Loading...
Goodyear-LR 881116 ~ TRINITY ENGINEERING TESTING CORPORATION / TrTco '~ D~l]~s , TEXAS COMPRESSION TESTS TO: Pace Company LTD Limited ~OJECT: Goodyear Service Center 4214 F!uer Drive, Suite 11 Coppell, Texas DesMoines, Iowa 50321 TETCO #1599 Attention: Greg Tieck OATE~ 11/16/88 MADE BY: REPORT NO,: 1188465-JB CONCRETE FOR: Piers CYLINDER MIX SLUMP AGE DATE DATE TOTAL LOAD COMPRESSIVE MARK INCHES DAYS POURED TESTED POUNDS STRENGTH= PSI GC 3 40 10/7/88 11/16/8~ 150,000 5200 4 40 10/7/88 11/16/8~ 151,000 5340 FINE AGG. SOURCE: 28 DAY STRENGTH REOUIREMENT: COARSE AGG. SOURCE: BRAND OF CEMENT; ADDITIONAL INFORMATION IF MADE BY TETCO TIME MADE: UNIT WEIGHT= TRUCK NO.. CONCRETE TEMP.: WATER ADOED TO TRUCK= TICKET NO.: AIR CONTENT: ACCUMULATED YARDS: WEATHER ', RE MARKS: .",*TTES I,)CC, MPRESSI',,E STRENGTHS EETERMIhED tN ~,ECORDAh£E WITH A$'T.M C3,9 [2) CROSS-SECTIONAL AREA, DIAMETER AND LENGTH ARE STANDARD UhiLESS OTHER'~SE NOTED '~,~. PORTIOhS OF THE INFORMATIOn,, CONTAINED IN THIS RE. PORT HAVE BEEN FURNISHED BY OTHERS (4) CYLINDERS CURED I. LABORATOR'I IN ACCORDAhCE WITH A S TM C~,, UN,~_ESS OTHERWISE NOTED CO~IES TO: 2-Above 1-Pace Company, LTD Limited fi~'i:t ention: Jack Randle ~..~City of Coppetl ~?RINIT¥ £NGIN££RING T£$TIN{.~ ~ORPORATION Attention: Steve Martin