Loading...
Gibbs Station 1-LR 920505 (3)ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas. Texas 75229 (214) 620-8911 REPORT OF FIELD COMPACTION TESTS TESTED FOR: HEATH & KNIGHT PROPERTIES, INC. DATE: DALLAS, TEXAS 05/05/92 PROJECT: GIBBS STATION LAKES OF COPPELL COPPELL, TEXAS OUR REPORT NO. 92020-6A TEST DATA: Tr'ST DAT£ ~l-"rV. loll. ID OPTIMUM iN IBLACII IN PLAC' NO. [ rjjpTfl ~J NUM.III MOl Ulll .... MOlITUlllqb IIY pCpOIENIITYCOMPACTiONP~'II CENT COMM B'NTe 20 05/05 SG 5 13.4 113.5 15.3 112 99 2-A 21 05/05 SG 5 13.4 113.5 14.8 112 99 2-A 22 05/05 SG 9 13.6 114.3 15.2 112 98 2-A 23 05/05 $G 9 13.6 114.3 15.4 110 96 2-A 24 05/05 SG 9 13.6 114.3 15.0 111 97 2-A 25 05/05 SG 9 13.6 114.3 15.0 111 97 2-A 26 05/05 $G 5 13.4 113.5 14.7 112 99 2-A TEST LOCATION: 20 BLOCK C LOT 25 20' N. & 20' E. FROM S.W. CORNER 21 BLOCK C LOT 28 40' N. & 10' E. FROM S.W. CORNER 22 BLOCK C LOT 31 30' N. & 10' ~. FROM S.E. CORNER 23 BLOCK C LOT 34 40' N. & 20' E. FROM S.N. CORNER 24 ~LOCK C LOT 1 10' N. & 20' E. FROM S.W. CORNER 25 BLOCK C LOT 4 40' N. & 40' E. FROM S.W. CORNER 26 50' S. OF STREET $. OF BLOCK E LOT 16 1. FILL 2. NATURAL SUBGRADE 3. LIME STABILIZED 4. A. TEST RESULTS COMPLY WITH SPECIFICATIONS B. COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS C. MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS D. RETEST