Georgian Place-LR 9802111341 West Mockingbird Lane · Dallas, Texas 75247 · 972.647.6700 · www. txi.com
Larry Jackson Construction
5112 Sun Valley Drive
Fort Worth, TX 76119
Attn: Mr. Larry Jackson
RE:
8204 8206 8274
The attached concrete mix designs utilizing the appropriate ASTM
C-33 or ASTM C-330 aggregate are proposed for use on the above
referenced project for ready-mixed concrete to be furnished by
TXI.
To ensure that the correct mix is delivered to your ~roject,
please order by the mix design number which appears in the upper
left hand corner of the mix design.
Texas Industries certifies that the above mix designs, when
ordered by specified design identity, and delivered by TXI, will
meet or exceed the indicated design strength at the designated
age when tested in accordance with the applicable and current
ASTM Standards C 31, C 39, C 78, C 172, C 293, applicable
provisions of C 94, and evaluated in accordance with applicable
provisions of ACI Building Code.
TXI would like to be included on your mailing list to receive all
test reports. ASTM C 94 entitles a manufacturer to receive
copies of all test reports when strength of concrete is used as a
basis for acceptance.
Please contact us if you have any questions or require any
additional information. Please notify TXI of approval of the
proposed mix designs prior to their use. Failure to notify us
prior to first placement shall constitute acceptance. To ensure
that the proper mix designs are ordered, please send a copy of
this letter, after approval, to the above referenced project to
be used by the person ordering the concrete for this job.
Sincerely,
Texas Industries
Michael A. Caldarone, P.E.
Manager - Q.A. / Q.C.
Mix ~: 8204
Description: 470~ ADMIX/AEA
Strength: 3000 psi @ 28 Days
1 "CS
MACHINE PLACED
Maximum Coarse Aggregate: 1" - 1~4 CRUSHED STONE
Maximum Water/Cement Ratio: 5.90 gal/sack or 0.549 lbs/lb
Cement/Cementitious Content: 5.25 sacks (per cubic yard)
Maximum Placement Slump: 5.00 inches
Air Entraining Agent: ASTM C-260
Admixture: ASTM C-494 Type A or D
MATERIAL QUANTITIES PER 1.0 CUBIC YARD AT S.S.D
376 lbs. ASTM C 150 TYPE I CEMENT 94 lbs. ASTM C 618 FLY ASH
1840 lbs. 1" - ~4 CRUSHED STONE
1336 lbs. CONCRETE SAND
258 lbs. or 31.0 Gallons of Water
2.0 to 6.0 oz/cwt of ASTM C-494 Type A
Specified Air Content: 3.0% - 6.0%
Placement Slump: 4.00 + or - 1.00 inches
Mix $~: 8206
Description: 564~ ADMIX/AEA
Strength: 3000 psi @ 28 Days
1 "CS
HAND PLACED
Maximum Coarse Aggregate: 1" ~4 CRUSHED STONE
Maximum Water/Cement Ratio: 4.91 gal/sack or 0.457 lbs/lb
Cement/Cementitious Content: 6.31 sacks (per cubic yard)
Maximum Placement Slump: 5.00 inches
Air Entraining Agent: ASTM C-260
Admixture: ASTM C-494 Type A or D
MATERIAL QUANTITIES PER 1.0 CUBIC YARD AT S.S.D
451 lbs. ASTM C 150 TYPE I CEMENT
113 lbs. ASTM C 618 FLY ASH
1840 lbs. 1" ~4 CRUSHED STONE
1254 lbs. CONCRETE SAND
258 lbs. or 31.0 Gallons of Water
2.0 to 6.0 oz/cwt of ASTM C-494 Type A
Specified Air
Placement Slump: 4.00 + or - 1.00 inches
Mix #: 8274
Description: 6.00SK ADMIX/AEA
Strength: 4000 psi @ 28 Days
1 "CS
AS REQUIRED
Maximum Coarse Aggregate: 1" ~4 CRUSHED STONE
Maximum Water/Cement Ratio: 5.17 gal/Sack or 0.457 lbs/lb
Cement/Cementitious Content: 6.00 sacks (per cubic yard)
Maximum Placement Slump: 5.00 inches
Air Entraining Agent: ASTM C-260
Admixture: ASTM C-494 Type A or D
MATERIAL QUANTITIES PER 1.0 CUBIC YARD AT S.S.D
564 lbs. ASTM C 150 TYPE I CEMENT
1840 lbs. 1" - ~14 CRUSHED STONE
1273 lbs. CONCRETE SAND
258 lbs. or 31.0 Gallons of Water
2.0 to 4.0 oz/cwt of ASTM C-494 Type A
Specified Air Content: 3.0% 6.0%
Placement Slump: 4.00 + or 1.00 inches
PUMPING NOTES / RECOMMENDATIONS
2.
3.
4.
o
5" minimum diameter~lines with ~o reduction to smaller
lines.
Keep rubber hose ~absolute min~l~um length and plan pipe
with as few 90 degree a~es as possibl~.
Samples for slump and strength tests s~ould be taken
discharge end of hose for strength guarantee to be valid.
To prime pump lines, a minimum of 8.0 sack grout should be
used for lubrication. In the case of streng~t_~ concrete,
equivalent strength grout should be used if~ grout
remains in the placement.
Pump mixes are based on minimum cement content pumped at
ground level. As pump line increases in length or height
and/or layout configuration changes, additional cement may
be required to assure strength and pumpability at additional
cost to the contractor.
TXI cannot control, and is therefore not responsible for
excessive loss of entrained air content when loss occurs as
a result of boom configuration or free fall discharge from
hose. To ensure minimum air loss when pumping, maintain a
continuous flow of concrete through the entire length of
pipe and do not subject concrete to free fall.'
We are enclosing all available back up data for the referenced
mix design(s). If the strength information is not available, or
is insufficient, confirmation tests may have to be conducted by
your laboratory.
Date~ 02/11/98
CONCR~I'B DISIGN ~VALUATIOH
** St&tAstica Compiled From Indeponden~ L~orl~o~ Tee~ Spoct~n~ *,
mx ~or: 8204 S~reng~h: )000 pla · 28 Diyi
Test
Number
10/27/97
2 10/27/97
3 10/27/97
4 10/27/97
5 11/06/97
6 11/06/97
7 I1/07/97
8 11/10/97
9 11/10/97
10 11/19/97
11 11/19/97
12 11/21/97
13 11/25/97
14 12/01/97
15 12/01/97
16 12/10/97
17 12/10/97
18 12/10/97
19 12/10/97
20 12/10/97
21 12/11/97
22 12/11/97
23 12/11/97
24 12/11/97
25 12/11/97
26 12/19/97
27 12/30/97
28 12/31/97
29 01/02/98
30 01/02/98
Averages
Temperature
Plant (Fahrenheit)
Date Number Ambient Concrete
43 57 75
43 56 72
31 81
31 80
12 50 70
12 47 68
41 65 78
41 44 52
13 44 64
25 50 58
12 38 64
13 58 68
12 58 64
35 58 74
35 52 76
33 52 63
13 58 61
13 62 65
13 60 65
13 48 60
13 48 59
13 50 59
13 50 60
13 45 59
13 48 59
40 66 70
13 59 64
50 56
43
43 68
53 66
Placement Percent
Slump(in) of Air
4.75 4.2%
6.00 3.5%
5.5O 4.8%
5.25 5.0%
3.25 5.6%
3.50 4.6%
4.00 N/A
7.00 N/A
3.75 N/A
4.50 N/A
3.00 3.4%
4.00
5. O0
2.75 5.5%
2.00 5.6%
5.75 3.5%
5.00 4 0%
4.75 ] 2%
5.25 3 2%
5.50 3 2%
5.50 4 0%
5.75 ] 2%
5.75 4 0%
5.50 ] 4%
5.25 3 0%
4.00 N/A
5.50 N/A
4.75 5.4%
5.00 4.5%
5.25 4.6%
4.76 4.2%
......... 28 Day ........ Cumulative
PSI 1 PSI 2 PS! Avg Average
4080 4260 4170 41'10
3680 3720 3700 3935
4630 4560 4595 4155
5760 6120 5940 4601
5060 4770 4915 4664
5840 5780 5810 4855
5150 5080 5115 4892
4140 4070 4105 4794
5340 5190 5265 4846
4580 4690 4635 4825
4770 5220 4995 4840
44]0 4110 4270 479]
]730 ]950 3840 4720
4690 4690 4718
5480 5480 4768
4880 4750 4815 4771
5510 5400 5455 4811
5210 5140 5175 4832
5450 5310 5390 4861
4480 4560 4520 4844
4730 4870 4800 4841
4720 5010 4865 4843
5180 4800 4990 4849
5010 4920 4965 4854
5100 4860 4980 4859
5710 5630 5670 4890
3500 3520 3510 4839
4850 4760 4805 4838
4210 3980 4095 4812
4120 4200 4160 4790
Moving
Avg of 3 Range
180
40
4155 70
4745 360
5150 290
5555 60
5280 70
5010 70
4828 150
4668 110
4965 450
46]] 120
4368 220
4267
4670
4995 130
5250 110
5148 70
5337 140
5025 80
4900 140
4728 290
4885 ]80
4940 90
4978 240
5205 80
4720 20
4662 90
4137 230
4353 80
COMMENTARY OF STATISTICAL EVALUATION OF CONCRETE DESIGN RESULTS
Mix Num: 8204
Strength: 3000 psi ~ 28 Days
Paragraph 5.5 of ACI 318-89 provides that as data becomes
available during construction, the amount by which (F'cr) must
exceed the specified value of (F'c) may be reduced, provided:
(a) 30 or more test results are available and average of
test results exceeds that required by Section 5.3.2.1,
using a standard deviation calculated in accordance
with Section 5.3.1.1, or
(b) 15 to 29 test results are available and average of tes~
results exceeds that required by Section 5.3.2.1, using
a standard deviation calculated in accordance with
Section 5.3.1.2.
The required average compressive strength has been calculated
using a standard deviation calculated in accordance with
ACI 318-89 Section 5.3.1.1 or Section 5.3.1.2 and is the larger
value of these calculations:
F'cr = F'c + 1.34(SD)
= 3000 + 1.34( 614.0)
= 3823
F'cr = F'c + 2.33(SD) - 500
= 3000 + 2.33( 614.0) 500
= 3931
SUMMARY OF STATISTICAL ANALYSIS
28 Day Test Data
Number of Tests .......................... 30
Maximum Value ............................ 5940 psi
Minimum Value ............................ 3510 psi
Range .................................... 2430 psi
Average Strength ......................... 4790 psi
Standard Deviation ....................... 614 psi
Required Average Strength to satisfy
minimum probability conditions of
ACI 318-89 Section 5.3.2.1 ............... 3931 psi
Deei~n exceee beyond code requiremente... 859 psi
Dat~ 02/11/98
TEI[A~ INDUSTRIES
CONCRETE DESIGN ~V~~LUATZOH
*° StsttS~lCS Compilsd From Indapsndant Laboratory
Hlx Numbor~ 8206
Strsngth~ 3000 psi · 28 Days
Temperature
Test Plant (Fahrenheit) Placement Percent
Number Date Humber Ambient Concrete Slumpiin) of Air
1 12/01/97 24 68 0.50 ].6%
2 12/01/97 24 65 3.00 4.5%
3 12/02/97 12 55 62 3.50 5.0%
4 12/05/97 25 45 60 3.50 5.0%
5 12/05/97 24 55 2.50 4.2%
6 12/05/97 24 ].50 6.0%
7 12/05/97 24 64 3.00 4.5%
8 12/05/97 24 65 2.50 4.2%
9 12/06/97 24 62 4.00 ].9%
10 12/06/97 24 60 3.90 ].5%
11 12/06/97 24 64 3,50 3.8%
12 12/06/97 24 66 5,00 4.0%
13 12/06/97 24 68 7.50 4.0%
14 12/09/97 35 60 68 4.25 4.]%
15 12/10/97 24 59 5.00 7.0%
16 12/10/97 24 68 2.50
17 12/10/97 24 67 3.00 ].4%
18 12/11/97 25 37 51 3.50 7.0%
19 12/11/97 24 58 3,50 3,4%
20 12/11/97 24 59 3.00 3.2%
21 12/11/97 24 61 4.50 ],4%
22 12/12/97 50 38 66 4.75 5.1%
23 12/12/97 50 45 65 4.50
24 12/15/97 25 58 54 5.00 6,2%
25 12/16/97 25 62 66 3.75 5.0%
26 12/16/97 25 58 63 4.00 5.1%
27 12/18/97 25 65 64 4.00 5.1%
28 12/18/97 25 58 56 3.50
29 12/19/97 25 64 66 3.75 5.5%
30 12/19/97 25 60 64 4.00 6.0%
*** Averages *** 54 6] 3.75 4,7%
......... 28 Day ........ Cumulative
PSI 1 PSI 2 PSI Avg Average
7520 7640 7580 7580
6550 6600 6575 7078
5640 5660 5650 6602
5300 5420 5360 6291
5270 6190 5730 6179
6190 6190 6190 6181
6190 6800 6495 6226
6190 7370 6780 6295
6440 6450 6445 6312
6750 6720 6735 6354
7230 7320 7275 6438
6600 6690 6645 6455
6560 6590 6575 6464
5570 5840 5705 6410
4990 4860 4925 6311
6830 6900 6865 6346
7000 6940 6970 6382
4740 4710 4725 6290
6680 6830 6755 6315
7070 7460 7265 6362
7390 7320 7355 6410
6160 6380 6270 6403
5990 6100 6045 6]88
4600 4720 4660 6316
5390 5410 5400 6279
5210 5270 5240 6239
5100 5210 5155 6199
4690 4830 4750 6147
5370 5]60 5365 6120
5120 5160 5140 6088
Moving
Avg of 3 Range
120
50
6602 20
5862 120
5580 920
5760 0
6138 610
6488 1180
6573 10
6653 30
6618 90
6665 90
6832 30
6308 270
5735 130
5832 70
6253 60
6187 30
6150 150
6248 390
7125 70
6963 220
6557 110
5658 120
5368 20
5100 60
5265 110
5048 120
5090 10
5085 40
COMMENTARY OF STATISTICAL EVALUATION OF CONCRETE DESIGN RESULTS
Mix Num: 8206
Strength: 3000 psi ~ 28 Days
Paragraph 5.5 of ACI 318-89 provides that as data becomes
available during construction, the amount by which (F'cr) must
exceed the specified value of (F'c) may be reduced, provided:
(a) 30 or more test results are available and average of
test results exceeds that required by Section 5.3.2.1,
using a standard deviation calculated in accordance
with Section 5.3.1.1, or
(b) 15 to 29 test results are available and average of test
results exceeds that required by Section 5.3.2.1, using
a standard deviation calculated in accordance with
Section 5.3.1.2.
The required average compressive strength has been calculated
using a standard deviation calculated in accordance with
ACI 318-89 Section 5.3.1.1 or Section 5.3.1.2 and is the larger
value of these calculations:
F'cr = F'c + 1.34(SD)
= 3000 + 1.34( 870.9)
= 4167
F'cr = F'c + 2.33(SD) - 500
= 3000 + 2.33( 870.9) - 500
= 4529
SUMMARY OF STATISTICAL ANALYSIS
28 Day Test Data
Number of Tests .......................... 30
Maximum Value ............................ 7580 psi
Minimum Value ............................ 4660 psi
Range .................................... 2920 psi
Average Strength ......................... 6088 psi
Standard Deviation ....................... 871 psi
Required Average Strength to satisfy
minimum probability conditions of
ACI 318-89 Section 5.3.2.1 ............... 4529 psi
Design excess beyond code requirements... 1559 psi
TIXAS ZNDUSTRIIS
COHCRrT[ D~SI(I~ IFVALUATION
Nix l'/umber~ 8274
Strength~ 4000 pal · 28 Daya
Test
Number Date
1 11/11/97
2 11/17/97
3 11/20/97
4 11/20/97
5 11/20/97
6 11/20/97
7 11/20/97
8 11121197
9 11/21/97
10 11/25/97
11 12/05/97
12 12/05/97
13 12/05/97
14 12/05/97
15 12/05/97
16 12/09/97
17 12/10/97
18 12/12/97
19 12/12/97
20 12/12/97
21 12/15/97
22 12/17/97
2] 12/17/97
24 12/17/97
25 12/17/97
26 12/18/97
27 12/19/97
28 12/29/97
29 12/30/97
30 12/30/97
Tempera:u£e
Plant {Fahrenheit} Placement
Number Ambient Concrete Slump(in)
43 64 68 6.00
43 54 68 4.50
40 44 66 4.75
18 52 70 4.50
18 64 2.00
18 63 3.50
13 40 7] 4.50
43 56 72 4.00
18 63 70 5.25
43 65 72 5.50
46 65 70 5.00
46 50 59 4.75
46 ]8 59 4.75
46 32 49 4.50
46 30 47 4,75
43 65 68 5.50
42 40 61 4.25
46 37 53 5.00
46 37 5] 5.25
46 37 54 5.50
43 45 60 6.00
46 37 60 4.25
46 38 61 4.00
46 ]9 60 4.50
43 62 68 5.00
41 60 71 4.25
43 65 72 4,50
4] 50 49 3,50
38 52 5.00
38 55 6.00
49 62
Percent ......... 28 Day ........ Cumulative
of Air PSI I PSI 2 PSI Avg Average
N/A 4690 4770 47]0 47]0
N/A 5020 49]0 4975 485]
N/A 5050 5170 5110 49]8
N/A 5550 5550 5550 5091
4.3% 6170 6260 6215 5316
4.0% 5380 5490 5435 5336
5.8% 5020 5020 5020 5291
N/A 6130 6310 6220 5407
N/A 4810 4560 4685 5327
N/A 4500 4440 4470 5241
1.3% 5360 5490 5425 5258
3.2% 4780 4630 4705 5212
3.5% 5490 5360 5425 5228
3.3% 5780 5820 5800 5269
3.2% 5330 5490 5410 5278
N/A 4750 4660 4705 5243
N/A 5120 4950 5035 5230
5.4% 6000 6190 6095 5278
4.5% 6170 6070 6120 532]
5.1% 5990 6130 6060 5360
N/A 4110 4230 4170 5303
3.4% 6010 6170 6090 53]9
3.2% 5940 5780 5860 5361
3,4% 5810 5990 5900 5384
N/A 5100 5160 5130 5374
N/A 5290 5130 5210 5367
N/A 5760 5830 5795 5383
r{/A 5]40 4950 5145 5]75
4.7% 5340 5460 5400 5376
].2% 4470 4460 4465 5345
4.69 4.0%
Moving
Avg of ] Range
80
90
4938 120
S212 0
5625 90
5733 110
5557 0
5558 180
5308 250
5125 60
4860 130
4867 150
5185 130
5310 40
5545 160
5]05 90
5050 170
5278 190
5750 100
6092 140
5450 120
5440 160
5373 160
5950 lBO
56]0 60
5413 160
5378 70
5383 390
5447 120
5003 10
COMMENTARY OF STATISTICAL EVALUATION OF CONCRETE DESIGN RESULTD
Mix Num: 8274
Strength: 4000 psi ~ 28 Days
Paragraph 5.5 of ACI 318-89 provides that as data becomes
available during construction, the amount by which (F'cr) must
exceed the specified value of (F'c) may be reduced, provided:
(a) 30 or more test results are available and average of
test results exceeds that required by Section 5.3.2.1,
using a standard deviation calculated in accordance
with Section 5.3.1.1, or
(b) 15 to 29 test results are available and average of test
results exceeds that required by Section 5.3.2.1, using
a standard deviation calculated in accordance with
Section 5.3.1.2.
The required average compressive strength has been calculated
using a standard deviation calculated in accordance with
ACI 318-89 Section 5.3.1.1 or Section 5.3.1.2 and is the larger
value of these calculations:
F' cr = F' c + 1. 34 (SD)
= 4000 + 1.34 ( 583.0)
= 4781
F'cr = F'c + 2.33 (SD) - 500
= 4000 + 2.33 ( 583.0) 500
= 4858
SUMMARY OF~ISTICAL ANALYSIS
28 DafTest Data
Number of Tests .......................... 30
Maximum Value ............................ 6220 psi
Minimum Value ............................ 4170 psi
Range .................................... 2050 psi
Average Strength ......................... 5345 psi
Standard Deviation ....................... 583 psi
Required Average Streng~ to satisfy
minimum probability ¢on~ion~ of
ACI 318-89 Section 5.3.2.1 ............... 4858 psi
Design excess beyond code requirements... 487 psi
MIDLOTHIAN CEMENT PLANT * 2,15 Ward Road · Midlothian, Texas 76065 · www. lxi.com
SPECIFICATIONS
Porlland Comonl
Typo 1/11 (Low Alkali)
A.S.T.M. C150-97'
Bin Number
Car Numi)or
Tons
Date of SamDIin.0 December t 997 Monthly Avo~a.0e
IASTM I TEST
SPECIFICATION RESULTS
CHEMICAL REQUIREMENTS
Silica Oxide, Minimum Porconl 20.0 20.7
Alumina Oxide, Maximum Porcon! 6.0 4.3
Iron Oxide, Maximum Porconl 6.0 3.9
Magnesia Oxide, Maximum Percent 6.0 i .2
SO3 (C3A less than 8% ), Maximum Percent ' 34
Loss on Ignilion, Maximum Porconl 3.0 1.0
Insoluble residue, Maximum Porconl -- 0.75 0.22
Tricalcium Alummale, Maximum Pefcenl 8 5
OPTIONAL CHEMICAL FIEQUIFtEMENTS
Tolal Alkalies, Max. qb (Na20 equiv.) J 0.60 [. b.32
PHYSICAL REQUlFIEMENTS
Specific sur lace, Blaine Minimum (M' 2/Kg) 280 334
Gillmoro, Inilial Set, Minimum (Minutes) 60 163
Gilhnoro, Final Sol, Maximum (Minules) G00 287
Vical, IMinirnum (Minutes) 45
ilnilial. Sol JMaximum (Minutes) 375 105
!A~r Conlenl, Volume, Maximum Percent 12 G
:Auloclavo Expansion, lvlaximum Percenl 0.80 0
3 Day Minimum Compressive Slren01h' MPa (i)s0 12.0 (1740) 23.6 (3421)
7 Day Minimum Compressive Sl~'ongth, MPa (Ps0 19.0 (2760) 30.8 (4459)
qT^T~ A~ Tr2v^o --
ELLIS COUNTY
J.R. Owens , being duly sworn deposes and says; II~al he is Clliel Chemisl of
TXI, Midlolhian Cement Plant, who I)mpared tho above ropoJl of lesls and
Ihal tho same is Irue and co~[ecl.
"Gee ASTM C 150 'l';d)h; 1, Foolnole
Gifford-Hill & Company
FM 1735 · P.O. BOX 278 ,, CASON. TEXAS 75636
GIFFORD.HILL
FLY ASH ANALYSIS
MATERIAL: Class C Fly Ash
SAMPLED BY: Gilford Hill
SOURCE: #750 CASON FLYASH
DATE: 11/25/1997
SPECIFICATION: ASTM C-618
TEST PRODCEDURE: ASTM C-311
SAMPLE NUMBER:
DATE SAMPLED:
PHYSICAL TEST
Specific Gravity
Variation From Avg.(%)
Retained on No. 325(%)
Variation, %Points from Avg.
Water Requirement(%)
Pozz Index, % Control
Autoclave Soundness(%)
Moisture Content(%)
Loss on Ignition
CHEMICAL TEST *
Silicon Dioxide, SIO2(%)
Aluminum Oxide, A1203(%)
Iron Oxide, Fe203(%)
Total: SiO2;A12o3;Fe203 %
Sulphur Trioxide, SO3(%)
Magnesium Oxide, MgO(%)
Calcium Oxide, CaO(%)
Sodium Oxide Eqv, Na20(%)
Available Alkalai as Na20(%)
386544 SPECS.
09/03/1997
2.78 ...
.15 5.0 (Max.)
20.6 34.0 (Max.)
.4 5.0 (Max.)
96.7 105.0 (Max.)
92.2 75.0 (Min.)
+.116 +0.8 (Max.)
.05 3.0 (Max.)
.49 6.0 (Max.)
31.80 ...
18.58 ...
5.15 ...
55.53 50.0 (Min.)
4.01 5.0 (Max.)
6.73 ...
29.33 ...
2.18 ...
.87
Jack Cop~ .
Quality Control