Loading...
Grand Cove-CS 940405 MEMORANDUM To: Taryon Bowman, Planning and Zoning Coordinator From: Kenneth M. Griffin, P.E., Assistant City Manager/City Engineer RE: Engineering Comments for April 7, 1994 Date: April 5, 1994 1. White Glove Express Addition, Preliminary Plat. located along the east side of Denton Tap Road, 500 feet south of Braewood Lane, at the request of Mr. Lelmy Poulsen. 1. The existing 15 foot utility easement on the south side of the property should a minimum 20 foot in width. 2. The 10 foot utility easement on the east side of the property should be eliminated. 3. The 5 foot utility easement on the north side of the property should be labeled as to its usage. 4. A drainage easement should be provided for the proposed storm drainage system. Also, the offsite drainage area should be revaluated. 2. ~:;** ....... "~'~'"'n~'~ii~'- ....... ~Final Plat. located along the south side of Bethel ~' ~:, g;.~.,~q~"~egf-51' Denton Tap Road, at the request of Mr. Frank Bamberg. 1. All easements should be shown. 2. All variance requests should be on the face of the plat 3. All minimum finished floors should be shown. 4. The floodplain should be tied down by metes and bounds description. Also, note that the minimum easement between lots 4 and 5 should be 20 feet. 5. The standard maintenance note should be shown on the face of the plat.