CONCRETE INSPECTION AND COMPRESSION TEST REPORT
DISTRIBUTION:
CLIENT: North American Communities Archon Group - Angie Rawe
PROJECT: Karrington Apartments North American Conmaunities - Kurt Heinbecker
REPORT DATE: 12728100 C.D. Construction - Garreth Campbell
TMI REPORT #: DC00-040-106 CiR' of Coppell - Greg Jones
SPECIFICATIONS PROJECT DATA
Strength (psi): 4000 Placement Date: 11/30."00
Slump ('in.): 5 -;- 1 Sampled By: A. Haves
Air Content (%): 4 -..'-2 Weather: Sunny: Nice
Concrete Temp (°F): I00 Supplier-Mix: TXI ' 8272
FIELD DATA: SET #1
Ticket ~: 2'785841 Time Batched: 10:47 AM Time Sampled: 1:18 PM
Slump (in.): 6 Air Content (%): 5 Unit Weight (pcf):
Conc. Temp. I?F): ~ Ambient Temp. (°F): 6.---' Yardage (c.y.): 12 of 12
Placement Location: Paving at Club House Parking Area
Sample Location: Center portion of Paving at Club House Parking
Remarks:
CONCRETE COMPRESSION TEST RESULTS
CYLINDERS MOLDED AND CURED PER ASTM C31. TESTED PER ASTM C39. CAPPED PER ASTM C123t
Set # Age Max Load Strength
Cylinder # Test Date Area (sq.in) Notes
1 (Days) (lbs) (psi)
113001 12/7,'00 7 110150 28.27 3900
113002 12/28/00 28 141180 28.27 4990
113003 12/28/00 28 153340 28.27 5420
KAR
113004 Discard
~1 ~ NORMAL CYI_INDER SIZE 6" X 12". AREA 28.27 sq. in., UNLESS NOTED ABOVE.
~2'~ UNBONDED CAP SYSTEM USED UNLESS OTHERWISE NOTED ABOVE.
(31 FIELD TESTS .\RE PER APPI.ICABLE ASTM STANDARDS: C!3g. Cia_L C,'. 72. C231