Loading...
Gibbs Station 2-LR 930824 (4) ' ALPHA TESTING, INC. REPOm OF FIELD //// 2209 wisconsin st., Suite 100 Da,., Tex;s 7522g COMPACTION TESTS (214) 620-8911 TESTED FOR: GIBBS STATION, LTD DATE: 08/24/93 C/O HEATH & KNIGHT PROPERTIES DALLAS, TEXAS PROJECTi GIBBS STATION OUR RmPORT NO. 93384-8 PHASE I I COPPELL, TEXAS TEST DATA: ' ] 1:::{::' 1:::'.:?;'1 'ESTNo ] DATE EL. IV. NUMBERIOIL' lO idOiiTUEEqb D V COMPACTIoNPEa CENT COMMENTe ;6. i 08/24 FG-3 6 13.0 113.9 13.3 110 97 1-A 17 08/24 FG-1 6 13.0 113.9 13.0 109 96 1-A ;8 08/24 FG-3 6 13.0 113.9 13.8 111 97 1-A ;9 08/24 FG-1 6 13.0 113.9 14.4 111 98 1-A .0 08/24 FG-3 17 22.3 95.9 23.5 93 97 1-A .1 08/24 FG-1 17 22.3 95.9 23.2 92 96 1-A .2 08/24 FG-3 5 13.4 113.5 14.2 111 98 i-A -:ST LOCATION: ;6 8" SANITARY SEWER BACKFILL LINE "A" O STA. 7+22 :7 8' SANITARY SEWER BACKFILL LINE "A' O STA. 7+22 r8 8" SANITARY SEWER BACKFILL LINE 'A" ~ STA. 10+30 :9 8" SANITARY SEWER BACKFILL LINE "A' ~ STA. 10+30 .0 8" SANITARY SEWER BACKFILL LINE "A" ~ STA. 12+71 1 8" SANITARY SEWER BACKFILL LINE "A" ~ STA. 12+71 2 8" SANITARY SEWER BACKFILL LINE 'A" · STA. 13+60 FILL ° A. TEST RESULTS COMPLY WITH SPECIFICATIONS ~~~- NATURAL SUBGRADE B. COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS CE~NT T~ATED D. RETEST