Hollows-LR 990412 REPORT OF FIELD
COMPACTION TESTS
ALPHA T£STING, INC.
2209 Wisconsin St., Suite 100
Dallas, Texas 75229
972/620-8911 - 972/263-4937 (Metro)
FAX: 972/406-8023
TESTED FOR N L W DEVELOPMENT GROUP DATE 4/12/99
DALLAS, TEXAS
PROJECT HOLLOWS ~} NORTHLAKE WOODLAND OUR REPORT NO. 99128-38
COPPELL, TEXAS
TEST DATA:
TEST '~. ELEV. SOIL ID O~MUU MAXIMUM LAB IN PLACE IN PLACE PERCENT
NO. DATE DEPTH'~ NUMBER MOISTURE DRY OEI~St'I~MOISTURE DRY O{~srrY CO~PAC'nO~ COMMENT*
% PCF % PCF
615 4/1 2/99 FG-3.0 I 26.8 92 29.7 89 96 1 -A
616 4/1 2/99 FG-2.0 I 26.8 92 30.6 88 96 1 -A
617 4/12/99 FG-1.0 1 26.8 92 30.0 89 96 1-A
618 4/1 2/99 FG I 26.8 92 26.0 91 ,99 1-A
619 4/12/99 FG-2.0 I 26.8 92 28.3 90 98 1-A
620 4/12/99 FG-1.0 I 26.8 92 27.9 90 98 1-A
621 4/1 2/99 FG I 26.8 92 28.7 89 97 1-A
TEST LOCATION:
615 STORM SEWER LINE A AT STATION #15+00
616 STORM SEWER LINE A AT STATION #15+00
617 STORM SEWER LINE A AT STATION #15+00
618 STORM SEWER LINE A AT STATION #15+00
619 STORM SEWER LINE A AT STATION #17+00
620 STORM SEWER LINE A AT STATION #17+00
621 STORM SEWER LINE A AT STATION #17+00
FILL ar A. IN PLACE PERCENT MOISTURE AND PERCENT COMPA~ COMPLY WITH SPECIFICATIONS
NATURAL SUBGRADE B. PERCENTCOMPACTICN DOES NOT COMPLY 'WITH SPECIRCATIONS Respectfully Submitted
UME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS
CEMENT TREATED D. RL~'Em' ALPHA TESTING, INC.
Geo~ E~ · ~ Materk~s Te~g · Env~:~nto/ Eng~ee~ng · Cor'~fing