Loading...
Gibbs Station 1-LR 920507ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 (214) 620-8911 OF FIELD COMPACTION TESTS TESTED FOR: HEATH & KNIGHT PROPERTIES, INC. DATE: DALLAS: TEXAS 05/07/92 PROJECT: GIBBS STATION LAKES OF COPPELL COPPELL, TEXAS OUR REPORT NO. 92020-7A TEST DATA: r ~'~ - ---- OPTIMUM MAXIMUM LAB IN PLACE IN PLACE TEST DATEf)i~ lOlL ID PiN CENT MOiiTUill OIlY OINIITY MOilTUEI IIY IINIITY COMM[NT· NO. NUMIIN ~ PCP ~ PCP COMPACTION 34 05/07 FG-1 2 18.2 103.8 18.9 102 98 1-A 35 05/07 FG 2 18.2 103.8 19.3 102 98 36 05/07 FG-2 8 26.8 88.0 30.6 86 98 1-A 37 05/07 FG-3 8 26.8 88.0 33.6 84 96 1-A 38 05/07 FG-3 8 26.8 88.0 31.8 86 98 1-A 39 05/07 FG-3 8 26.8 88.0 31.9 86 98 1-A TEST LOCATION: 34 LOT 7 CENTER OF LOT '35 LOT 10 CENTER OF LOT 36 LOT 13 CENTER OF LOT PHASE II 37 LOT 10 8LOCK E 20' N OF S LOT LINE & 40' W OF E LOT LINE PHASE II 38 LOT ? BLOCK E 30' S. OF N. LOT LINE ON CENTER LINE PHASE II 39 LOT i 8LOCK E CENTER OF LOT PHASE II 1. FILL 2. NATURAL SUBGRADE 3. LIME STABILIZED 4. A. TEST RESULTS COMPLY WITH SPECIFICATIONS B. COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS C. MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS D. RETEST