Gibbs Station 1-LR 920911ALPHA TESTING, INC.
2209 Wisconsin St., Suite 100
Dallas, Texas 75229
(214) 620-8911
REPORT OF FIELD
COMPACTION TESTS
TESTEOFOR: HEATH & KNIGHT PROPERTIES, INC. DATE:
DALLAS, TEXAS
09/11/92
PROJECT:
GIBBS STATION
LAKES OF COPPELL
COPPELL, TEXAS
OUR REPORT NO.
92020-43
TEST DATA:
TEST DATE [~ ~LEV. lOlL IO OPTIMUM MAXIMUM LAI IN PLACE IN PLACE
~ MOIiTUNi ONY OENIITY MOIITUEI BEY OINIITY PiN CENT COMMENT·
NO, ~, .,, _ NUMBER_ , ~ PCP ~ PCP COMPACTION
369 09/11 FG-4 7 15.5 109.4 19.5 103 95
370 09/11 FG-4 7 15.5 109.4 19.2 104 95 i-A
371 09/11 FG-4 2 18.2 103.8 19.5 102 98 i-A
i372 09/11 FG-2 2 18.2 103.8 20.8 102 98 1-A
373 09/11 FG-2 7 15.5 109.4 16.2 106 97 1-A
374 09/11 FG ? 15.5 109.4 18.9 105 96 1-A
375 09/ii FG 7 15.5 109.4 15.7 106 97 1-A
TEST LOCATION: UTILITY TESTS
369 SANITARY SEWER LINE D LATERAL TO BLOCK G LOT 1S
370 SANITARY SEWER LINE D LATERAL TO 8LOCK G LOT i3
371 SANITARY SEWER LINE D LATERAL TO 8LOCK G LOT ii
372 SANITARY SEWER LINE O LATERAL TO BLOCK G LOT 12
373 SANITARY SEWER LINE D LATERAL TO BLOCK G LOT 14
374 SANITARY SEWER LINE D LATERAL TO 8LOCK G LOT 12
375 SANITARY SEWER LINE D LATERAL TO 8LOCK G LOT 14
1. FILL
2. NATURAL SUBGRADE
3. LIME STABILIZED
4.
A. TEST RESULTS COMPLY WITH SPECIFICATIONS
B. COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS
C. MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS
D. RETEST