Hollows-LR 990430 REPORT OF FIELD
COMPACTION
TESTS
ALPHA TESTING, INC.
2209 Wisconsin St., Suite 100
Dallas. Texas 75229
972/620-8911 - 972/263-4937 (Metro)
FAX: 972/406-8023
TESTED FOR N L W DEVELOPMENT GROUP DATE 4/30/99
DALLAS, TEXAS
PROJECT HOLLOWS @ NORTHLAKE WOODLAND OUR REPORT NO. 99128-§6
COPPELL, TEXAS
TEST DATA:
TEST ~ ELEV. SOIL ID OPTIMUM MAXJMUM LAB IN PLACE IN PLACE PERCEN1
NO. DATE DEPTH ~,~ NUMBER MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMPACTION COMMENT
% PCF % POI:
816 4/30/99 FG-5.0 2 24.3 95.2 27.4 91 95 1 -A
817 4/30/99 FG-4.0 2 24.3 95.2 26.9 91 96 1 -A
818 4/30/99 FG-3.0 2 24.3 95.2 25.3 92 97 1 -A
819 4/30/99 FG-2.0 2 24.3 95.2 24.3 93 98 1-A
820 4/30/99 FG- 1.0 2 24.3 95.2 24.7 93 98 1 -A
821 4/30/99 FG 2 24.3 95.2 25.1 95 1 O0 1 -A
822 4/30/99 FG-5.0 2 24.3 95.2 24.7 95 99 1-A
TEST LOCATION:
816 SANITARY SEWER LINE E AT STATION //15+00
817 SANITARY SEWER LINE E AT STATION //15+00
818 SANITARY SEWER LINE E AT STATION #15+00
819 SANITARY SEWER LINE E AT STATION //15+00
820 SANITARY SEWER LINE E AT STATION #15+00
821 SANITARY SEWER LINE E AT STATION //15+00
822 SANITARY SEWER LINE E AT STATION //18+00
FILL # A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS
NATURAL SUBGRADE R. PERCENT COMPACTION DOES NO1 COMPLY W,TH SPEC,F,CAT,ONS R~speg[~y Submitte~ /
LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS
Geotechnical Engk~efing · Construc~ Materk~s Testing · Environmental Englnee#ng · Consulting