Loading...
Gibbs Station 1-LR 920622 (5)ALPHA TESTING, IFiC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 (214) 620-8911 REINStall' OF FIELD COMPACTION TESTS TESTED FOR: HEATH & KNTGHT PROPERTIES, INC. DATE: 06/22/92 DALLAS, TEXAS PROJECT: GIBBS STATION OUR REPORT NO. 92020-11A LAKES OF COPPELL (REV[STuD 7/8/92) MacARTHUR BLVD. t VILLAGE PKWY. COPPELL, TEXAS TEST DATA: TEST DATE v, OPTIMUM MAXIMUM LAI IN Fi. ACE IN FI,ACE MOIITUIlE Oily OENIITY MOIITUIlE DRY OiilllTY Plil CEIlT COMMENT· NO. ~ ~)EPT. ~-I ~ PC~' qb I'CI~' COMPACTION ~6B. 06/22 SG 4 12.8 117.2 B.2 115 98 1-A ~r 6':) 06/22 SG 4 1:2.8 117.2 8.0 112 96 1-A 70 06/22 SG 2 18.2 103 .B 7.6 97 96 1-C 71 06/22 SG :2 18.2 103 .B 22.0 99 94 1-A 72 06/22 SG 3 22.6 92.2 23.0 89 95 1-A 73 06/22 5G 3 22.6 92.2 28.8 90 97 1-A 74 06/22 SG 3 22.6 92.2 28.7 90 97 1-A TEST LOCATION: 68 BLOCK B LOT 10 PHASE II 69 BLOCK B LOT 13 PHASE II 70 BLOCK B LOT 16 PHASE II 71 BLOCK C LOT 7 -~ __7_2 BLOCK C LOT 10 ~ 73 BLOCK C LOT 13 ~ 74 BLOCK C LOT 16 *SUBGRADE TEST 1. FILL 2. NATURAL SUBGRADE 3. LIME STABILIZED 4. IN GRANULAR MATERIAL, MOISTURE CONTENT NOT CRITICAL. · A. TEST RESULTS COMPLY WITH SPECIFICATIONS R~.j~3*~, ~-~--~ B. COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS C. MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS D. RETEST