Gibbs Station 1-LR 920618ALPHA TESTING, INC.
2209 wisconsin St., Suite 100
Dallas, Texas 75229
(214) 620-8911
REPO OF FIELD
COMPACTION TESTS
TESTED FOR: HEATH & KNIGHT PROPERTIES, INC. DAT~:
DALLAS, TEXAS
06/18/92
PROJECT:
GIBBS STATION
LAKES OF COPPELL
COPPELL, TEXAS
OUR RF. IN~T NO.
92020-10
(REVISED 7/8/92)
TEST DATA:
T[ST DATE ~1.0iLiD I OP?IMU# ~AXlMU#~I 'NP~Cl IN'~C!
NO. NUMBER MOII?UBI BY ::~l?V' MmffUBl NY
· · PCP QOMPACTION
S4 0C/18 FG $ 26.8 88.0 29.$
55 06/18 FG 8 2b.6 88.0 30.0 83 94 1-A
5,7 06/'18 FG S 26.8 88.0 29.2 84 95 1-A
58 06/18 FG 8 26.8 88.0 26.8 86 97 1-A
59 06/18 FG $ 26.8 88.0 26.9 86 97
60 O&,/I8 FG 8 26.8 88.0 28.7 86 98 1-A
TEST LOCATION: ~ OT ?ILL
56 8LOCK C LOT £ !0' C. & i. 5' N. FROM $.W. CORNER OF PAD
~-~ BLOCK C LOT 5 iO'--~-- & 1%-,' ,N. F'ROH S.W. CORNER OF PAD
r:? BLOCK r- L°T ~-- iC ~ . F~Or4 S.~ CORNER OF PAD
.~:,, .~ t23- ' E- & 1~ :' ;~ F
5~ E.L,DC~q C LOT ~0" LO' Z. :~, i5' N. ~'F~OH ~..N. CORNER OF PAD
60 SLOCK C LOT i7 iO' E. & 15' N. FROM 5,,W. CORNER OF PAD
1. FILL
2. NATURAL SUBGRADE
3. LIME STABILIZED
4.
A. TEST RESULTS COMPLY WITH SPECIFICATIONS
B. COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS
MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS
D. RETEST