Loading...
Hollows-LR 990430 REPORT OF FIELD COMPACTION TESTS ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas. Texas 75229 972/620-8911 - 972/263-4937 (Metro) FAX: 972/406-8023 TESTED FOR N L W DEVELOPMENT GROUP DATE 4/30/99 DALLAS, TEXAS PROJECT HOLLOWS @ NORTHLAKE WOODLAND OUR REPORT NO. 99128-§6 COPPELL, TEXAS TEST DATA: TEST ~ ELEV. SOIL ID OPTIMUM MAXJMUM LAB IN PLACE IN PLACE PERCEN1 NO. DATE DEPTH ~,~ NUMBER MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMPACTION COMMENT % PCF % POI: 816 4/30/99 FG-5.0 2 24.3 95.2 27.4 91 95 1 -A 817 4/30/99 FG-4.0 2 24.3 95.2 26.9 91 96 1 -A 818 4/30/99 FG-3.0 2 24.3 95.2 25.3 92 97 1 -A 819 4/30/99 FG-2.0 2 24.3 95.2 24.3 93 98 1-A 820 4/30/99 FG- 1.0 2 24.3 95.2 24.7 93 98 1 -A 821 4/30/99 FG 2 24.3 95.2 25.1 95 1 O0 1 -A 822 4/30/99 FG-5.0 2 24.3 95.2 24.7 95 99 1-A TEST LOCATION: 816 SANITARY SEWER LINE E AT STATION //15+00 817 SANITARY SEWER LINE E AT STATION //15+00 818 SANITARY SEWER LINE E AT STATION #15+00 819 SANITARY SEWER LINE E AT STATION //15+00 820 SANITARY SEWER LINE E AT STATION #15+00 821 SANITARY SEWER LINE E AT STATION //15+00 822 SANITARY SEWER LINE E AT STATION //18+00 FILL # A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS NATURAL SUBGRADE R. PERCENT COMPACTION DOES NO1 COMPLY W,TH SPEC,F,CAT,ONS R~speg[~y Submitte~ / LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS Geotechnical Engk~efing · Construc~ Materk~s Testing · Environmental Englnee#ng · Consulting