Loading...
Gibbs Station 1-LR 920929ALPHA TESTING, INC. 2209 Wisconsin St. Suite 100 Dallas, Texas 75229 (214) 620-8911 REPORT OF CONCRETE COMPRESSION TEST TESTED FOR: HEATH & KNIGHT PROPERTIES, INC. DATE: DALLAS, TEXAS 09/29/92 PROJECT: GIBBS STATION LAKES OF COPPELL MacARTHUR BLVD. COPPELL, TEXAS VILLAGE PKWY. OUR REPORT NO. 92020-70 FIELD DATA LOCATION OF CONCRETE PLACEMENT LINE A, MANHOLE STA. 0+00 09/29/92 PLANT DATE PLACED. 2 '- 30 DELIVER TICKET NO. TIME N/A MIX PROPORTIONS (SSD) N/A SLUMP AIR CONTENT N/A CEMENT N/A AIR TEMPERATURE N/A WATER N/A CONCRETE TEMPERATURE N/A FINE AGGREGATE N/A DATE RECEIVED 10/02/92 COARSE AGGREGATE N/A FIELD DATA SUBMITTED BY CLIENT MADE ADMIXTURE N/A MIX DATA SUBMIT'TED BY REDI-MIX COMPRESSION TEST RESULTS (NOMINAL CYLINDER SIZE 6" X 12") i D?yy~ Coml~e~ive Lab. Cultomer Type Date No. No. Curir~ Te~ted St~tgth, Psi - 20 92020 LAB 10/06/92 7 4540 21 92020 LAB 10/27/92 28 5510 22 92020 LAB 10/27/92 28 5620 Spec,f ,cat,ores 28 4000 REMARKS [] Cylinders made by ALPHA representative. [] Cylinders made by Amhitact's or Contractor's representative. [~Cylinders picked up by ALPHA laboratory. [~Compresston test results comply with applicable specifications. [] Compression test results do not comply with applicable specifications. ~ CLTENT MADE TYPE OF FRACTURE, IF OTHER THAN CONICAL