Georgian Place-LR 991101TECHNOLOGIES INC Maxim Technologies Inc. 2200 Gravel Drive Fort Worth, Texas 76118-7123 Telephone: (817) 284-7755 FAX: (817) 589-1420 REPORT OF CONCRETE COMPRESSIVE STRENGTH CLIENT: Larry Jackson Construction Co. 5112 Sun Valley Fort Worth, TX 76119 PROJECT: City of Coppell GEORGID_N PLACE PAGE 1 OF 1 PROJECT NO.: 9711048 REPORT NO.: 904106 DATE OF SERVICE: 10/04/1999 AUTHORIZATION: REPORT DATE: 11/01/1999 SERVICES: Sample concrete at location of placement, perform required field tests, prepare and test concrete compressive strength specimens. PROJECT DATA CONTRACTOR: Larry Jackson .Construction Co. CONCRETE SUPPLIER: PIONEER PLANT: 27 SPECIFICATION REQUIREMENTS STRENGTH: 4500psi @ 28 DAYS SLUMP: 3 AIR: 5 METHOD OF TEST SAMPLING: ASTM C172 MOLDING & CURING: ASTM C792 SLUMP: ASTM C143 TEMPERATURE: ASTM C1064 AIR CONTENT: ASTM C231 UNIT WEIGHT: ASTM C138 CAPPING/PADS: ASTM C617 TESTING: ASTM C39 , CLASS OF CONCRETE: 7725 DATE OF PLACEMENT: 10/04/1999 TLME SAMPLED: 08: 30 BY: Jeremy Meek TEMPERATURE (DegF) - AIR: 75 CONCRETE: 78 TRUCKNO: 648 TICKETNO: 353291 MEASURED SLUMP (in.): 5.50 AIR CONTENT(%): 5 LOCATION OF PLACEMENT: PAVING, STA 4+81 REPORT OF TESTS CONCRETE COMPRESSIVE STRENGTH - 6 X 12 CYLINDERS CYLINDER MARKED DATE AGE DIAMETER AREA SET NO. TESTED (days) (in.) (sq.in.) 1 1 10/11/1999 7 6.00 28.27 1 2 10/11/1999 7 6.00 28.27 1 3 11/01/1999 28 6.00 28.27 1 4 11/01/1999 28 6.00 28.27 MAXIMUM COMPRESSIVE LOAD STRENGTH (Ibs.~rce) (paT FRACTURE TYPE REMARKS 117600 4160 CONE 118440 4190 CONE 135280 4780 CONE 145930 5160 CONE Technician: Jeremy Meek Started: 06: 00 CME Technician Report Distribution: (2) LarG' Jackson Construction Co ( ) City of Coppell 100! T Stopped: 10:00 MAXIM TECHNOLOGIES INC. Tim gegole, CET. Office Manager Our ]e. tters and reports axe for the exclusive use of the c e it to whom they are addressed and sha not be reproduced except in full w~thout the approval of the testing labora ory The use of our name must receive our wr ten approval Our letters and reports apply only to the sample tested and/or inspected, and are not indicative of the quantities ofappaxemly identical or similar products.