Gibbs Station 2-LR 930813 DI~MIX
ONCRETE)
CONCRETE MIX DESIGN
General: C.W. Young Date: 8113/93
Location: GibDs Station Attn: Larry Davis
Phase I I
Mix# 806 DESIGN SPECIFICATIONS: Per Client Request
Please order by Mix Design Number
28 DAY STRENGTH 4200 PSI
FLY ASH CONTENT: 000
SLUMP: 4"
AGGREGATE SIZE: 1"
ADMIXTURE 23.0
MATERIALS
CEMENT ASTM C150 564
FLY ASH ASTM C618 000
COARSE AGG. 1" Cr. St. 1840
COARSE AGG. 3/8" P.G. 000
Fine Agg. 0-#4 1350
WATER 32.0
ADMIXTURE ASTM C494 23.0
ADMIXTURE ASTM C260 %Air
NOTE: ASTM C-94 Standard Specifications for Ready Mix Concrete "When the concrete strength
is used as a basis for acceptance, the manufacturer shall be entitled to copies of test reports."
"The individual who samples and tests concrete - shall have demonstrated the knowledge and
ability - for Certification, ACI Level I.
To assist in the quality control/quality assurance of your mix, provide reports on a timely basis.
Submitted By: ~~¢_ ~)~ Accepted By:
REDI-MIX, Inc.
GENERAL OFFICE/1445 UacArthur Drive. Suite 136, Carrollton, Texas 75007
PHONE: (234i 242-4550
FAX: (214) 323-0759