Loading...
Gunner P2-LR000920 (2) - TERRA-MAR, INC. - GEOTECHNICAt., ENVIRONMENTAL AND MATERIALS ENGINEERS DALLAS FORT WORTH HOUSTON LONGI"IEIV .4L:STIN 11050.4hies Lane. Dallas. Texas 75229 Phone:972-488-8800 Fax:972-488-8080 CONCRETE INSPECTION AND COMPRESSION TEST REPORT DISTRIBUTION: CLIENT: North American Communities Archon Group - Angle Rawe PROJECT: Karrington Apartments North American Communities - Kurt Heinbecker REPORT DATE: 9 20:00 C.D. Construction - Garreth Campbell TMI REPORT #: DC00-040-099 City.' of Coppell - Greg Jones SPECIFICATIONS PROJECT DATA Strength (psi): 3000 Placement Date: S-15 '00 Slump (in.): "- ~ Sampled By: M. Yahvazadeh Air Content (%): N A Weather: Clear Concrete Temp I ~F): 85 to 95 Supplier:Mix: TXI FIELD DATA: SET #1 Ticket ~': N. A Time Batched: N.'A Time Sampled: N:A Slump (in.): N-A Air Content (%): N:A Unit Weight ipct): N.:A Cone. Temp. i ~F): N A Ambient Temp. (~-F): N:A Yardage ~c.y. ): N:A Placement Location: West side of Building Sample Location: West .side of Building ~9 Remarks: CONCRETE COMPRESSION TEST RESULTS ("(LINl)ER.q MOLDED AND CURED ?ER ASTM (_'~!. TESTED PER ASTM ("3'). C,\PPED PER ASTM C123i Set 44 Age Max Load Strength Cylinder :-'? Test Date Area (sq.in) Notes 1 (Days) (lbs) (psi) 081501 8/22/00 -' 108450 28.27 3840 081502 9/12/00 28 147860 28.27 5230 081503 9/12;00 28 141930 28.27 5020 KAR 081504 Discard il ~ NORMAL CYI.INDIiR SIZE o" X ;2". AREA 28.2? sq. :n.. UNLESS NOTED ABOVE. (2) L'NBONDED CAP SYS FE*I USED UNkESS OTHERWISE NOTED ABOVE (3~ FIELD TESTS ARE I'LR .\P!'I_I('.xBLE ASTM STANDARDs: ('128. ('243. C~72. C231 ~d Gar3' D. Dry, Page 1 of I CME Manager- Dallas Note: This report is for the exclusive use of the client addressed. This report may not be reproduced except in its entirety, without the written consent of TMI. Results apply only to above tests.