Loading...
Hollows-LR 990422 REPCRT OF FIELD COMPi CTION TESTS ALPHA TESTING, INC. 220~ Wisconsin St.. Suite I00 Dallas, Texas 7522~ 972/620-8911 - ~72/263-4~37 (Metro) FAX: 972/406-8023 TESTED FOR N L W DEVELOPMENT GROUP DATE 4/22/99 DALLAS, TEXAS PROJECT HOLLOWS (~} NORTHLAKE WOODLAND OUR REPORT NO. 99128-52 COPPELL, TEXAS TEST DATA: TEST ELEV. SOIL ID oP'nMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT NO. DATE DEPTH NUMBER MOISTURE DRY DENSi'FY MOIS'RJRE DRY ~NsrrY CO.AC'nON COMMENT* % PCF % PCF 757 4/22/99 FG-9.0 2 24.3 95.2 ;~5.9 93 97 1-A 758 4/22/99 FG-8.0 2 24.3 95.2 25.5 92 97 1-A 759 4/22/99 FG-7.0 2 24.3 95.2 25.7 92 96 1-A 760 4122/99 FG-6.0 2 24.3 95.2 27.1 91 95 1-A 761 4/22/99 FG-5.0 2 24.3 95.2 26.4 92 96 1-A 762 4/22/99 FG-4.0 2 24.3 95.2 25.4 92 97 1-A 763 4/22/99 FG-3.0 2 24.3 95.2 26.3 91 95 1-A TEST LOCATION: 757 SANITARY SEWER SERVICE TO BLOCK B, PAD 1 758 SANITARY SEWER SERVICE TO BLOCK B, PAD 1 759 SANITARY SEWER SERVICE TO BLOCK B, PAD 1 760 SANITARY SEWER SERVICE TO BLOCK B, PAD 1 761 SANITARY SEWER SERVICE TO BLOCK B, PAD 1 762 SANITARY SEWER SERVICE TO BLOCK B, PAD 1 763 SANITARY SEWER SERVICE TO BLOCK B, PAD 1 1. FILL a.A. IN PLACE I:~CEN'T MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS ~~'~ ~ 2. NATURAL SUBGRADE B. PERCENT COMPACI~,,~ DOES NOT COMP[.YWlTH SPEClFICA'I'K)NS R 3. LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS 4. CEMENT TREATED D. RE'rEST Geotechntc~ E~ · ~ Materials Tes#ng · Environmental Engineering · Consu~