Gibbs Station 1-LR 920622 (2)ALPHA TESTING, INC.
2209 Wisconsin St., Suite 100
Dallas, Texas 75229
(214) 620-8911
OF FIELD
COMPACTION TESTS
TESTED FOR: HEATH & KNIGHT PROPERTIES, INC. DATE: 06/22/92
DALLAS, TEXAS
PROJECT: GIBBS STATION OUR#E~RT~O. 92020--11A
Lib(ES OF COPPELL
HacARTHUR BLVD. · VILLAGE PKNY.
COPPELL, TEXAS
TESTDATA:
TEST DATE -- MOIiTUiI ORY OINIITY #OIITURI DRY DKNIITY PEru CmNT COMMENT·
NO. ~EPTH -~--~ I _ ~ PGF ~ PCF COMPACTION
68. 06/22 SG 4 12.8 117.2 8.2 115 90
69 06/22 SG 4 12.8 117.2 8.0 112 96
70 06/22 SG 2 18.2 103.8 7.6 97 96 il-C
71 06/22 SG 2 18.2 103.8 22.0 99 94
72 06/22 SG 3 22.6 92.2 23.0 89 95 I-A
73 06/22 SG 3 22.6 92.2 28.8 90 97
74 06/22 SG 3 22.6 92.2 28.7 90 97
TEST LOCATION:
68 BLOCK B LOT 10
69 BLOCK B LOT 13
70 BLOCK B LOT 16
71 BLOCK C LOT 7
72 BLOCK C LOT 10
73 BLOCK C LOT
74 BLOCK C LOT 16
*SUBGRADE TEST
1. FILL
2. NATURAL SUBGRADE
3. LIME STABILIZED
4.
IN GRANULAR MATERIAL, MOISTURE CONTENT NOT CRITICAL.
· A. TEST RESULTS COMPLY WITH SPECIFICATIONS R~pecI~JIr~'~, ~,
B. COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS ~_/"~/
C. MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS
D. RETEST