Loading...
Gibbs Sta DCEC-LR 940422 reed engineering GEOTECHNICAL CONSULTANTS CONCRETE COMPRESSION TEST REPORT 2 . REPORTNO.: JOBNO.: 1691 1 DATECAST: 04/22/94 Gibbs Station Retaining Wall 3000 PSI PROJECT: SPECIFICATION: Pier - #3 11/11 yds LOCATION: OUANTITY REPRESENTED: ARCHITECT/ENGINEER: SAMPLED BY: R. Thomib s on CONTRACTOR: aY ORDER OF: C1 ient 05/20/94 REPORTED TO: Craig Olden, Inc. DATE: 04/29/94 ORDER NUMBER: (6 X 12 INCH) NOMINAL CYLINDER SIZE: AREA-28.26 SQ. IN. LABORATORY NUMBER F, ELDNUMBER~ GS042201 GS042202 GS042203 GS042204 MAXIMUM LOAD. LBS: 109, 000 112, 000 140, 500 140, 000 AGE WHEN TESTED, DAYS: 7 7 2 8 2 8 3860 3960 4970 4950 COMPRESSIVE STRENGTH, PSI: 3910 4960 AVERAGE STRENGTH, PSI: TYPE BREAK: CONICAL {U.N.O.) REMARKS: Does comply with Specification METHOD OF CURING: FIELD DAYS. LABORATORY FROM TRANSPORTED BY 1 04/23/94 Reed TEMPERATURE: AMBIENT °F MIX "F, AIR CONTENT %, SLUMP INCHES 78 82 5.50 TIME OF SAMPLE; 05 : 05 ~PM, PICK-UP CHARGE: ~ NO SOURCE OF CONCRETE: La t t/more M,X CODE: 18 TICKET NO.: 3002090 FINE AGGREGATE: UNIT WEIGHT PCF COARSE AGGREGATE: WATER: YIELD CFICY CEMENT: FLY ASH: ADMIXTURE(S): DISTRIBUTION: (1) Craig Olden, Inc./Mr. Craig Olden ~.%.. ~ (1) City of Coppell/Mr. Larry Davis SIGNED TEST METHODS: ASTM C 31. C 39, C 143, C 173, C 192, C 231, OR C 1064 PAGE 1 OF1 2424 STUTZ DRIVE · SUITE400 · DALLAS, TEXAS75235 · 214/350-5600 · (FAX) 214/350-0019