Gunner P2-LR000630 (2) TERRA-MAR, INC.
GEOTECHNICAL ENVIRONMENTAL AND MATERIALS ENGINEERS
DALLAS FORT'WORTH HOUSTON LONGVIEW AUSTIN
11050 Ables Lane. Dallas'. Texas 75229 Phone:972-483-8800 Fcrx:972-488-8080
CONCRETE INSPECTION AND COMPRESSION TEST REPORT
DISTRIBUTION:
CLIENT: North American Communities Archon Group - .~ngie Rawie
PROJECT: Karrmgton Apartments North .-M-nerican Communities - Kurt Heinbecker
REPORT DATE: 6/30/00 C.D. Construction - Garreth Campbell
TMI REPORT #: DC00-040-022 City. ofCoppell - Greg Jones
SPECIFICATIONS PROJECT DATA
Strength (psi): ,N/.~, Placement Date: ~/19/00
Slump (in.): N,'A Sampled By: Contractor
Air Content (%): N,.'X, Weather: N/A
Concrete Temp (°F): N;'A Supplier/Mix: N/A
FIELD DATA: SET # 1
Ticket ~: N,'A Time Batched: ,N,',A Time Sampled: N,"A
Slump (in.): N'3 Air Content {%): N,A Unit Weight (pcf}: N/A
Cone. Temp. (°F): N/A Ambient Temp. (°F): N;A Yardage (c.y.): N;'A
Placement Location: Inlet
Sample Location:
Remarks: Cylinders made and information furnished bv contractor.
CONCRETE COMPRESSION TEST RESULTS
CYLINDERS MOLDED AND CURED PER ASTM C31, TESTED PER ASTM C39, CAPPED PER ASTM C617
Set # Age Max Load Area Strength
1 Cylinder # Test Date (Days) (lbs) (sq.in) (psi) Notes
051901 5/26/00 7 97480 28.09 3470
051902 6/16/00 28 121340 28.37 4280
051903 6/16/00 28 119610 28.37 4220
KAR
051904 Discard
(I) NOI~MAL CYLINDER SIZE O" X 12". AREA 28.2' sq. :n., UNLESS NOTED ABOVE.
(2) U.'NBONDED CAP SYSTEM USED, TYPE A~CONE: F~-kCTL RE UNLESS OTHERWISE NOTED: B ~CONE-SPLIT); C(CONE-SHEAR.); D
(SHEAR); E iCOLUMNAR}
(3) FIELD TESTS ARE PER APPLICABLE ASTM STANDARDS: C138. C]43. C172. C23i
Additional Distribution:
Don Matlock - Fax: 972-906-0608
,d Gary D. Dry., |
Page I of' ! Project Manager
Note: This report is for the exclusive use of the client addressed. This report may not be reproduced except in its
entirety, without the written consent of TMI. Results apply only to above tests.