Hollows-LR 990417 REPORT OF FIELD
COMPACTION TESTS
ALPHA TESTING, INC.
2209 Wisconsin St., Suite 100
Dallas, Texas 75229
972/620-8911 - 972/263-4937 (Metro)
FAX: 972/406-8023
TESTED FOR N L W DEVELOPMENT GROUP DATE 4/17/99
DALLAS, TEXAS
PROJECT HOLLOWS (J~ NORTHLAKE WOODLAND OUR REPORT NO. 99128-45
COPPELL, TEXAS
TEST DATA:
TEST '~ ELEV. SOIL ID OrmMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT
NO. DATE DEPTH-'~ NUMBER MOISTURE DRY DENSITY MO[STI. IRE ORY OENSITY COMPACTION COMMENT*
% PCF % PCF
689 4/17/99 FG-9.0 3 23.2 98.2 25.5 95 97 1-A
690 4/17/99 FG-8.0 3 23.2 98.2 · 24.5 97 99 1-A
691 4117/99 FG-7.0 3 23.2 98.2 25.9 96 98 1-A
692 4117/99 FG-6.0 3 23.2 98.2 26.1 96 97 1-A
693 4/17/99 FG-5.0 3 23.2 98.2 27.0 94 96 1-A
694 4/17/99 FG-4.0 3 23.2 98.2 26.3 95 97 1 -A
695 4/17/99 FG-3.0 3 23.2 98.2 24.9 96 98 1-A
TEST LOCATION:
689 SANITARY SEWER SERVICE TO BLOCK B, PAD 1
690 SANITARY SEWER SERVICE TO BLOCK B, PAD 1
691 SANITARY SEWER SERVICE TO BLOCK B, PAD 1
692 SANITARY SEWER SERVICE TO BLOCK B, PAD 1
693 SANITARY SEWER SERVICE TO BLOCK B, PAD 1
694 SANITARY SEWER SERVICE TO BLOCK B, PAD 1
695 SANITARY SEWER SERVICE TO BLOCK B, PAD 1
FILL * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS
NATURAL SUBGRADE B. PERCENT COMPACI~ON DOES NOT COMPLY W/TH SPECIFICA~ONS
lIME STABILIZED C. PERCENT IN PLACE ~RE DO~S NOT COMPLYWlTH SPECIFICATIONS
CEMENT TREATED D. RETEST
Geotechnk:~ Engtneefk~ · ~flon IVk]ferk:~ Testing · Environmental Engineering · Consulting