Loading...
Hollows-LR 990504 (2) REPORT OF FIELD COMPACTION TESTS ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 972/620-8911 - 972/263-4937 (Metro) FAX: 972/406-8023 TESTED FOR N L W DEVELOPMENT GROUP DATE 5/4199 DALLAS, TEXAS PROJECT HOLLOVVS ~} NORTHLAKE WOODLAND OUR REPORT NO. 99128-57A COPPELL, TEXAS TEST DATA: TEST ~ ELEV. SOIL ID OPTIMUM MAX]MUM LAB IN PLAC~ IN PLACE PERCENT NO. DATE 7PTH~ NUMBER MOISTURE DRY D~[NSITY MOIS'rURE DRY DENS~I'Y COMPACTION COMMENT* 835 5~4~99 FG-2.0 1 26.8 92 29. 9 100 108 1 -A 836 5/4199 FG-1.0 I 28.8 92 27.8 91 99 1-A 837 5/4/99 FG I 26.8 92 27.3 92 100 1-A 838 5/4/99 FG-9.0 I 26.8 92 28.3 91 99 1-A 839 5/4~99 FG-8.0 1 26.8 92 29.1 89 97 1-A 840 5/4/99 FG-7.0 I 26.8 92 27.7 92 100 1-A 841 5/4/99 FG-6.0 1 26.8 92 29.6 90 98 1-A TEST LOCATION: 835 SANITARY SEWER SERVICE - BLOCK B, PAD 3 836 SANITARY SEWER SERVICE - BLOCK B, PAD 3 837 SANITARY SEWER SERVICE - BLOCK B, PAD 3 838 SANITARY SEWER SERVICE - BLOCK .B, PAD 7 839 SANITARY SEWER SERVICE - BLOCK B, PAD 7 840 SANITARY SEWER SERVICE - BLOCK B, PAD 7 841 SANITARY SEWER SERVICE - BLOCK B, PAD 7 FILL ~ A. IN PLACE PERCE'NT MQt~FURE AND PIERCENT COMPACTION COMPLY WITH SPECIFICATIONS NATURAL SUBGRADE B. PERC~I~Fr COMPACTION DOES NOT COMPLY WITH ~PIEClFICATION~ R~I~if Subl~~ UM~ ST^B~Z~D C. "~.CENT-- "~CE MO~TU.~ DOES.OT COMPLY W~H CEME~ITTREATED D. RETEST ~ ALPHA T~ Geotechnicol Engineedr~ · Construction Materials Testing · Envfronmental Engineedr~ · Consulting