Gibbs Station 1-LR 920622 (4)ALPHA TESTING, IN'C.
2209 Wisconsin St., Suite 100
Dallas, Texas 75229
REPOi. n' OF FIELD
COMPACTION TESTS
(214) 620-8911
II
TESTED FOR: HEATH & KNIGHT PROPERTIES, INC. DATE:
DALLAS, TEXAS
06/22/92
PROJECT: GIBBS STATION OURRE~RTNO.
LAKES OF COPPELL
M&cARTHUR BLVD. I VILLAGE PKWY.
COPPELL, TEXAS
TEST DATA:
92020-11
(REVISED 7/8/92)
T[$T DAT£ ELiV. 1OIL lO OPTIMUM MAXIMUM LAB IN PLACI IN PLA¢I
NO, NUMBER MOIITUBE DRY OINIITY MOIITUBI OBY OBNIITY PER Ci~ COMMENTe
~ PCP ~ PCP COMPACTION
61 06/22 FG 6 13.4 113.9 13.4 111 98 1-A
62 06/22 FG 6 13.4 113.9 13.9 113 99
63 06/22 FG 7 15.S 109.4 18.1 107 98
64 06/22 FG 7 15.5 109.4 18.4 107 98 1-A
65 06/22 SG 4 12.B 117.2 12.8 113 96
66 06/22 SG 4 12.B 117.2 14.4 112 96 1-A
67 06/22 SG 4 12.8 117.2 8.1 114 97 1-A
TEST LOCATION:
61 BLOCK F LOT 29 ~*
62 BLOCK F LOT 26 ,
63 BLOCK F LOT 23 *-
64 BLOCK F LOT 20 ~
65 BLOCK B LOT I PHASE II
66 BLOCK B LOT 4 PBASE II
67 BLOCK B LOT 7 PHASE II
*SUBGRADE TEST
1. FILL
2. NATURAL SUBGRADE
3. LIME STABILIZED
4.
IN GRANULAR MATERIAL, MOISTURE CONTENT NOT CRITICAL.
A. TEST RESULTS COMPLY WITH SPECIFICATIONS
B. COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS
C. MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS
D. RETEST