Loading...
ST9701-CS 970819August 19, 1997 TO: Larry Davis, Construction Inspector FROM: Avery Rodgers, Streets Division W-~' RE: Inlet Boxes on Lakeshore The following is a survey of subject inlet boxes: 1. Box No. 1, Lakeshore & Crestside - Box fell backward; throat cracked; 18" pipe has bad joint. 2. Box No. 2 - Throat cracked; all that was visible was one bad joint 3 feet into pipe; box looks like it fell. 3. Box No. 3 - Throat severely cracked; one joint has been repaired at some time in the past. 4. Box No. 4 - This box has one of the better throats; 18 inch pipe makes a 45 degree turn, could not get a good picture. 5. Box No. 5 - Box looks as though it fell; throat looks good. 6. Box No. 6 - Throat cracked severely; box seems to have fallen. Included in this packet are video and pictures of the above inlet boxes.