Gibbs Station 1-LR 920822ALPHA TESTING, INC.
2209 Wisconsin St., Suite 100
Dallas, Texas 75229
(214) 620-8911
DAILY FIELD REPORT
TESTED FOR
HEATH & KNIGHT PROPERTIES, INC. DATE
DALLAS, TEXAS
08/22/92
PROJECT
GIBBS STATION
LAKES OF COPPELL
COPPELL, TEXAS
OUR REPORT NO. 92020-26
WEATHER: CLEAR
TEMPERATURE RANGE: 70
ALPHA Representative: D. M.
DATE: 08/22/92
TO: 90
THE ALPHA TECHNICIAN TRAVELED TO THE PROJECT SITE AS REQUESTED BY THE
CLIENT TO PERFORM FIELD DENSITY TESTING.
AFTER EXCAVATION, THE TECHNICIAN OBSERVED THE PROOFROLLING OF LOTS i9, AND
i8 OF 8LOCK C, AND BLOCK E LOT 1S. THE AREA WAS SCARIFIED, RECOMPACTED,
AND TESTED PRIOR TO PROOFROLLING. PROOFROLLING WAS ACCOMPLISHED USING A
MOTOR GRADER. NO SOFT OR WEAK AREAS WERE 08SERVED.
A TOTAL OF SEVENTEEN FIELD DENSITY TESTS WERE PERFORMED ON FILL SOILS FOR
THE BUILDING PADS. SEE ATTACHED REPORT OF FIELD COMPACTION TESTS.
THE GREGORY REPRESENTATIVE WAS INFORMED OF TEST RESULTS WHICH APPEARED TO
COMPLY WITH PROJECT SPECIFICATIONS.
TECHNICIAN RETURNED TO THE LABORATORY UPON COMPLETION OF SCHEDULED TESTING.