Freeport NIP(2.4)-LR 970729 (2) GEOTECHNICAL AND I r~ ~ r~ LJ P ENVIRONMENTAL CONSULTANTS REPORT OF REINFORCING STEEL PLACEMENT OBSERVATION Derse Exhibits Royal Lane, North of Bethel Road Coppell, Texas REPORTED TO: Raymond Construction Company 2775 Villa Creek, Suite 230 Dallas, Texas 75234-7419 ATTN; Mr. Todd Hanson REPORT NO. 8 REPORT DATE: 07-29-97 REG PROJECT NO. 3544 DATE OBSERVED: 07-10-9 TECHNICIAN: C. Thompson CONTRACTOR: Raymond Construction Company Floor Slab from Grid Lines 3 to 5 - entire width of building. Sheet S-1.0 construction joint details; Sheet S-2.0 reinforcing steel note. The following deviations were observed: 1. Reinforcing steel is not supported by chairs; according to Sheet S-2.0, steel should be 1-1/2" down from top of concrete. 2. Twenty -four (24) gauge keyway is missing from construction joints that is called for on Sheet S-1.0. These deviations were brought to the attention of Jerome Baldwin. These deviations were X corrected __ not corrected No deviations were observed. All reinforcing steel appeared to be placed in accordance with contract documents & CRSl. 2424 STUTZ DR.- SUITE 400. DALLAS, TX 75235 · TEL[214] 350 5600 · FAX[214] 350 0019 Distribution: (1) Raymond Construction Company/ Mr. Todd Hanson (1) Mullen & PowelI-Technistructures/ Mr. Dennis Gant (1) Mayse - Kaiser & Associates/ )Cr. Greg Daspit ity of Coppell/Mr. Larry Davis (1) City of Coppell/Mr. Lee Stone Submitted by: REED ENGINEERING GROUP, INC. Original Signed By Ronald F. Reed, P.E. RFR/kff