Gunner P2-LR001002 TERI~.k-MAR, INC.
GEOTECHNICAL ENVIRONMENTAL AND MATERIALS ENGINEERS
DALLAS FORT WORTH HOUSTON LONGVIE~t/ AUSTIN
11050 Ables Lane, Dallas. Texas 75229 Phone.'972-488-8800 Fax.'972-488-8080
CONCRETE INSPECTION AND COMPRESSION TEST REPORT
DISTRIBUTION:
CLIENT: North American Communities Archon Group - Angie Rawe
PROJECT: Karrington Apartments North American Communities - Kurt Heinbecker
REPORT DATE: 10.2.O0 C.D. Construction - Garreth Campbell
TMI REPORT #: DC00-040-094 CiD' ofCoppell - Greg Jones
SPECIFICATIONS PROJECT DATA
Strength (psi): 3000 Placement Date: 9;1-'00
Slump (in.): 1 - 4 Sampled By: C. Kalu
Air Content t'%I: N A Weather: Clear
Concrete Temp (=F): ~ Supplier. Mix: TX][
FIELD DATA: SET #1
Ticket #: 2725381 Time Batched: 5:40 AM Time Sampled: 6:35 AM
Slump {in.): 4_ Air Content ¢%): N-A L'nit Weight Ipcfl: N.-'A
Conc. Temp. !:F'): 97 Ambient Temp. (°F): 88 Yardage ~c.y.): ~
Placement Location: Garage Foundation
Sample Location: Interior of grade beams at NE corner of Garage D
Remarks:
CONCRETE COMPRESSION TEST RESULTS
t'YLINI)ERS MOLDED .AND ('L REI) PER AS-I'M C3i, TESTED PER .-\STM C30. C..\PPED PER ..\S'FM C122
Set # Age Max Load Strength
Cylinder" Test Date Area (sq.in) Notes
1 (Days) (lbs) (psi)
0901 ()1 9,' 8,"00 7 81060 28.27 2870
090102 9."29..."'00 28 103660 28.27 3670
090103 9.'29.."00 28 102880 28.27 3640
KAR
090104 Discard
~ l ~ NORMAL CYLINDI:I~t SIZE 0" X ~ 2". AREA 28.2? .-.q.m.. UNLESS NC)TED ABOVE.
~2) UNBONDED CAP SXr'q'l'l~M t SED UNLESS OTi!ERWISE NOTED ABOVE.
!3) FIELD TESTS .-\RE I'!:R .-\I'I'!.!('.\BLE ASTM ST.\ND.\RDS CI3~. ('143, £'172. C231
sd Gar~ D Dry,
Page 1 of I CME Manager - Dallas
Note: This report is for the exclusive use of the client addressed. This report may not be reproduced except in its
entirety, without the written consent of TMI. Results apply only to above tests.