REPORT OF
CONCRETE COMPRESSIVE STRENGTH
CLIENT: Larry Jackson Construction Co.
5112 Sun Valley
Fort Worth, TX 76119
PROJECT: GEORGIAN PLACE
CITY OF COPPELL
PAGE 1 OF
PROJECT NO.: 9711048
REPORT NO.: 904460
DATE OFSERVICE:10/20/1999
AUTHORIZATION:
REPORTDATE: 11/17/1999
SERVICES: Sample concrete at location of placement, perform required field tests,
prepare and test concrete compressive strength specimens.
PROJECT DATA
CONTRACTOR: Larry Jackson Construction Co.
CONCRETE SUPPLIER: Pioneer
PLANT: 27
SPECIFICATION REQUIREMENTS
STRENGTH: 4500psi @ 28 DAYS
MEI~OD OF TEST
SAMPLING:
MOLDING & CURING:
SLUMP:
TEMPERATURE:
AIR CONTENT:
UNIT WEIGHT:
CAPPING/PADS:
TESTING:
AIR: 4%
ASTM C172
ASTM C31
ASTM C143
A~TM C1064
ASTM C231
ASTM C617
ASTM C39
CYLINDER
MARKED
SET NO.
1 1
1 2
1 3
1 4
CLASS OF CONCRETE: 7725
DATE OF PLACEMENT: 10/20/1999
TIMESAMPLED: 02:20PM BY: Jeremy Meek
TEMPERATURE (Deg~ - AIR: 76 CONCRETE: 75
TRUCKNO: 758 TICKETNO: 415896
MEASURED SLUMP (in.): 3.50
AIR CONTENT(%): 5.0
LOCATION OF PLACEMENT:
Inlet and Curb
south entrance to Georgian Dr.
ist inlet south side.
REPORT OF TESTS
CONCRETE COMPRESSIVE STRENGTH - 6 X 12 CYLINDERS
MAXIMUM COMPRESSIVE
DATE AGE DIAMETER AREA LOAD STRENGTH
TESTED (~) (m.) ~q.m.) 0~. forc~
10/27/1999 7 6.00 28.27 113870 4030
10/27/1999 7 6.00 28.27 116110 4110
11/17/1999 28 6.00 28.27 131240 4640
11/17/1999 28 6.00 28.27 138030 4880 CONE
FRACTURE TYPE RENDkRKS
CONE
CONE
CONE
Technkian: Jeremy Meek Started: 01: 00PM
CME Technician
Report Distribution: (2) ~ Jad~M Comm~6o. Co.
(1) City of Co~gell
100l RTB
Stopped: 03:30PM
~HNOLOGIES INC.
Tim- Begole, CET.
Office Manager
app y omy to me sample tested an~o~ mspecteo, and am n~ indicative of the quantities of appate~y ~ ~ s~ ~.