Gibbs Station 2-CS 930429 6. The church should pursue the acquisition of right-of-way from the property to the west so that they can access Samuel Blvd., thereby gaining access to the signalized intersection at Samuel and MacArthur Blvd. for north bound vehicles. The current drive configurations do not align with the existing median at the southern property line, therefore traffic headed north bound on MacArthur will need to make a U-turn at the intersection of Lake Forest and MacArthur Blvd. 7. There has been some discussion about if a deceleration lane is needed. As has previously been stated, a traffic study should be performed to determine if the deceleration lane will be required. 4. Round Oak Estates Final Plat - located along the west side of Harris Road, 120 feet north of Dakota Lane. The Engineering Department offered no comments concerning this final plat. Any comments concerning this will be addressed during the review of the construction plans. 5. Creekview Phase H located at the northeast and southeast corner of Bethel School Road and Denton Tap Road. This was initially reviewed on April 29th and the following comments were offered: 1. Minimum finished floors should be shown on all lots. 2. A tree survey should be provided as requested by the Planning and Zoning Commission. 3. The access easement through Lot 3, intersecting Denton Tap at the southern boundary line of Lot 3 and the access easement to the property to the south should be shown on the plat. A revised plat was provided at the May 6th meeting. The revised plat showed the minimum finish floors and the access easement along the southern property line of Lot 3. However, it did not show the 24 foot access easement to the property to the south, therefore the Engineering Department offers the following comments: 1. The 24 foot access easement to the property to the south should be shown on the plat. 6. Gibbs Station Phase II Final Plat - located along the east side of MacArthur Blvd. near Village Parkway. April 29, 1993 Comments: 1. All easements should be shown on the plat. 2. The property in the floodplain, on Lots 14-35, Block E should be included as part of the Homeowners Association, not part of the private lots. Also, access to that common area should be provided. 3. The floodway should be labeled. 4. The master plan shows a future 30" sewer line along the southern property line between MacArthur and Village Parkway. If MUD is satisfied that the current 27" is sufficient, then a letter should be provided from the MUD District. May 6th, 1993 Final Comments: 1. The floodway behind Lots 14-35, Block E should be labeled Floodplain/Floodway. 2. The note concerning the variable width floodplain/floodway easement should be revised as noted at the DRC meeting. 3. A letter is still required from the MUD District concerning the existing 27" MUD line between MacArthur Blvd. and Village Parkway. 7. Georgetown Plaza Shopping Center. 1. Sidewalks along Samuel Blvd. should be constructed. 2. Some type of agreement should be worked out between St. Ann's Catholic Church and the City of Coppell to allow access across the existing paved surface along the northern part of this property when needed during the construction of Sandy Lake Road. 3. Escrow for Sandy Lake Road should be paid if that has not already been paid with the initial platting of the property. Staff is currently researching the issue. 8. Heartz Road Elementary School Final Plat (Town Center Elementary School). 1. Escrow and/or an escrow agreement should be executed for the schools responsibility for the future construction of the street along the west side of the property for the ring road.