Gibbs Station 1-LR 921012 (2)ALPHA TESTING, INC· 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 (214) 620-8911 REPO OF FIELD COMPACTION TESTS TESTED FOR: J W L COMPANY C/O UNZICKER, & ASSOCIATES DALLAS, TEXAS SCHNURBUSH, DATE: 10/12/92 PROJECT: LAKEWOOD ESTATES COPPELL, TEXAS OUR REPORT NO. 92159-62 TEST DATA: [ [~EV'EIOILID OPTIMU##AEI#UMLAIINPLACEINPLACE TEST DAT[ MOIITUNE ONY OENIITY MOIITUIE DBY BENIITY PER CENT COMMENT· NO ~)EPTH ~1 NUMBER,. ~ PCP ~ PCP COMPACTION 580 10/12 FG-.5 6 18.8 108.0 20.8 105 97 1-A 581 10/12 FG 6 18.8 108.0 21.8 104 96 1-A 582 10/12 FG 6 18.8 108.0 20.7 105 97 1-A 583 10/12 FG 6 18.8 108.0 20.4 105 97 1-A S84 10/12 FG 6 i8.8 108.0 18.8 106 98 i-A 585 10/12 FG 6 18.8 108.0 17.8 108 100 1-A 586 10/12 FG 6 18.8 108.0 18.1 107 99 i-A TEST LOCATION: FILL 580 BLOCK E LOT 10 581 8LOCK E LOT 7 582 BLOCK E LOT 9 583 8LOCK E LOT 12 584 8LOCK E LOT 14 585 8LOCK D LOT 1 586 BLOCK D LOT 3 1. FILL 2. NATURAL SUBGRADE 3. LIME STABILIZED 4. A. TEST RESULTS COMPLY WITH SPECIFICATIONS B. COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS C. MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS D. RETEST