Petterson (Encore)-CS180105
DrewDonosky 1/05/2018 CLAYMOOREENG,INC. 1903CentralDrive,Ste.406 Bedford,Texas76021 Phone:817.281.0572 o o o o o o o o o o o o ® SUBMITTAL INFORMATION Brass Saddles - (202B-xxx-xxx style) 202B DOUBLE STRAP BRASS SADDLES Brass nuts EPDM Gasket Silicon bronze straps N OM. P IPE O.D.A PPROX.C ATALOG S UBMITTED S IZE R ANGE W T. L BS.N UMBER I TEM(S) 4.80 - 5.406.6 202B-540-Tap *4"4.80 - 5.107.3 202B-510-Tap 5.10 - 5.407.3 202B-540-Tap 6"6.90 - 7.507.7 202B-750-Tap 8"9.05 - 9.628.8 202B-962-Tap 10"11.10 - 12.1210.7 202B-1212-Tap 12"13.20 - 14.3811.8 202B-1438-Tap 14"15.30 - 16.2518.0 202B-1625-Tap 16.30 - 17.2519.1 202B-1725-Tap 16"17.40 - 18.4023.0 202B-1840-Tap 18.50 - 19.2524.0 202B-1925-Tap 18"19.50 - 20.5025.0 202B-2050-Tap 21.20 - 22.2025.5 202B-2220-Tap 20" 22.50 - 23.5025.7 202B-2350-Tap 23.80 - 24.8026.0 202B-2480-Tap 24" 25.60 - 26.5026.5 202B-2650-Tap 30"31.74 - 32.7427.0 202B-3274-Tap UL Classified to ANSI/NSF Standard 61. O UTLET T AP C ODE IP T HREAD CC (AWWA) TCC (AWWA) T HREADHREAD T HREAD C ODE N UMBER T HREAD C ODE N UMBER S UBMITTED I TEM(S) S UBMITTED I TEM(S) 3/4” IPIP3 3/4” CCCC3 1” IPIP4 1” CCCC4 1-1/2” IPIP6 1-1/2” CCCC6 2” IPIP7 2” CCCC7 *Please Note: 4" Saddles with 2" taps have a limited range. Specifically, 4.80 - 5.10 or 5.10 - 5.40. All other tap sizes have the standard 4.80 - 5.40 range. To Order: Select the catalog number for the desired pipe range and complete the catalog number by adding the outlet thread tap code. Example: A double strap saddle for 6.90 D.I. pipe with a 3/4" CC thread would be 202B-750-CC3. FEATURES • All brass conforms to AWWA Standard C800 (ASTM B-62 and/or ASTM B-584, UNS NO C83600 - 85-5-5-5) • Straps are 5/8" high quality silicon bronze flattened to provide a wider bearing surface against pipe. • Gasket is EPDM rubber ASTM D2000 The Ford Meter Box Company considers the information in this submittal form to be correct at the time of publication. Item and option availability, including specifications, are subject to change without notice. Please verify that your product information is current. Submitted By: The Ford Meter Box Company, Inc. P.O. Box 443, Wabash, Indiana U.S.A. 46992-0443 Phone: 260-563-3171 / Fax: 800-826-3487 Overseas Fax: 260-563-0167 http://www.fordmeterbox.com 10/22/07 SUBMITTAL INFORMATION Corporation Stops - (F1000-x-G-NL style) AWWA/CC TAPER THREAD INLET BY GRIP JOINT FOR COPPER OR PLASTIC TUBING (CTS) OUTLET Solid one piece tee-head and keyBody Outlet ThreadsBeveled EPDM rubber gasket provides hydraulic seal Nylon Washer Phosphorous Bronze Gripper Ring for axial restraint AWWA/CC Threads Grip Joint Nut InletOutlet Length V ALVE B ODY O UTLET A PPROX.P ART S UBMITTED V ALVE S IZE I NLET S IZE O UTLET S IZE L ENGTH T HREADS W T. L BS N UMBER I TEM(S) 5/8” 5/8”3/4”3-1/2”3/4” Flare Copper1.4F1000-23-G-NL 3/4” 3/4”3/4”3-3/4”3/4” Flare Copper1.7F1000-3-G-NL 3/4” 3/4”1” 3-7/8”1” Flare Copper1.9F1000-34-G-NL 1” 1”1” 4-9/16”1” Flare Copper2.7F1000-4-G-NL 1” 1”1-1/4” 4-5/8”1-1/4” Flare Copper3.2F1000-45-G-NL Note:Ford recommends using insert stiffeners with plastic pipe or tubing. FEATURES • All brass that comes in contact with potable water conforms to AWWA Standard C800 (UNS NO C89833) • The product has the letters "NL" cast into the main body for proper identification • UL Classified to ANSI/NSF Standard 61 and Standard 61 Annex G (NSF/ANSI 372) • Brass components that do not come in contact with potable water conform to AWWA Standard C800 (ASTM B-62 and ASTM B-584, UNS NO C83600 - 85-5-5-5) • Body design provides larger, more rugged wrench flats for proper installation • Meets 100 PSI working pressure requirement of AWWA Standard C800 The Ford Meter Box Company considers the information in this submittal form to be correct at the time of publication. Item and option availability, including specifications, are subject to change without notice. Please verify that your product information is current. Submitted By: The Ford Meter Box Company, Inc. P.O. Box 443, Wabash, Indiana U.S.A. 46992-0443 Phone: 260-563-3171 / Fax: 800-826-3487 Overseas Fax: 260-563-0167 http://www.fordmeterbox.com 01/28/13 SUBMITTAL INFORMATION Angle Key Meter Valves - (KV43-xxxW-Q-NL style) QUICK JOINT FOR COPPER OR PLASTIC TUBING (CTS) INLET BY METER SWIVEL NUT OUTLET Bronze pin securely locks the Two phosphor bronze spring washers tee head to the inverted key under the tee head reseat the key after turning Sturdy stops allow 150° motion Bronze Snap Ring Padlock Wing for locking valve Meter Swivel Nut in closed position Drilled for Seal Wire Meter Coupling Thread EPDM Rubber Meter Gasket Buna-N O-ring in the inverted key Outlet External Nut Stop Height Molded Buna-N Spring Tip Gasket Provides Hydraulic Seal Quick Joint Nut Stainless Steel Gripper Inlet Length S ERVICE L INE M ETER S IZE A PPROX.P ART S UBMITTED V ALVE S IZE L ENGTH H EIGHT S IZE I NLET O UTLET W T. L BS N UMBER I TEM(S) 3/4" 3/4"5/8”x3/4” & 3/4" 1-11/16"1-21/32"1.6KV43-332W-Q-NL 3/4" 1"5/8”x3/4” & 3/4" 1-11/16"2-9/32"1.9KV43-342W-Q-NL 1" 1"1" 1-15/16"1-57/64"2.3KV43-444W-Q-NL Note: Ford recommends using insert stiffeners with plastic pipe or tubing. FEATURES • All brass that comes in contact with potable water conforms to AWWA Standard C800 (UNS NO C89833) • The product has the letters "NL" cast into the main body for proper identification • UL Classified to ANSI/NSF Standard 61 and Standard 61 Annex G (NSF/ANSI 372) • Brass components that do not come in contact with potable water conform to AWWA Standard C800 (ASTM B-62 and ASTM B-584, UNS NO C83600 - 85-5-5-5) • Padlock Wing for locking the valve in a closed position • Meets 100 PSI working pressure requirement of AWWA Standard C800 The Ford Meter Box Company considers the information in this submittal form to be correct at the time of publication. Item and option availability, including specifications, are subject to change without notice. Please verify that your product information is current. Submitted By: The Ford Meter Box Company, Inc. P.O. Box 443, Wabash, Indiana U.S.A. 46992-0443 Phone: 260-563-3171 / Fax: 800-826-3487 Overseas Fax: 260-563-0167 http://www.fordmeterbox.com 05/10/13 o o o o V1600-4 Frame Product Number 41600410 Design Features -Materials Gray Iron (CL35) -Design Load Heavy Duty -Open Area -Coating Undipped - Designates Machined Surface Certification -ASTM A48 - - -Country of Origin: USA Drawing Revision 3/8/2003Designer:SBB 4/12/2012Revised By:SDC Disclaimer Weights (lbs/kg), dimensions (inches/mm) and drawings provided for your guidance. We reserve the right to modify specifications without prior notice. CONFIDENTIAL: This drawing is the property of EJ Group, Inc. and embodies confidential information, registered marks, patents, trade secret information, and/or know how that is the property of EJ Group, Inc. Copyright © 2011 EJ Group, Inc. All rights reserved. Contact 800 626 4653 ejco.com GASKETED SDR35 SEWERFITTINGS • 4" - 15" • 12" - 48" • • LARGE DIAMETER MOLDED SDR35 SEWERFITTINGS • 12" - 15" • • HEAVY WALL SDR26 GASKETED SEWERFITTINGS • 4" - 12" 12" - 18" • • PVC SEWER FITTINGS|5 SPECIFICATION CHART SEWERFITTINGS PRESSUREFITTINGS 10|EASY SPECIFICATION CHART 1125 1125 December 1, 2017 Redi-Mix Concrete, L.LC a US Concrete Company To: CIP Concrete LLC The Technical Service Department 331 North Main St. Project: Peterson Addition - Coppell Euless, TX 76039 Office: (817) 835-4100 RedimixQC@us-concrete.com RE:Submittal Provisions www.us-concrete.com Enclosed you will find the necessary submittal documents for the referenced project above for your review. Redi-Mix’s strength guarantee per ASTM C94 will not be effective unless the field sampling has been done per ASTM C172 and ASTM C31 and the laboratory testing fully complies with ASTM C39 and ASTM C1077. Redi-Mix will also guarantee the strength performance of the mix designs submitted for a concrete temperature between 55°F and 95°F provided the design plastic properties are not exceeded and the concrete is placed within 90 minutes of batch time. This concrete temperature range shall not supersede any more restrictive temperature specification. All concrete should be placed and cured with the appropriate ACI guidelines and recommendations for hot and cold weather concreting.Redi-Mix cannot be responsible for non-conformance of strength if cylinders are not cured per ACI 301, section 1.6.3.2.d. Hot weather concreting practices will require the purchaser to order ice and/or chilled water to meet concrete temperature specifications. The purchaser shall be responsible for precautions taken against excessive wind, heat and low humidity per ACI 305 guidelines. The purchaser shall assume responsibility for any concrete defects related to the finishing process (cracking, scaling, dusting, delamination, discoloration, etc.), which is beyond Redi-Mix’s control. This includes proper preparation, compaction and wetting of subgrade as well as proper spacing and depth of joints and rebar. During periods of cold weather, all concrete surfaces should be protected from freezing for at least the first 24 hours after placement to allow the concrete to attain a compressive strength of 500 psi. Should the purchaser elect not to order temperature control measures, the purchaser shall then assume all liability for costs associated with rejected concrete due to non-compliant concrete temperature. According to ACI 304.2R Section 4.2.1 “Placing Concrete by Pumping Methods”, the inside diameter of the hose should be a minimum of 3 times the maximum angular aggregate size of the concrete. (ASTM C33 allows #57LS to have up to 5% retained on the 1” sieve). It is recommended to minimize or eliminate the free fall of concrete to avoid loss of air content. Depending on boom configurations, alterations to the mix design may be required. With regard to pumped concrete, the various boom configurations, length of hose, line reductions and free fall distance are beyond Redi-Mix’s control and we therefore cannot be responsible for loss of air content or any costs associated with either rejected fresh concrete or the removal and replacement of hardened concrete due to non-compliant air content resulting from this or from placing concrete outside of the slump range specified on the mix design. We thank you for allowing us to submit these documents for your review. Please copy Redi-Mix with the approved submittal. The approved submittal allows Redi-Mix to review any notes, comments or exceptions made by the engineer or owner relating to the specification. Failure to notify us prior to first placement shall constitute acceptance of the submitted mix designs and submittal provisions. Please order by mix number when scheduling concrete delivery. We request that Redi-Mix be added to the list of names receiving copies of testing laboratory information for this project. ASTM C94 entitles a manufacturer to receive copies of all test reports when strength of concrete is used as a basis for acceptance. This information is another tool for Redi-Mix to review and monitor the quality and performance of the concrete product delivered. In the event of limited material availability, substitution of a similar performing material may be required. All substituted materials will meet the appropriate ASTM requirements. In order to maintain the required mix volume, weights of individual materials may be varied to accommodate different material specific gravities. Material certifications for substituted materials are available upon request. The information within this submittal is confidential and the exclusive property of Redi-Mix. It shall not be disseminated to third parties without written permission from Redi-Mix Concrete. Please contact Technical Services with any questions at (817) 835-4077. Respectfully, Daniel Jeray Technical Services Manager THE NEW RESOURCE FOR THE CONSTRUCTION INDUSTRY Date:12/1/2017 Mix Number:10M11504 Redi-Mix Concrete, L.P. A US-Concrete Company Strength:4200psi @ 28 days 331 N.Main St Euless, TX 76039 Description:6.5 SK NR/NA Technical Service: (817)-835-4187 Plant No.: 259 Dispatch: (817) 835-4020 E-mail: redimixqc@us-concrete.com Customer:CIP Concrete LLC www.us-concrete.com Project:Peterson Addition - Coppell Usage:Inlets & Paving SaturatedSurfaceDryWeightsPerCubicYard Vol MaterialSourceQuantity (ft^3) ASTM C150 Type l/ll CementMartin Marietta, Midlothian611lb3.11 .1 1 00.00 3 ASTM C33 No. 57 LSMartin Marietta, Bridgeport1850lb11.19 ASTM C33 Fine AggregateRedi-Mix Concrete1241lb7.62 3 ASTM C494 A&D NRWR/B&D NRWR RetarderBASF Pozzolith322 / MasterSet R 3000-5oz/cwt ASTM C260 Air EntrainmentBASF MasterAir AE90/*Fritz SuperAir Plusoz/cwt0-41.08 30gal4.00 Total Volume:27.00 Specified SlumpSpecified Air Percent: 4+/- 1"4.5+/- 1.5% Wet Unit Weight:146.4lb/ft^3Design w/(c+p) ratio:0.41 The use of an EF Technology mix design will reduce the amount of CO2 entering the atmosphere, thereby reducing potential global warming. "Your Project, Our World" Notes:Please make sure that redimixqc@us-concrete.com is on the list to receive break reports. Admixtures may be adjusted, depending on ambient conditions, at time of placement. *Air Entrainment may be adjusted using Fritz Super Air Plus This mix has been designed to meet the requirements of this project based on the information sent to Redi-mix Concrete. It is the responsibility of the purchaser to determine whether this mix design meets project specifications and is appropriate for the anticipated environment conditions. The specified strength guarantee per ASTM C94 will not be effective unless field sampling has been done per ASTM C172 and ASTM C31 and the laboratory fully complies with ASTM C39 and ASTM C1077. In the event of limited material avaliability, substitution of a similar performing material may be required. All substituted materials will meet the appropriate ASTM requirements. In order to maintain the required mix volume, weights of individual materials may be varied to accommodate different material specific gravities. Material certifications for substituted materials are avaliable upon request. All Redi-Mix Concrete mix designs are proprietary and confidential. The information contained in this submittal is only intended for parties associated with this project to validate the mix design materials, properties and its performance. Use of this submittal for other purposes without permission or consent from Redi-Mix Concrete is strictly prohibited. THE NEW RESOURCE FOR THE CONSTRUCTION INDUSTRY BLENDED FINE AGGREGATE GRADATION 70% Concrete Sand 30% Manufactured Sand Source:REDI-MIX CONCRETE, PLANT259 Product:Fine Aggregate, ASTM C33 Section 5.1 Sample Date:9/11/17 Report Date:9/29/17 Tested by:WCH ASTM TxDOT SPEC'S SPEC'S Percentage Sievemm%Ret%Pass-- 1 1/238.100100-- 125.400100 3/4"19.000100100100 1/2"12.700100100100 3/8"9.510100100100 #44.7 649695-10095-100 #82.38208080-10080-100 #1 61.19356550-8550-85 #300.60554525-6025-65 #500.30821805-3010-35 #1000.159460-100-10 Pan1000-- #200 (Decant)0.70-20-30-3 Additional Properties F.M.2.91 2.3 - 3.12.3 - 3.1 ABS%0.70% S.G.2.61 Dry Rodded Weight(lbs./c.f.)110.52 Tex 203FS.E.%89.14% Voids 38.75 Tex 408A OrganicImpurities Lighter Than Standard Tex 413A% Deleterious 0% Tex-612-JAcid Insolubility 81 Laboratory Manager SUPER AIR PLUS AIR ENTRAINING ADMIXTURE Cementitious content, concrete temperature, ambi- ADVANTAGES ent temperature or concrete mixes containing ac- • Reduces amount of concrete rejected due to low celerators, retarders, or special admixtures such as entrained air content superplasticizers or silica fume may require dosage • Super Air Plus is a premeasured dry material and rates outside the recommended range. Contact your will not freeze Fritz-Pak distributor with any questions concerning • Easily transported and dispensed the dosage rates for these products. It is recom- • Improves concrete workability mended that testing be done to determine the suit- • Addition of Super Air Plus will not affect the ability of Super Air Plus to your mix designs. water/cement ratio • Entrained air content may be easily adjusted FOR ONE YARD TRAILER MIXERS: prior to job site testing Use specially packaged product in 4 oz. water-solu- • Super Air Plus is packaged in water-soluble Fritz- ble bags. (Item #95661). Pak inner bags for convenient use at plant or job site. FOR MORTARS AND DRY BLENDED PRODUCTS: DESCRIPTION Super Air Plus can be used as an air entraining agent Fritz-Pak Super Air Plus is a dry powdered admix- for the production of mortars and other dry blended ture, packaged in patented ready-to-use water-sol- materials. Up to 16% air entrainment can be obtained uble bags or in bulk (50 lb bags). Super Air Plus is with Super Air Plus. Air contents vary considerably recommended for all types of air entrained concrete depending on the materials used. Use the following when an increase in entrained air content is neces- table as a guideline: sary. Super Air Plus may also be used as a primary air-entraining admixture. Super Air Plus is compat- ible with all standard concrete admixtures. Dosage of Desired Super Air PlusBy total weight Air By weight of of blend DIRECTIONS Content cement 1. If entrained air content is below the specifi ed level, 0.25-1.25 oz/cwt0.9-4.5 oz/ton determine which Air Plus product is required. (See 5-7% 0.15-0.80 g/kg28-141 g/MT Recommended Dosage Rate). 1.0-4.0 oz/cwt5.0-12.0 oz/ton 2. Each Super Air Plus package is double bagged. 7-10% 0.63-2.5 g/kg156-375 g/MT Remove the protective outer bag and add the water- soluble Fritz-Pak inner bag to plastic concrete. 4.0-6.0 oz/cwt14.0-22.0 oz/ton 10-15% The entire inner bag will easily dissolve. 2.5-3.75 g/kg438-688 g/MT 3. Mix at high speed for 5 to 7 minutes to insure that the Super Air Plus is uniformly dispersed COMPATIBILITY throughout the mix. Super Air Plus is compatible with all air-entraining 4. If entrained air content remains below specifi ed admixtures, calcium chloride and other admixtures. levels, more Super Air Plus may be added. When used with other admixtures, each one must be dispensed separately into the mix. RECOMMENDED DOSAGE RATE APPLICABLE STANDARDS FOR CONCRETE: Super Air Plus meets ASTM C-260, AASHTO M-154 & CRD C-13 specifi cations. Super Air Plus. For larger increases in entrained air content, use one 8-oz bag (227 g) of Super Air Plus PACKAGING to increase the entrained air content for a full load • 8-oz. (227 grams) water soluble bag, 60 bags of concrete by ¾ to 2%. For use as a primary air- per case, 35 cases per pallet (item #95664) entraining admixture, a Super Air Plus dosage rate • 50-lb paper bag, 40 bags per pallet (item of 0.25 to 1.25 oz./cwt. (0.15 to 0.80 g/kg) is recom- #95667) mended to achieve 5 to 7% entrained air content. Fritz-Pak Corporation • Mesquite, TX USA • Tel: 214-221-9494 • Fax: 214-349-3182 • www.fritzpak.com Product Bulletin #124 43 SUPER AIR PLUS AIR ENTRAINING ADMIXTURE Q. What is the raw material used in the production of Super Air Plus? A. Vinsol Resin, a natural air entrainer. Q. Are these products compatible with synthetic air entrainers? A. Yes. Additionally the spacing and size of air bubbles is improved when natural air entrainers are used to correct synthetic air entrainers. Q. Can they be used in dry-blended materials like mortars and stuccos? A. Yes. See the recommended dosage rate chart. Q. Are Super Air Plus and Air Plus effective in concrete with fl y ash containing high levels of • 4-oz. water soluble bag, 60 bags per case, 35 organic compounds (i.e. high LOI)? cases per pallet (item #95661) A. Yes. Natural air entrainers are more effective than synthetic air entrainers. FAQs Q. Can I add Super Air Plus or Air Plus to water to Q. What does increased air content do to make a liquid admixture? concrete? A. No. Some of the components will only dissolve A. It increases its durability by making it more under special conditions of temperature and pH. resistant to damage from freezing. Q. How long have the products been in the Q. Will it change the set time? market? A. No, it will not speed or slow the set. A. Since 1992. Q. What standards does Super Air Plus meet? A. They meet ASTM C-260, AASHTO M-154 and PRECAUTIONS CRD C-13 standards. All Fritz-Pak Concrete Admixtures should be stored in a dry location, protected from breakage, deterioration Q. Will it affect the strength of my concrete? and contamination. They are not subject to damage A. It will not signifi cantly change strength, and it from freezing temperatures. will increase durability. WARRANTY Q. What is the difference between Super Air Plus The information and recommendations in this publication are, to the best of our knowledge, reliable. Suggestions made concerning uses and Air Plus? or applications are only the opinion of Fritz-Pak Corporation and us- A. Super Air Plus has twice the concentration of ers should make their own tests to determine the suitability of these the active ingredient of Air Plus. products for their own particular purposes. Because of numerous factors affecting results, Fritz-Pak Corporation makes no warranty of any kind, expressed or implied, including those of merchantability Q. Which product should I use, Air Plus or Super andfi tness for purpose. Statements herein, therefore, should not Air Plus? be construed as representations or warranties. The responsibility of A. Air Plus should be used by concrete producers Fritz-Pak Corporation for claims arising out of breach of warranty, who have very consistent quality in their supply negligence, strict liability, or otherwise are limited to the purchase price of the materials. of raw materials, thus only needing small corrections of air. Concrete producers that U.S. Patents No. 4,961,790 and No. 5,120,367. have variation in their quality of raw materials normally experience wider fl uctuations in air © 2009 Fritz-Pak Corporation content and should consider using Super Air Plus. Fritz-Pak Corporation • Mesquite, TX USA • Tel: 214-221-9494 • Fax: 214-349-3182 • www.fritzpak.com Product Bulletin #124 44