Georgian Place-LR 991116TECHNOLOGIES INC
Maxim Technologies Inc.
2200 Gravel Drive
Fort Worth, Texas 76118-7123
Telephone: (817) 284-7755
FAX: (817) 589-1420
REPORT OF
CONCRETE COMPRESSIVE STRENGTH
CLIENT: Larry Jackson Construction Co.
5112 Sun Valley
Fort Worth, TX 76119
PROJECT: Georgian Place
City of Coppell
PAGE 1 OF 1
PROJECT NO.: 9711048
REPORT NO.: 904434
DATE OF SERVICE: 10 / 19 / 1999
AUTHORIZATION:
REPORT DATE: 11/16/1999
SERVICES: Sample concrete at location of placemeht, perform required field tests,
prepare and test concrete compressive strength specimens.
PROJECT DATA
CONTRACTOR: Larry Jackson Construction Co.
CONCRETE SUPPLIER: PIONEER
PLANT: 27
SPECIFICATION REQUIREMENTS
STRENGTH: 4500psi @ 28 DAYS
SLUMP: 4"
METHOD OF TEST
SAMPLING:
MOLDING & CURhNG:
SLUMP:
AIR CONTENT:
UNIT WEIGHT:
CAPPING/PADS:
TESTING:
3.00%
ASTM C172
ASTM C792
ASTM C143
ASTM C1064
ASTM C231
ASTM C138
ASTM C617
ASTM C39
CYLINDER
MARKED
SET NO.
1 1
1 2
1 3
1 4
CLASS OF CONCRETE: 7725
DATE OF PLACEMENT: 10/19/1999
TIME SAMPLED: 02: 05 BY: Jeremy Meek
TEMPERATURE (1)egF) - AIR:80 CONCRETE: 75
TRUCKNO: 924 TICKETNO: 353700
MEASURED SLUMP (in.): 3.00
AIR CONTENT(%): 3.5
LOCATION OF PLACEMENT:
INLET TOPS 2N-D ENTRAi~CE TO GEORGINA DRIVE
INLET ON LEFT
REPORT OF TESTS
CONCRETE COMPRESSIVE STRENGTH - 6 X 12 CYLINDERS
MAXIMUM
DATE AGE D~METER AREA LOAD
TESTED (~ys) (~.) (sq.~.) (lbs.~rce)
10/26/1999 7 6.00 28.27 126650
10/26/1999 7 6.00 28.27 134520
11/16/1999 28 6.00 28.27 162580
11/16/1999 28 6.00 28.27 168270
COMPRESSIVE
STRENGTH
(psi)
4480
4760
5750
FRACTURE TYPE REMARKS
CONE
CONE
CONE
5950 CONE
1ST
Technician: Jeremy Meek Started:
CME Technician
Report Distribution:
(2) Larry Jackson Construction Co.
(1) City of Coppell
1001 T
01:30 Stopped: 03:30
~ Be~g~Ffe, CET.
Office Manager
Our letters and reports arc' for the exclusive use of the client to whom they are addressed and shall not b~ reproduced except in
full without the approval of the testing )aboratory. Th~ use o~' o~r n,3me ~ust receiye, our .written al~pr?al. Our let. to.r? and reports
apply only to th~ sample tested and/or inspected, and are nol indicative o{ th~ qualltltles ol apparently identical or similar products.