Loading...
Georgian Place-LR 990917TECHNOLOGIES INC Maxim Technologies Inc. 2200 Gravel Drive Fort Worth, Texas 76118-7123 Telephone: (817) 284-7755 FAX: (817) 589-1420 CLIENT: PROJECT: SERVICES: REPORT OF CONCRETE COMPRESSIVE STRENGTH Larry Jackson Construction Co. 5112 Sun Valley Fort Worth, TX 76119 City of Coppell WHISPERING HILLS PAGE 1 OF 1 PROJECT NO.: 9711048 REPORT NO.: 903755 DATE OF SERVICE: 9/10/1999 AUTHORIZATION: REPORT DATE: 9/17/1999 Sample concrete at location of Placement, perform required field tests, prepare and test concrete compressive strength specimens. CONTRACTOR: CONCRETE SUPPLIER: PIONEER PLANT: 27 SPECIFICATION REQUIREMENTS STRENGTH: 4500psi @ 28 DAYS PROJECT DATA Larry Jackson Construction Co. CLASS OF CONCRETE: SLUMP: 5" AIR: 5% METHOD OF TEST SAMPLING: ASTM C172 MOLDING & CURING: ASTM C792 SLUMP: ASTM C143 TEMPERATURE: ASTM C1064 AIR CONTENT: ASTM C231 UNIT WEIGHT: -~S~v[ C138 ' CAPPING/PADS: ASTM C617 TESTING: AS '1~/ C39 CYLINDER MARKED DATE SET NO. TESTED 9/17/1999 9/17/1999 10/08/1999 7725 DATE OF PLACEMENT: 9/10/1999 TIME SAMPLED: 03: 00 BY: Jeremy Meek TEMPERATURE {DegF) - AIR: 95 CONCRETE: 96 TRUCK NO: 888 TICKET NO: 345580 MEASURED SLUMP (in.): 3.50 AIR CONTENT(%): 5.0 UNIT WEIGHT(pcf): N/A LOCATION OF PLACEMENT: INLETT SECTION D-D STA 1+09 REPORT OF TESTS CONCRETE COMPRESSIVE STRENGTH - 6 X 12 CYLINDERS MAXIMUM COMPRESSIVE AGE DIAMETER AREA LOAD STRENGTH {days) {in,) {sq.in.) Jibs. force) {psi) FRACTURE TYPE 7 6.00 28.27 135200 4780 CONE 7 6.00 28.27 127740 4520 CONE 28 REMARKS 10/08/1999 28 Technician: Jeremy Meek Started: CME Technician Repo~ Distribution: {2) Larry Jackson Construction Co. (1) City of Coppell 01:30 Stopped: 05:00 MAXI.~_ C .~LOGIES INC. Tim BegGle, CET. Office Manager Our otters and reports are for the exc us ve use of the c lent to whom they are addressed and shell not be reproduced except in full without the approval o! the testing laboratory. The usa of our name must receive our written al~xoval. Our letters eno reports apply only to the sample tested and/or inspected, and are not indicative of the quantities of apparently identical or similar products.