Gibbs Station 1-LR 920617 (4)ALPHA TESTING, INC.
2209 Wisconsin St., Suite 100
Dallas, Texas 75229
(214) 620-8911
REPt OF FIELD
COMPACTION TESTS
TESTED FOR: HEATH & KNIGHT PROPERTIES, INC. DATE:
DALLAS, TEXAS
06/17/92
PROJECT:
GIBBS STATION
LAKES OF COPPELL
COPPELL, TEXAS
OUR REIN)RT NO.
92020-9
TEST DATA:
TEST DATE aOil~ll ~v OCNIITY MOIITUai ~Y II#lITY Pla Cc~ COMMENTe
42 06/17 LFT-1 8 26.8 88.0 28.8 84 96 1-A
43 06/17 LFT-1 3 22.6 92.2 26.6 89 97 1-A
44 06/17 LFT-1 3 22.6 92.2 26.5 90 98 1-A
45 06/17 LFT-1 2 18.2 103.8 19.1 99 95 1-A
46 06/17 LFT-1 2 18.2 103.8 21.5 101 97
47 06/17 LFT-1 3 22.6 92.2 26.9 90 '97 1-A
;48 06/17 LFT-2 8 26.8 88.0 30.0 89 96 1-A
TEST LOCATION: BUILDING PAD
'42 BLOCK C LOT 28 10' $- & 18' E. FROM N.W. CORNER OF PAD
43 8LOCK C LOT 26 18' S. & 22' W. FROM N.E. CORNER OF PAD
44 8LOCK C LOT 7 12' S. & CO' E. FROM N.W. CORNER OF PAD
45 8LOCK C LOT 9 i5' S. & 6' E. FROM N.W. CORNER OF PAD
46 8LOCK C LOT ii 16' N. & i5' E. FROM S.W. CORNER OF PAD
~..----
47 8LOCK C LOT 13 20' N. & 20' E. FROM S.W. CORNER OF PAD
48 BLOCK E LOT i3 22' N. & i5' E. FROM S.W. CORNER OF PAD
1. FILL
2. NATURAL SUBGRADE
3. LIME STABILIZED
4.
A. TEST RESULTS COMPLY WITH SPECIFICATIONS
B. COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS
C. MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS
D. RETEST