Gibbs Station 2-LR 930825 (2) ALPHA TESTING, INC. REPORT OF FIELD
2209 Wisconsin St,, Suite 100
Dallas, Texas 75229 COMPACTION TESTS
(214) 620-8911
TESTEDFOR' GIBBS STATION, LTD DATE: 08/25/93
C/O HEATH & KNIGHT PROPERTIES
DALLAS, TEXAS
PROJECT- GIBBS STATION OURREmRTNO. 93384--11
PHASE II
COPPELL, TEXAS
TEST DATA:
TEST ~ ~ELEV. lOlL 10 OPTIMUM MAXIMUM LAB IN PLACl IN PLiCl
MOIITUNE OaT DINIITY MOIITUIi DRY OENIITY PEru CENT COMMKNTe
NO i DATE r]EPTH ~ N~MBIN ~ PCF ~ PCF COMPACTION
F !
'52 [ 08/25 FG-2.5 7 15.5 109.4 15.9 109 lOG 1-A
i
~53 i 08/25 FG-2.5 7 15.5 109.4 16.9 108 98 1-A
i ',
54 ! 08/25 FG-2.5 7 15.5 109.4 17.0 108 99 I-A
55 08/25 FG-2.5 7 15.5 109.4 17.2 105 96 1-A
TESTLOCATION:
52 SANITARY SEWER LATERAL BACKFILL BLOCK A LOT 18 (LINE "A')
53 SANITARY SEWER LATERAL BACKFILL BLOCK A LOT 12 (LINE "A")
54 SANITARY SEWER LATERAL BACKFILL BLOCK A LOT 8 (LINE "A")
55 SANITARY SEWER LATERAL BACKFILL BLOCK A LOT 5 (LINE "A")
1. FILL ° A. TEST RESULTS COMPLY WITH SPECIFICATIONS Respectfully Submittejl~ A~-
2. NATURAL SUBGRADE B. COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS
3. LIME STABILIZED C. MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS
4. CEMENT TREATED D. RETEST