Gibbs Station 2-LR 930811 ALPHA TESTING, INC. REPORT OF CONCRETE
22o9 W scons,n St. COMPRESSION TEST
Suite 100
Dallas, Texas 75229
(214) 620-8911
TESTEDFOR GIBBS STATION, LTD DATE: 08/11/93
C/O HEATH & KNIGHT PROPERTIES
DALLAS, TEXAS
PROJECT: GIBBS STATION OURREPORTNO. 93384--2
PHASE II
COPPELL, TEXAS
FIELD DATA
SANITARY SEWER LINE 'B'
LOCATION OF CONCRETE PLACEMENT
STA. 0+00 & STA. 1+63
08/11/93 PLANT 1
DATE PLACED
5 -' 15, DELIVER TICKET NO. 44024
TIME
1 , 5" MIX PROPORTIONS (SSD) N/A
SLUMP
AIR CONTENT N/A CEMENT
AIR TEMPERATURE 98 WATER N/A
CONCRETE TEMPERATURE 95 FINE AGGREGATE N/A
DATE RECEIVED 08/13/93 COARSE AGGREGATE N/A
FIELD DATA SUBMITTED BY DRB ADMIXTURE N/A
MIX DATA SUBMITTED BY REDI-MIX
REMARKS
COMPRESSION
TEST
RESULTS
'~T~' Cylinders made by ALPHA
(NOMINAL CYLINDER SIZE 6- X 12")
representative.
Lab. Customer i Type Date A~e Comprmive 1~_ Cylinders made by Architect's
No. No. [ Curing Tilted Days St~ln~th, Psi or Contractor's representative.
' ylinders picked up by ALPHA
1 933841 LAB 08/18/93 7 i 2750 laboratory.
93384 "
2 ~ LAB 09/08/93 28 4090 [] Cylinders delivered to ALPHA
! , :1 ! laboratory.
3 933841 LAB 09/08/93! 28 4040 [:~-mpression test results comply with
! applicable specifications.
4 93384 LAB HOLD ~ Compression test results do no{ comply
with applicable specifications.
sp~,~,c~,,o-~ 28 4000
TYPE OF FRACTURE, IF OTHER