Georgetown Plaza-CS 860515GINN, INC.
CONSULTING ENGINEERS
GEORGETOWN PLAZA
PUNCH LIST
Existing valve stack for Mockingbird cemented in by paving contractor.
Dirt in stack.
J2. Water meter for landscaping~raise and bring to grade~
3. Backfill curb at fire hydrant.
/4. Fire hydrant leaking.
Locking mechanism for round meter box.
6. Fire hydrant leaking. ~ ~
7. Replace/raise 8" valve stack. ~ ~ ~'¢*/~¢ ~&
Inlet throat rough -- rejected.
Need fire hydrant valve cap.
N. 10. Grade dirt from around fire hydrant.
11. Clean trash piles and concrete piles.
fl2. 6' combination inlet -- needs dirt graded for proper drainage.
13. 6' combination inlet -- epoxy/grout honeycomb in walls.
~14. Strip forms in future driveway and backfill.
/15. Remove broken concrete curbs from site.
16. Curb and gutter section in future drive uplifted -- remove and replace.
~17. Route and seal construction Joints to handicap ramps in future drive.
~18. Inlet throat not to specifications -- opening not wide enough inside forms.
/
-~9. Inlet throat too rough -- concrete slober on inlet face and top - no
expansion material.
~0. Inlet throat rejection -- concrete in invert -- forms in side -- cover
missing.
21. First manhole -- dirt in inlet -- pull nails out of walls~~
22. Second manhole -- wood in neck -- dirt in invert -- bricks turned wrongw
way in adj. neck.~i~ ~ /
23. Third manhole -- brick in invert -- wood in neck adjustment -- brick
16135Preston Road · Sukel06,Dalla$,Tex~ 75248 * Phon¢214/~86-(~ll
24. -~mr~th manhole -- recheck can't locate.
j25.~- concrete and debris in back lot (private property) remove from
J26. Temporary electrical pole -- aerial drop over parking lot too iow.
27.J Traffic channelization devices for Samuels Boulevard.