe Segment Ref. : Section Number. : 11/20/2017 Default Jesus Alvarado U-206-2298 6-7 9 Weather: Pre-cleaning : Direction: Pipe Joint Length: Total Length: Length Surveyed: Dry Jetting Downstream 14.0 591.4 591.4 City: Copell Drainage Area: Upstream MH : 6 Street: Airline,Dr Media Label : Up Rim to Invert: 0.0 Location Code: Main highway-suburban/rural Flow Control : Not Controlled Downstream MH : 7 Location Details: Sheet Number: Down Rim to Invert: 0.0 Pipe shape: Circular Sewer Use: Sanitary Pipe size: 10 Pipe material: Polyvinyl Chloride Purpose: Pre-Rehabilitation Survey Lining Method : Owner: Additional Info: Line-East 1:5166 Distance Code Observation Grade 6 eV0.00 AMH Manhole/6 Line-East 0.00 MWL Water Level, 50%of cross sectional area 0 591.40 MSA Survey Abandoned/Ran Out Of Cable On Whed 7 QSR I QMR I SPR I MPR I OPR I SPRI 1 MPRI I OPRI 0000 0000 0.0 0.0 0.0 0.0 0.0 0.0 Copell Airline,Dr//Page:9 Pcrne utility ACME Utility Inspection Services, Inc. 2105 Waterview Pkwy.,Richardson, TX 75080 ''r off'' Tel. 972-247-7741 °��a°"s`°�r`E,. acmeinspection@yahoo.comm Inspection report Date: Work Order: Surveyed By: Certificate Number: Pipe Segment Ref. : Section Number. : 11/20/2017 Default Jesus Alvarado U-206-2298 6-7 10 Weather: Pre-cleaning : Direction : Pipe Joint Length: Total Length : Length Surveyed: Dry No Pre-Cleaning Upstream 14.0 99.0 99.0 City: Copell Drainage Area: Upstream MH: 6 Street: Airline,Dr Media Label: Up Rim to Invert: 0.0 Location Code: Main highway-suburban/rural Flow Control: Not Controlled Downstream MH : 7 Location Details: Sheet Number: Down Rim to Invert: 0.0 Pipe shape: Circular Sewer Use: Sanitary Pipe size: 10 Pipe material: Polyvinyl Chloride Purpose: Pre-Rehabilitation Survey Lining Method: Owner: Additional Info: Reverse Set Up TV.To Were Cable Ran Out 1:865 Distance Code Observation Grade 7 e0.00 AMH Manhole/7 Line-East 0.00 MWL Water Level, 30%of cross sectional area 5.00 MGO General Observation/Survey Begins S 99.00 MSA Survey Abandoned/TV,To Were Cable Ran Out 6 QSR I QMR SPR I MPR I OPR f SPRI I MPRI I OPRI 0000 0000 0.0 0.0 0.0 0.0 0.0 0.0 Copell Airline,Dr//Page: 10 pole Utility ACME Utility Inspection Services, Inc. 2105 Waterview Pkwy., Richardson, TX 75080 44 ' Tel. 972-247-7741 ecri°"Lrvico. acmeinspection@yahoo.com Inspection report Date: Work Order: Surveyed By: Certificate Number: Pipe Segment Ref. : Section Number. : 11/20/2017 Default Jesus Alvarado U-206-2298 7-8 11 Weather: Pre-cleaning : Direction: Pipe Joint Length: Total Length: Length Surveyed: Dry No Pre-Cleaning Downstream 14.0 643.0 643.0 City: Copell Drainage Area: Upstream MH : 7 Street: Airline,Dr Media Label : Up Rim to Invert: 0.0 Location Code: Main highway-suburban/rural Flow Control: Not Controlled Downstream MH : 8 Location Details: Sheet Number: Down Rim to Invert: 0.0 Pipe shape: Circular Sewer Use: Sanitary Pipe size: 10 Pipe material: Polyvinyl Chloride Purpose: Pre-Rehabilitation Survey Lining Method: Owner: Additional Info: Line-East 1:5616 Distance Code Observation Grade 7 el 0.00 AMH Manhole/7 Line-East 0.00 MWL Water Level, 70%of cross sectional area 5.00 MGO General Observation/Survey Begins it S 643.00 MSA Survey Abandoned/Ran Out Of Cable On Wheel 8 QSR I QMR I SPR I MPR I OPR I SPRI I MPRI I OPRI 0000 0000 0.0 0.0 0.0 0.0 0.0 0.0 Copell Airline,Dr//Page: 11 (x.tne UtiNty ACME Utility Inspection Services, Inc. �� 2105 Waterview Pkwy.,Richardson, TX 75080 Tel. 972-247-7741 HWI rvlce5" acmeinspection@yahoo.corn Inspection report Date: Work Order: Surveyed By: Certificate Number: Pipe Segment Ref. : Section Number. : 11/20/2017 Default Jesus Alvarado U-206-2298 7-8 12 Weather: Pre-cleaning : Direction: Pipe Joint Length: Total Length: Length Surveyed: Dry No Pre-Cleaning Upstream 14.0 87.0 87.0 City: Copell Drainage Area: Upstream MH : 7 Street: Airline,Dr Media Label : Up Rim to Invert: 0.0 Location Code: Main highway-suburban/rural Flow Control: Not Controlled Downstream MH : 8 Location Details: Sheet Number: Down Rim to Invert: 0.0 Pipe shape: Circular Sewer Use: Sanitary Pipe size: 10 Pipe material: Polyvinyl Chloride Purpose: Pre-Rehabilitation Survey Lining Method: Owner: Additional Info: Reverse Set Up Tv.To Were Cable Ran Out/Line-East 1:760 Distance Code Observation Grade 8 et 0.00 AMH Manhole/8 Line-East so 0.00 MWL Water Level, 70%of cross sectional area 5.00 MGO General Observation/Survey Begins 0 87.00 MSA Survey Abandoned/Tv,To Were Cable Ran Out 7 QSR I QMR I SPR I MPR I OPR I SPRI I MPRI I OPRI 0000 0000 0.0 0.0 0.0 0.0 0.0 0.0 Copell Airline,Dr//Page: 12 Pane utility ACME Utility Inspection Services, Inc. 2105 Waterview Pkwy.,Richardson, TX 75080 4)s0F(-rio ,�65,�a`.. Tel. 972-247-7741 acmeinspection@yahoo.corn Inspection report Date: Work Order: Surveyed By: Certificate Number: Pipe Segment Ref. : Section Number. : 11/20/2017 Default Jesus Alvarado U-206-2298 8-9 13 Weather: Pre-cleaning : Direction : Pipe Joint Length : Total Length : Length Surveyed: Dry No Pre-Cleaning Downstream 14.0 643.0 643.0 City: Copell Drainage Area: Upstream MH: 8 Street: Airline,Dr Media Label: Up Rim to Invert: 0.0 Location Code: Main highway-suburban/rural Flow Control : Not Controlled Downstream MH: 9 Location Details: Sheet Number: Down Rim to Invert: 0.0 Pipe shape: Circular Sewer Use: Sanitary Pipe size: 10 Pipe material: Polyvinyl Chloride Purpose: Pre-Rehabilitation Survey Lining Method : Owner: Additional Info: Line-East 1:5616 Distance Code Observation Grade 8 1 111 0.00 AMH Manhole/8 Line-East 0.00 MWL Water Level, 75%of cross sectional area 5.00 MGO General Observation/Survey Begins 0 { 643.00 MSA Survey Abandoned/Ran Out To Cable On Wheel 9 QSR 1 QMR I SPR 1 MPR I OPR I SPRI I MPRI 1 OPRI 0000 0000 0.0 0.0 0.0 0.0 0.0 0.0 Copell Airline,Dr//Page: 13 • - € Utility ACME Utility Inspection Services, Inc. hw� 2105 Waterview Pkwy., Richardson, TX 75080 �o� v,.• Tel. 972-247-7741 f`H°n sr ' acmeinspection@yahoo.com Inspection report Date: Work Order: Surveyed By: Certificate Number: Pipe Segment Ref. : Section Number. : 11/20/2017 Default Jesus Alvarado U-206-2298 Souht Line-4-4 14 Weather: Pre-cleaning : Direction: Pipe Joint Length : Total Length : Length Surveyed: Dry Jetting Upstream 14.0 50.0 50.0 City: Copell Drainage Area : Upstream MH : Souht Line-4 Street: Airline,Dr Media Label : Up Rim to Invert: 0.0 Location Code: Main highway-suburban/rural Flow Control: Not Controlled Downstream MH : 4 Location Details: Sheet Number: Down Rim to Invert: 0.0 Pipe shape: Circular Sewer Use: Sanitary Pipe size: 8 Pipe material: Polyvinyl Chloride Purpose: Pre-Rehabilitation Survey Lining Method : Owner: Additional Info: Line-Souht-4 1:437 Distance Code Observation Grade 4 e0.00 AMH Manhole/4 Line-Souht 4 ' 0.00 MWL Water Level,40%of cross sectional area 5.00 MGO General Observation/Survey Begins 1'P S 50.00 ADP Discharge Point/Reached Stopping Point/Line Souht 4 Souht Line-4 QSR i QMR I SPR I MPR I OPR 1 SPRI I MPRI I OPRI 0000 0000 0.0 0.0 0.0 0.0 0.0 0.0 Copell Airline,Dr II Page: 14 • pole UtilityACME Utility Inspection Services, Inc. 2105 Waterview Pkwy., Richardson, TX 75080 4v s, Tel. 972-247-7741 °ecao„ „„rco" acmeinspection@yahoo.corn Inspection report Date: Work Order: Surveyed By: Certificate Number: Pipe Segment Ref. : Section Number. 11/20/2017 Default Jesus Alvarado U-206-2298 5 Souht-5 15 Weather: Pre-cleaning : Direction: Pipe Joint Length : Total Length: Length Surveyed Dry No Pre-Cleaning Downstream 5.0 61.0 61.0 City: Copell Drainage Area : Upstream MH : 5 Souht Street: Airline,Dr Media Label: Up Rim to Invert: 0.0 Location Code: Main highway-suburban/rural Flow Control: Not Controlled Downstream MH : 5 Location Details : Sheet Number: Down Rim to Invert: 0.0 — Pipe shape: Circular Sewer Use: Sanitary Pipe size: 8 Pipe material: Clay Tile(not vitrified clay) Purpose: Pre-Rehabilitation Survey Lining Method: Owner: Additional Info: Line-Souht 5 1:533 Distance Code Observation Grade 5 Souht e0.00 AMH Manhole/Souht-5 I0.00 MWL Water Level, 15%of cross sectional area 5.00 MGO General Observation/Survey Begins e61.00 AMH Manhole/5 5 QSR i QMR i SPR I MPR I OPR I SPRI ( MPRI I OPRI 0000 0000 0.0 0.0 0.0 0.0 0.0 0.0 Copell Airline,Dr II Page: 15 pole Utility ACME Utility Inspection Services, Inc. °k2105 Waterview Pkwy.,Richardson, TX 75080 ' Tel. 972-247-7741 Sd°°SE'�"g5 acmeinspection@yahoo.com Inspection report Date: Work Order: Surveyed By: Certificate Number: Pipe Segment Ref. : Section Number. : 11/20/2017 Default Jesus Alvarado U-206-2298 2-3 16 Weather: Pre-cleaning : Direction : Pipe Joint Length: Total Length : Length Surveyed: Dry Jetting Downstream 14.0 7.4 7.4 City: Copell Drainage Area: Upstream MH : 2 Street: Airline,Dr Media Label: Up Rim to Invert: 0.0 Location Code: Main highway-suburban/rural Flow Control : Not Controlled Downstream MH : 3 Location Details: Sheet Number: Down Rim to Invert: 0.0 Pipe shape: Circular Sewer Use: Sanitary Pipe size: 10 Pipe material: Polyvinyl Chloride Purpose: Pre-Rehabilitation Survey Lining Method: Owner: Additional Info: Line-West 1:65 Distance Code Observation Grade 2 gaggiiiciaggliali e 0.00 AMH Manhole/2 Line-West 0.00 MWL Water Level, 90%of cross sectional area 7.40ft//00:01:40.42// 5.00 MGO General Observation/Survey Begins I S 7.40 MSA Survey Abandoned/Water Level To High Camera Not Go 3 QSR I QMR I SPR I MPR I OPR I SPRI ] MPRI I OPRI 0000 0000 0.0 0.0 0.0 0.0 0.0 0.0 Copell Airline,Dr//Page: 16 • • 1� Pone ut►►ity ACME Utility Inspection Services, Inc. sNeWf rvK vl ez�` 2105 Waterview Pkwy.,Richardson, TX 75080 u Tel. 972-247-7741 acmeinspection@yahoo.com City Street Date Pipe Segment Reference Copell Airline,Dr 11/20/2017 2-3 Fur Iii f„n,"I W,�I �r I -, t H 7h I dfil-r.7 Nei P I,., IJUU i-•IHI 2-3_ce2383e5-218b-4b77-a0fd-c05bb6b37ec3_20171120_17 5056_873.jpg,00:01:40,7.40 Survey Abandoned/Water Level To High Camera Not Go Page 17 P�me utility ACME Utility Inspection Services, Inc. �� 2105 Waterview Pkwy.,Richardson, TX 75080 4N5ec-non tr,Aces. Tel. 972-247-7741 acmeinspection@yahoo.corn Inspection report Date: Work Order: Surveyed By: Certificate Number: Pipe Segment Ref. : Section Number. : 11/20/2017 Default Jesus Alvarado U-206-2298 2-3 17 Weather: Pre-cleaning : Direction: Pipe Joint Length: Total Length : Length Surveyed: Dry No Pre-Cleaning Upstream 14.0 399.1 399.1 City: Copell Drainage Area : Upstream MH : 2 Street: Airline,Dr Media Label: Up Rim to Invert: 0.0 Location Code: Main highway-suburban/rural Flow Control : Not Controlled Downstream MH : 3 Location Details : Sheet Number: Down Rim to Invert: 0.0 Pipe shape: Circular Sewer Use: Sanitary Pipe size: 10 Pipe material: Polyvinyl Chloride Purpose: Pre-Rehabilitation Survey Lining Method: Owner: Additional Info: Reverse Set Up Line-West 1:3486 Distance Code Observation Grade 3 0.00 AMH Manhole/3 Line-West 0.00 MWL Water Level, 80%of cross sectional area 5.00 MGO General Observation/Survey Begins 213.30 MCU Camera Underwater/Water Level To High 1 e399.10 AMH Manhole/2A-West Not On Map 2 QSR 1 QMR f SPR I MPR I OPR I SPRI I MPRI I OPRI 0000 0000 0.0 0.0 0.0 0.0 0.0 0.0 Copell Airline,Dr//Page: 18