Gibbs Station 1-LR 920831ALPHA TESTING, INC.
2209 Wisconsin St., Suite 100
Dallas, Texas 75229
(214) 620-8911
DAILY FIELD REPORT
TESTED FOR
HEATH & KNIGHT PROPERTIES, INC. DATE
DALLAS, TEXAS
08/31/92
PROJECT
GIBBS STATION
LAKES OF COPPELL
COPPELL, TEXAS
OUR REPORT NO. 92020-30
WEATHER: PARTLY CLOUDY
TEMPERATURE RANGE: 80
ALPHA Representative: D. M.
DATE:
TO: 91
08/31/92
THE ALPHA TECHNICIAN TRAVELED TO THE PROJECT SITE AS REQUESTED BY THE
CLIENT TO PERFORM FIELD DENSITY TESTING.
A TOTAL OF FOUR FIELD DENSITY TESTS WERE PERFORMED ON FILL SOILS FOR THE
BUILDING PAD AREA. SEE ATTACHED REPORT OF FIELD COMPACTION TESTS.
THE TECHNICIAN ALSO 08SERVED THE PROOFROLLING OF BUILDING PADS NUMBERED
NINETEEN AND EIGHTEEN OF 8LOCK C, AND LOT FIFTEEN OF BLOCK E. THE AREA HAD
BEEN PROOFROLLED ON 08/22/92, HOWEVER; RECENT RAINS HAD LEFT STANDING WATER
IN THIS AREA. THE CONTRACTOR DRAINED THE AREA, ALLOWED IT TO DRY, AND RE-
PROOFROLLED THE EXCAVATED AREA. A MOTOR GRADER WAS USED TO PERFORM
PROOFROLLING. NO SOFT, WEAK, OR WET AREAS WERE 08SERVED.
THE GREGORY REPRESENTATIVE WAS INFORMED OF TEST RESULTS WHICH APPEARED TO
COMPLY WITH PROJECT SPECIFICATIONS.
TECHNICIAN RETURNED TO THE LABORATORY UPON COMPLETION OF SCHEDULED TESTING.