Gibbs Station 1-LR 921130 (2)ALPHA TESTING, INC. 2209 Wisconsin St. Suite 100 Dallas, Texas 75229 (214) 620-8911 REPORT OF CONCRETE COMPRESSION TEST TESTED FOR: HEATH & KNIGHT PROPERTIES, INC. DATE: DALLAS, TEXAS 11/30/92 PROJECT: GIBBS STATION LAKES OF COPPELL MacARTHUR BLVD. COPPELL, TEXAS VILLAGE PKWY. OUR REPORT NO. 92020-141 LOCATION OF CONCRETE PLACEMENT PAVING 11/30/92 DATE PLACED 1:00 TIME 2' SLUMP AIR CONTENT AIR TEMPERATURE 52 CONCRETE TEMPERATURE 54 DATE RECEIVED 12/O3/92 FIELD DATA SUBMITTED BY DM MIX DATA SUBMITTED aY LHL FIELD DATA ALLEY F-1 O STA. 0+10 ON SITE PLANT DELIVER TICKET NO. MIX PROPORTIONS (SSD) CEMENT N/A WATER N/A FINE AGGREGATE COARSE AGGREGATE ADMIXTURE COMPRESSION TEST RESULTS (NOMINAL CYLINDER SIZE 6" X 12") Lab. Customer Type Data A~e Coml~'mve No. No. Curing Te~ted Day~ StrMt~h, Psi 139 92020 LAB 12/07/92 7 3750 140 92020 LAB 12/28/92 28 141 92020 LAB 12/28/92 28 142 92020 LA8 HOLD I Spec,f,ca~:,ons 28 3600 REMARKS [~"'~Cylinders made by ALPHA representative. [] Cylinders made by Architect's or Contractor's representative. [~linders picked up by ALPHA laboratory. [] Compression test results comply with applicable specifications. with applicable specifications. TYPE OF FRACTURE, IF OTHER THAN CONICAL Tlly Submitted TESTING, INC.