Loading...
Gibbs Station 1-LR 930327ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 (214) 620-8911 REPOI OF FIELD COMPACTION TESTS TESTED FOR: HEATH & KNIGHT PROPERTIES, INC. DATE: DALLAS, TEXAS 03/27/93 PROJECT: GIBBS STATION LAKES OF COPPELL COPPELL, TEXAS OUR REPORT NO. 92020-177 TEST DATA: T[$T DATE~ KLIV. lOlL lO OPTI#UN MAXIMUM LAI IN PLACC IN PLACIE NO, lriEPTH MICC NOIITUIi lOT Ol#llTT MOIITUNI ONY DBNIITY FIN CCNT COMM~rNTe ........ 1~ PCI qb PCP COMPACTION 861 03/27 FG-1 17 22.3 95.9 23.6 92 96 862 03/27 FG-1 17 22.3 95.9 23.9 94 98 1-A 863 03/27 FG-1 8 26.8 88.0 27.2 86 98 8(>4 03/27 FG-i 8 26.8 88.0 27.4 86 97 i-A 8(>5 03/27 FG- .5 8 26.8 88.0 26.9 8(> 97 1-A 866 03/27 FG- . $ 8 26 . 8 88 . 0 27 . 7 84 95 1-A 867 03/27 FG-. 5 8 2(>. 8 88.0 28.2 85 96 1-A TEST LOCATION: PAD FILL 861 BLOCK D LOT 36 862 BLOCK D LOT 34 8(>3 BLOCK D LOT 32 8(>4 8LOCK D LOT 30 865 BLOCK D LOT 28 8(>(> 8LOCK D LOT 26 8(>7 BLOCK D LOT 27 1. FILL 2. NATURAL SUBGRADE 3. LIME STABILIZED 4. CEMENT TREATED · A. TEST RESULTS COMPLY WITH SPECIFICATIONS B. COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS C. MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS D. RETEST